TERALANI 2

TERALANI 2 is a 2000 passenger vessel (inspected). The Coast Guard has recorded 53 inspections since 2000, most recently in April 2026, along with 87 deficiencies, 3 operational controls and 4 casualty investigations between 2015 and 2023.

Records from 2000 to 2026. Most recent: inspection, 9 April 2026.

Built
2000
Last inspected
9 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDA2147
Flag
UNITED STATES
338380000
Maury page id
psix-12212

Inspections, by type

…with no type recorded5
Years with a record 24 calendar years (2000–2026)
The 53 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)65.0 ft × 34.0 ft × 8.7 ft
Registered tonnagegross 49 / net 39
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMULTIHULL TECHNOLOGIES INC · KEY WEST, FL, UNITED STATES · built 2000
Hull materialFRP (Fiberglass)
PropulsionAuxiliary Sail
Hull shapeNot recorded
Hull configurationTwin Hull
Hailing portKEY WEST, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 1 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it39 - Simplified, Net Ton
49 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL7860MMSI 338380000 · active · compulsorily equipped · granted 29 September 2020, expires 29 September 2030
WDA2147MMSI 338380000 · cancelled · compulsorily equipped · granted 18 August 2010, cancelled 24 January 2020
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MEGALODON Passenger (Inspected) · MISLE 1326074 · 10 November 2023 · activity 7831742TERALANI 3 Passenger (Inspected) · MISLE 735661 · 11 September 2015 · activity 5725220

Inspection history · 53

9 April 2026 In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8345716
8 October 2025 COI Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8245959
9 September 2025 In-Service Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8233113
4 December 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8042974
10 September 2024 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7999834
26 June 2024 In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7942858
9 January 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7847171
10 November 2023 Examination of Repairs · Damage Survey · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7826503
10 November 2023 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7831742
23 October 2023 Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7813352
29 June 2023 In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7756873
15 February 2023 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7637042
2 December 2022 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7600745
29 June 2022 In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7484708
14 January 2022 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7379010
7 August 2021 Deficiency Check · Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7280149
27 April 2021 Internal Structural Exam · In-Service Inspection · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7157731
13 April 2021 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7180102
14 October 2020 Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7070002
4 May 2020 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6948074
14 November 2019 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6855912
4 November 2019 Administrative Inspection · Deadweight Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6849249
4 October 2019 Administrative Inspection · Annual Inspection · In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6928427
16 August 2019 In-Service Inspection · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6785645
2 November 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6573686
9 February 2018 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6352859
26 January 2018 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6345892
22 January 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6342551
11 October 2017 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6286011
15 September 2017 Internal Structural Exam · Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6282393
22 November 2016 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6048930
13 November 2015 DAPI Audit · Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5762667
27 September 2015 Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5766355
11 September 2015 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5725220
13 January 2012 Annual Inspection · DAPI Audit · Deficiency Check · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4224463
27 July 2011 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4096282
22 November 2010 COI Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3896474
2 March 2010 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3688500
10 March 2009 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3430965
19 February 2008 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3149782
6 September 2007 Hull Examination · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3050189
7 June 2007 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2967178
23 January 2007 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2860510
15 November 2005 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2534657
11 October 2005 Hull Examination · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2557384
12 January 2005 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2299082
21 May 2004 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2088720
26 November 2003 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1955083
11 December 2002 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1726755
15 October 2002 Internal Structural Exam
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1694550
21 March 2002 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1495796
30 October 2001 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1376785
6 October 2000 Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1462902

