Records from 2007 to 2026. Most recent: inspection, 27 May 2026.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 May 2026
Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Station license expired. Provide copy of current FCC Station License. 46 CFR 184.502
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2026
Resolved 1 June 2026
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 April 2025
Resolved
The design, materials, and construction of masts, posts, yards, booms, bowsprits, and standing rigging on a sailing vessel must be suitable for the intended service. Aft aluminum plate section of the forward port support for vessel crossbeam worn and wasted. Requires renewal and review from 3rd party surveyor to better determine severity. 46 CFR 177.330
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2025
Resolved 11 June 2025
Resolution: Worn plate renewed on crossbeam support
09 - Working and Living Conditions › 092 - Working Conditions › Other (mooring)
Issued 30 April 2025
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks. Starboard forward samson post corroded and showing signs of wastage. Requires renewal. 46 CFR 176.802(a)(1)
Action required: 705 - Other - as specified
Due 30 November 2025
Resolved 14 October 2025
Resolution: Extension request approved. After 11/30/2025 deficiency turns into 701. New samson post installed, exact same dimensions, material is stainless. Weight difference negligible, under 10lbs. Observed no further damage to surrounding structure or fiberglass.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 30 April 2025
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection and operation of all weathertight closures above the weather deck. Port and starboard portlight and hatches wasted, missing backing plates, closures and seals. Damaged Hatches and portlights require renewal in accommodation/head space. 46 CFR 176.802(a)(6)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2025
Resolved 11 June 2025
Resolution: cabin hatches and port and starboard portlights renewed
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 April 2025
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station: A means to reset devices used to automatically shut down ventilation systems and engines as required by paragraph (a)(3) of this section. Starboard Fireboy override switch not operating. Bridge panel replaced during inspection and operationally tested. All sat. 46 CFR 181.420(b)(3)
Action required: 10 - Deficiency Rectified
Resolved 30 April 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 April 2025
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. Vessel required to modify BBQ to include jettison device per Sector Honolulu work instruction 46. Submit repair plans to OCMI for approval. Vessel will follow all other action steps required in part 5 of work instruction 46 and also all "best practice" details stated in company Letter/SOP as a means of mitigating fire risk. 46 CFR 176.700(a)
Action required: 705 - Other - as specified
Due 30 November 2026
Resolved 16 January 2026
Resolution: 16JAN2026: Submitted Open Flame Grilling Policy approved IAW Sector Honolulu Work Instruction 46. Attached to vessel documents.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 May 2024
Resolved
The following spaces must be equipped with a fixed gas fire extinguishing system in compliance with 181.410: A space containing propulsion machinery. Fireboy for port engine room discharged during testing. Replace with charged system and demonstrate all shutdowns, alarms, and overrides to the attending USCG marine inspector.
46 CFR 181.400 (a)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2024
Resolution: Replaced Fireboy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 May 2024
Resolved
A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment. Strainers must be leak free. Strainers must be the type of opening on top for cleaning screens. A drip pan fitted with flame screen must be installed under gasoline strainers. Fuel filter and strainer bowls must be highly resistant to shattering due to mechanical impact and resistant to failure due to thermal shock. Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. Approval of bowls of other than steel construction will specify if a flame shield is required. Vessel did not have a metal bowl installed in starboard side engine room.
46 CFR 182.455 (b)(6)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2024
Resolved 14 May 2024
Resolution: Metal fuel bowl installed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 May 2024
Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessel is missing burn gel in first aid kit.
46 CFR 184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2024
Resolved 14 May 2024
Resolution: Burn gel provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 May 2024
Resolved
The owner shall be prepared to conduct tests and have the vessel ready for inspection of the following: On a sailing vessel all spars, standing rigging, running rigging, blocks, fittings, and sails. Vessel's reef outhaul line worn due to chafing.
46 CFR 176.802 (a)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2024
Resolved 2 May 2024
Resolution: Replaced line.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 2 May 2024
Resolved
In systems and applications where flexible hoses are permitted to be clamped: Double hose clamping is required where practicable. Missing double hose clamps on stbd bilge lazarette.