Deficiency record · 87

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 October 2025 Resolved
Adjust the port side remote fuel shutoff pull so that it completely closes the port fuel shutoff valve.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 October 2025
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 8 October 2025 Resolved
Provide a visual indicator for the starboard bilge high level alarm.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2025
Resolved 28 October 2025
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 8 October 2025 Resolved
Provide a functioning FCC accepted general marine radar system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2025
Resolved 28 October 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 October 2025 Resolved
Provide a valid FCC Safety Radio Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2025
Resolved 28 October 2025
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 September 2025 Resolved
Conduct post mast inspection sea trials with the mainsail raised prior to carrying passengers under sail.
Action required: 705 - Other - as specified
Resolved 15 September 2025
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 September 2025 Resolved
Provide a rigging invoice with all components replaced or updated rigging inventory with install dates.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2025
Resolved 23 September 2025
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 December 2024 Resolved
Demonstrate operation of the power driven fire pump prior to carrying more than 49 passengers.
Action required: 705 - Other - as specified
Resolved 5 December 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 December 2024 Resolved
Demonstrate operation of the fixed bilge pump for the starboard side hull prior to carrying more than 49 passengers (fire pump serves as bilge pump).
Action required: 705 - Other - as specified
Resolved 5 December 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 December 2024 Resolved
Demonstrate the capability to dewater the port forward space prior to carrying more than 49 passengers.
Action required: 705 - Other - as specified
Resolved 5 December 2024
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 4 December 2024 Resolved
Provide a suitable radar display prior to carrying more than 49 passengers.
Action required: 705 - Other - as specified
Resolved 9 December 2024
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 December 2024 Resolved
Provide a suitable electronic chart display or updated paper charts of the local area
Action required: 705 - Other - as specified
Resolved 9 December 2024
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 4 December 2024 Resolved
Provide a public address system or bullhorn for making public announcements from the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 December 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 December 2024 Resolved
Mount the 10-B:C portable fire extinguisher at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 December 2024
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 4 December 2024 Resolved
Post a Garbage Management placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 December 2024
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 4 December 2024 Resolved
Post a life jacket donning placard visible to passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 December 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 December 2024 Resolved
Post the Certificate of Inspection and Stability Letter or a sign saying they are available upon request.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 December 2024
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 January 2024 Resolved
A FCC Type Accepted Category 1, 406 MHz EPIRB is required on board. The EPIRB's registration and battery were both expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 January 2024
Resolution: A new EPIRB was purchased, registered, and installed on the vessel. Def cleared
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 9 January 2024 Resolved
A visual and audible bilge high level alarm is required in the port and starboard engine rooms. The bilge high level alarms were tested and did not provide a suitable visual or audible alarm. Provide satisfactory bilge high level alarms.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 January 2024
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 9 January 2024 Resolved
A self priming, power driven fire pump is required on board. The installed fire pump could not be properly tested due to potential clutch failure. Diagnose and test fire pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 January 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 9 January 2024 Resolved
Provide dogs for the portlight dead cover in the port head to make the cover weathertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 January 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 January 2024 Resolved
Remove or properly enclose all dead end wiring in the port and starboard heads.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 January 2024
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 9 January 2024 Resolved
Install guards to prevent accidental contact with the rotating machinery (belts) in the port and starboard engine rooms.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 January 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 January 2024 Resolved
The nonmetallic piping material (hose) used in the fuel return line for the starboard engine is not approved for use on this vessel. Replace with approved metallic piping or approved flexible nonmetallic hose meeting SAE J-1942.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 January 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 November 2023 Resolved
Vessel suffered a loss of propulsion on its starboard engine while transiting outbound on an afternoon snorkel trip. Diagnose issue, complete repairs, and conduct sea trials.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 November 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 October 2023 Resolved
Received report suffered a loss of propulsion when attempting to get underway following a snorkel trip. Vessel was still at anchor when engine failed. Captain saw smoke in the engine room and manually discharged pre-engineered fixed gas fire extinguishing system. Diagnose cause of engine failure and source of smoke and make permanent repairs, and conduct sea trials.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 October 2023 Resolved
Service pre-engineered fixed gas fire extinguishing system and conduct shutdown and reset test.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2023
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 14 January 2022 Resolved
Vessels must have 01 2-A portable fire in concessions, galley, and/or pantry areas. Vessel does not have fire extinguisher in concession area required by COI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2022
Resolved 21 January 2022
Resolution: Vessel provided new fire extinguisher in galley.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 August 2021 Resolved
Propulsion machinery must be suitable in type and design form propulsion requirements of the hull. Vessel suffered a marine casualty which made the starboard transmission inoperable. Vessel rep must provide information on the extent of the damage, a scope of work for repair, and prove proper operation of the starboard propulsion system prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2021
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 14 October 2020 Resolved
Could not provide logs showing daily/weekly rigging inspections have been conducted in accordance with vessel’s preventative maintenance plan. Provide documentation showing all Captains have been instructed on the requirement to log daily/weekly inspections. 46 CFR 176.840
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 October 2020
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 October 2020 Resolved
Post life jacket donning instructions in a conspicuous place that is accessible and visible to crew and passengers. 46 CFR 185.516
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 October 2020
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 14 October 2020 Resolved
EPIRB registration lists previous owners as emergency points of contact. Update EPIRB registration with current emergency points of contact. 46 CFR 180.64
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 October 2020
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 October 2020 Resolved
Provide updated up-to-date chart for safe navigation in operating area. 46 CFR 184.420(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 October 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 October 2020 Resolved
10-B:C portable fire extinguisher located at the operating station has external corrosion on the top and bottom. Replace with new 10-B:C portable fire extinguisher. 46 CFR 181.500
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 October 2020
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 18 March 2020 Resolved
Vessel's Chain plate fasteners in way of the starboard forestay and port shroud show severe signs of corrosion. Additionally, fiberglass cracking in way of starboard forestay chainplate raises concerns about entire rigging system. Third Party Rigging Survey must be completed to the satisfaction of the OCMI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 March 2020
Resolved 28 April 2020
Communications › Radio Communications › EPIRB
Issued 22 January 2018 Resolved
Epirb battery and hydrostatic release are expired. Renew in accordance with 46CFR 180.64. Vessel is limited to within 3 miles of shore.
Action required: 705 - Other - as specified
Resolved 9 February 2018
Resolution: E-pirb and hydro static release renewed.
Engineering › Steering Gear System › Motor
Issued 6 October 2017 Resolved
Vessel needs to complete satisfactory sea trials under motor power witnessed by an attending USCG Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 October 2017
Resolved 11 October 2017
Resolution: Vessel conducted satisfactory sea trials under motor power with an attending USCG Marine Inspector.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 13 November 2015 Resolved
smoke activated fire detection system must be operable in all required spaces
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2015
Resolution: repaired system detectors.
Communications › Alarms/Indicators › Bilge Alarm
Issued 13 November 2015 Resolved
Bilge pump visual auto indicators not operating properly
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2015
Resolution: Installed new control board
Navigation › Piloting/Steering › US Coast Pilot
Issued 13 November 2015 Resolved
Missing Coast Pilot and CG Light list
Due 20 November 2015
Resolved 14 November 2015
Resolution: Printed Coast Pilot and CG Light list