46 CFR 182.410 (d)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2024
Resolved 14 May 2024
Resolution: Double hose clamps provided.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 2 May 2024
Resolved
Each unpressurized fuel tank must be fitted with a vent pipe connected to the highest point of the tank. Fuel tank vent line not attached to fuel tank.
46 CFR 182.450 (a)
Action required: 10 - Deficiency Rectified
Resolved 2 May 2024
Resolution: Properly reattached fuel tank vent line.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 2 May 2024
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Pie eye cover in forward port side compartment missing.
46 CFR 176.830 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2024
Resolved 14 May 2024
Resolution: Cover provided for port side compartment.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 August 2023
Resolved
The design, materials, and construction of masts, posts, yards, booms, bowsprits, and standing rigging on a sailing vessel must be suitable for the intended service. The mast deck step center pin has multiple areas of pitting. Clean and fill pitting prior to re-installing the mast. 46CFR177.330
Action required: 705 - Other - as specified
Resolved 31 August 2023
Resolution: Areas of pitting satisfactorily addressed with epoxy coating.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 28 June 2023
Resolved
Each ship transporting more that six passengers for hire equipped with a radiotelephone station must carry a radio operator who: holds a marine radio operator permit (MROP) or higher class license. Master onboard did not have a valid radio operator permit. Provide master with valid MROP.
47 CFR 80.158 (e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2023
Resolved 11 July 2023
Resolution: MROP provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 June 2023
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2023
Resolved 11 July 2023
Resolution: Employee list for drug testing provided.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 28 June 2023
Resolved
Firefighting drills and abandon ship drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: Date of the drill and training; and general description of the drill scenario and training topics. Vessel unable to provide logs for fire fighting and abandon ship drills and training. Provide log book entries.
46 CFR 185.524(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2023
Resolved 11 July 2023
Resolution: Drill log provided.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 28 June 2023
Resolved
A vessel on a limited coastwise route must carry six hand red flare distress signals and six hand orange smoke signals. A red hand flare distress signal may be substituted for any of the hand orange smoke distress signals. Vessel's hand orange smoke distress signals are expired. Vessel missing 01 distress signal. Provide distress signals in order to meet the regulation. Vessel restricted to a Lakes/Bays/Sounds route or 30 min runs.
46 CFR 180.68
Action required: 705 - Other - as specified
Resolved 11 July 2023
Resolution: Distress signals provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 June 2023
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Bilge pump indicator at helm not operational. Provide visual indicator for bilge pump.
46 CFR 182.530(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2023
Resolved 5 July 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 June 2023
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge opening for a space protected by a fixed gas extinguishing system. Vent closure was not operational. Provide operational vent closures for engine room.
46 CFR 182.465(i)
Action required: 17 - Rectify deficiencies prior to departure
Due 28 July 2023
Resolved 28 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 June 2023
Resolved
All engines must have at least two means for stopping the engine under any operating conditions. Stopping engine from the operating station was not operational. Provide ability to stop engine.
46 CFR 183.200(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2023
Resolved 11 July 2023
Resolution: Engine stop operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 June 2023
Resolved
The owner shall be prepared to conduct tests and have the vessel ready for inspection of the following: On a sailing vessel all spars, standing rigging, running rigging, blocks, fittings, and sails. Vessel does not have evidence of annual furler removal in accordance with preventative maintenance plan to adequately assess the safe condition of their sail rigging system in accordance with USCG NVIC 02-16. Operator shall provide evidence of furler disassembly, or complete disassembly of furler. Furler not to be used until evidence of disassembly provided or furler is dissembled and documented.