Communications › Alarms/Indicators › Fire Alarm
Issued 13 November 2015 Resolved
Audible Alarm for fixed gas fire fighting system not operating properly.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2015
Resolution: Audible Alarm for fixed gas fire fighting system replaced.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 13 November 2015 Resolved
Reto tape needs replaced on various jackets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2015
Resolution: Life jacket reto tape was replaced on various
Communications › Alarms/Indicators › High Water Alarm
Issued 13 January 2012 Resolved
Provide high water alarms in port and stbd rudder compartments.
Action required: 705 - Other - as specified
Due 20 January 2012
Resolved 17 January 2012
Construction/Loadline › Structures › Superstructure
Issued 13 January 2012 Resolved
Repair port and stbd forestay chain plates. Vessel restricted from using sails until complete.
Action required: 705 - Other - as specified
Resolved 16 February 2012
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 11 September 2011 Resolved
Replace 3/8" elongated shackle used to secure swim platform with appropriate size/strength hardware.
Due 20 September 2011
Resolved 13 September 2011
Navigation › Piloting/Steering › Compass Deviation Table
Issued 2 March 2010 Resolved
Provide compass deviation table.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 April 2010
Resolved 26 March 2010
Construction/Loadline › Structures › Superstructure
Issued 2 March 2010 Resolved
Repair fractured crossbeam flange sleeve starboard fwd.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 March 2010
Resolved 15 March 2010
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 10 March 2009 Resolved
PROVIDE MEANS FOR SECURING THE MSD OVERBOARD DISCHARGE VALVE.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2009
Resolved 21 April 2009
Fire Fighting › Combustible Materials › Partial Bulkheads/Decks
Issued 10 March 2009 Resolved
PROVIDE NON COMBUSTIBLE PANNELS FOR THE ENGINE ROOM OVERHEAD &INBOARD SIDES.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 April 2009
Resolved 21 April 2009
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 March 2009 Resolved
PROVIDE MACHINERY GUARDS FOR BELT ASSEMBLYS ON BOTH PORT AND STARBOARD SIDES.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 April 2009
Resolved 21 April 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 March 2009 Resolved
UPDATE FIRST AID KIT (ASPRIN)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2009
Resolved 21 April 2009
Lifesaving › Lifefloat › Float-free Link
Issued 10 March 2009 Resolved
RENEW STBD. SIDE WEAK LINK.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2009
Resolved 21 April 2009
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 10 March 2009 Resolved
PROVIDE REPAIR PROPOSAL FOR CRACKED FRAME IN PORT FWD SPACE.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 April 2009
Resolved 21 April 2009
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 10 March 2009 Resolved
INSTALL PRESSURE GUAGE ON LPG COOKING SYSTEM.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 April 2009
Resolved 21 April 2009
Lifesaving › Lifefloat › Lifeline
Issued 10 March 2009 Resolved
REPAIR OR RENEW PORT LIFEFLOAT.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2009
Resolved 21 April 2009
Construction/Loadline › Structures › Superstructure
Issued 10 March 2009 Resolved
CRACKED BOOM SUPPORT BEAM AT HELM STATION.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 April 2009
Resolved 17 March 2009
Resolution: Attended vessel in Lahaina Harbor and inspected repair. Repair was satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 September 2007 Resolved
Mount machinery guards on port & stbd engines (alternator)
Due 1 October 2007
Resolved 10 March 2009
Engineering › Diesel Engine (propulsion-electric) › Block
Issued 25 September 2007 Resolved
Re-route throttle cables and mount (cables currently routed over engine and secured by wire tie to bolt on engine block)
Due 1 October 2007
Resolved 10 March 2009
Electrical › Electric Supply System (service) › Cable
Issued 6 September 2007 Resolved
Secure loose wiring in fwd port hull and ensure compliance with 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 25 September 2007
Resolved 25 September 2007
Construction/Loadline › Penetrations › Valve Flange
Issued 6 September 2007 Resolved
Renew/replace thru hull fitting located in port side head.
Action required: 705 - Other - as specified
Resolved 25 September 2007
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 6 September 2007 Resolved
Fill all vacant holes in engine room bulkheads and make vaportight.
Action required: 705 - Other - as specified
Resolved 25 September 2007
Stability › Watertight Integrity › General
Issued 6 September 2007 Resolved
Fill and make watertight hole in fuel tank space fwd bulkhead
Action required: 705 - Other - as specified
Resolved 25 September 2007
Engineering › Diesel Engine (propulsion-electric) › Block
Issued 6 September 2007 Resolved
Conduct operational tests of new engines in the presence of USCG Marine Inspector
Action required: 705 - Other - as specified
Due 25 September 2007
Resolved 25 September 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 January 2007 Resolved
Renew Batteries for Waterlights.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 January 2007
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 23 January 2007 Resolved
Renew lifelines on stantions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 January 2007
Lifesaving › Lifefloat › Painter
Issued 23 January 2007 Resolved
Renew painter launcher for stbd lifefloat.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 January 2007
Stability › Severe Wind/Roll › General
Issued 23 January 2007 Resolved
Renew fractured terminal fitting at bottom of rod rigging section of lower shroud on both port and stbd sides.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 January 2007
Engineering › Bilge Water Management System › Pump
Issued 23 January 2007 Resolved
Prove satisfactory operation of bilge pumps.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 January 2007
Lifesaving › Lifefloat › Painter
Issued 23 January 2007 Resolved
Renew weak link on port lifefloat.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 January 2007
Engineering › Fuel Oil Service System › Filter
Issued 23 January 2007 Resolved
Provide solid plugs for bottom of racor fuel filters.
Due 23 February 2007
Resolved 23 February 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 23 January 2007 Resolved
Replace all non metallic cable supports with metallic supports.
Due 23 February 2007
Resolved 23 February 2007
Engineering › Freshwater System (jacketwater cooling) › Reciever
Issued 23 January 2007 Resolved
Prove high water temp gauge on stbd side.
Due 23 February 2007
Resolved 23 February 2007
Engineering › Bilge Water Management System › Piping
Issued 23 January 2007 Resolved
Remove PVC patch on port bilge system and renew as original.
Due 23 February 2007
Resolved 31 January 2007
Engineering › Fuel Oil Service System › Valve
Issued 23 January 2007 Resolved
Adjust emergency fuel shut off valves so that they close all the way.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 January 2007
Stability › Watertight Integrity › Weathertight Enclosure
Issued 23 January 2007 Resolved
Repair of renew as original the port side forward deck hatch.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 January 2007
Engineering › Bilge Water Management System › Piping
Issued 23 January 2007 Resolved
Comply with 46 CFR 182.710 conserning bilge piping. (No PVC allowed)
Due 23 February 2007
Resolved 23 February 2007
Engineering › Bilge Water Management System › Piping
Issued 23 January 2007 Resolved
Prove all bilge piping junctions/couplings. Inspector noted loose connection points for bilge piping.
Due 23 February 2007
Resolved 23 February 2007
Stability › Severe Wind/Roll › General
Issued 23 January 2007 Resolved
Complete a professional rigging survey at the next credit drydock.
Action required: 705 - Other - as specified
Due 31 October 2007
Resolved 17 February 2009
Fire Fighting
Issued 30 October 2001 Resolved
Provide structural fire fighting IAW 46CFR177.410 NLT 7NOV01.
Condition: Unknown
Due 31 December 2001
Resolved 21 March 2002
Resolution: Witnessed installation and operational test of smoke alarm system. Tested SAT.
Lifesaving
Issued 30 October 2001 Resolved
No life line for life ring buoy. Provide line IAW 46CFR180.70(C) NLT 7NOV01and prior to carrying passengers.
Condition: Unknown
Due 7 November 2001
Resolved 12 December 2001
Fire Fighting
Issued 30 October 2001 Resolved
Missing one B-II portable fire extinguisher (one was a B-I rather than a B-II). Provide one additional B-II portable fire extinguisher prior to carrying passengers and NLT 7NOV01.
Condition: Unknown
Due 12 December 2001
Resolved 12 December 2001
Accommodation/Occupational Safety
Issued 30 October 2001 Resolved
Various items missing from first aid kit. Outfit kit IAW 46CFR184.710 & 160.041 NLT 7NOV01.
Condition: Unknown
Due 7 November 2001
Resolved 12 December 2001
Fire Fighting
Issued 30 October 2001 Resolved
Port and starboard fixed fire fighting systems are too small for the space intended. Provide system of adequate size and capacity IAW 46CFR181.400_x001C_ and 181.420 NLT 21NOV01.
Condition: Unknown
Due 12 December 2001
Resolved 12 December 2001
Fire Fighting
Issued 30 October 2001 Resolved
Doors to port and stbd engine rooms and wire runs holes in bulkheads prevented the spaces from being vapor tight. Make port and starboard enginerooms vapor tight IAW 46CFR181.400 NLT 7NOV01.
Condition: Unknown
Due 12 December 2001
Resolved 12 December 2001
Navigation
Issued 30 October 2001 Resolved
Provide CG light list or excerpt IAW 46CFR184.420 NLT 7NOV01.
Condition: Unknown
Due 7 November 2001
Resolved 12 December 2001
Lifesaving
Issued 6 October 2000 Resolved
Conducte emergency drills to the satisfaction of the cognizant OCMI.
Condition: Unknown
Due 12 December 2001
Resolved 12 December 2001
Lifesaving
Issued 6 October 2000 Resolved
Develop emergency procedures for man overboard & fire. Procedures shall bevessel specific and include fixed fire system, procedures for sails(s).
Condition: Unknown
Due 6 October 2000
Resolved 6 October 2000
Accommodation/Occupational Safety
Issued 6 October 2000 Resolved
To the satisfaction of the cognizant OCMI, mark the following: a) Locationand # of PFDs; b) Emergency Fuel Shutoffs; c) PFD Donning Procedures; _x001C_ d) Radio Emergency Broadcase & MARPOL Placards
Condition: Unknown
Due 7 November 2001
Resolved 21 December 2001

Casualty record · 4

11 September 2015Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 5725220
26 January 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 6345892
13 April 2021Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7180102
10 November 2023Routine · role: Involved in a Marine Casualty · activity 7831742
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.