46 CFR 176.802 (a)(3)
Action required: 705 - Other - as specified
Resolved 7 July 2023
Resolution: Furler disassembled and logged in PMP.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 March 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to provide safe service under normal and emergency conditions, protect passengers and crew from electrical hazards including fire and shock, accidental contact with energized parts, and prevent electrical ignition of flammable vapors. Vessel renewed electrical wiring per original approved plan but did not complete the installation due to parts delay. Vessel restricted from passenger carrying service until electrical installation is completed.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2023
Resolved 18 March 2023
Resolution: Electrical installation completed IAW approved plans.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 May 2022
Resolved
Sail Rigging Preventative Maintenance Plan (PMP)must be onboard vessel at all times. PMP not currently on vessel and not currently updated. Provide full rigging inventory of all old and new rigging components, inspections, and rigging details. Ensure all to log all inspections in accordance with vessel PMP. Keep copy of PMP on board vessel at all times and submitted revised version of PMP to [name withheld] 02-16
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2022
Resolved 28 September 2022
Resolution: PMP provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 May 2022
Resolved
Installation of portable fire extinguisher must be in accordance with manufacture. Extinguisher not placed in bracket. Provide bracket for lower forward fire extinguisher.
46 CFR 181.520
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2022
Resolved 23 August 2022
Resolution: Bracket provided.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 31 May 2022
Resolved
The discharge of untreated sewage is prohibited within 3 miles from shore for a type 3 device. Sewage overboard valve must be locked within 3 miles from shore. Sewage overboard valve in the open position and not locked. Provide lock for sewage valve.
33 CFR 159.7
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2022
Resolved 12 June 2022
Resolution: Locks provided for sewage.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 May 2022
Resolved
Vessel must have permanent loading marks placed on each side of the vessel forward and aft to indicate the maximum allowable trim and amidships to indicate the maximum allowable draft.
A loading mark must be a horizontal line of at least 8 inches in length and 1 inch in height, with its upper edge passing through the point of maximum draft. The loading mark must be painted in a contrasting color to the sideshell paint. Loading marks not on vessel. Provide loading marks in accordance with your stability letter and communicate with MSC to ensure exact location. Stability letter may need updated to provide these marks.
Completed at next drydock in Nov 2022.
46 CFR 185.602
Action required: 705 - Other - as specified
Resolved 30 November 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 May 2022
Resolved
Electrical equipment must be installed and maintained to provide services necessary for safety under normal circumstances. Stop button at helm for port engine not operational. Provide operational stop button.
46 CFR 183.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2022
Resolved 23 August 2022
Resolution: Stop button operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 November 2021
Resolved
Inspection of all railings and bulwarks and their attachment to the hull structure. Forward hand rail support bases on the crossbeam are corroded due to stainless steel bolt securing the post and also excessively worn.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 December 2021
Resolved 16 November 2021
Resolution: New crossbeam supports welded on.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 November 2021
Resolved
Inspection of the condition of the superstructure, masts, and similar arrangements constructed on the hull, and on a sailing vessel all spars, standing rigging, running rigging, blocks, fittings, and sails. Stbd inner stay base mount screwhead sheared off.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 December 2021
Resolved 16 November 2021
Resolution: New screw installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 November 2021
Resolved
Inspection of the condition of the superstructure, masts, and similar arrangements constructed on the hull, and on a sailing vessel all spars, standing rigging, running rigging, blocks, fittings, and sails; Forward ingress ladder head bolt securing the ladder from the wing is backing off and backing plate is corroded.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 December 2021
Resolved 16 November 2021
Resolution: New backing plate and bolt installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 November 2021
Resolved
Inspection of all railings and bulwarks and their attachment to the hull structure. All handrail underdeck support backing plates corroded; replace all as needed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 December 2021
Resolved 16 November 2021
Resolution: New backing plates installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 November 2021
Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. Positive and negative posts for two batteries have wing nuts for the anchor windlass.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 November 2021
Resolved 16 November 2021
Resolution: Nuts provided.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 8 July 2021
Resolved
National Merchant Mariners must hold an unexpired medical certificate or submit a medical application. Master did not have medical certificate at inspection. Provide medical certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2021
Resolved 6 November 2021
Resolution: Medical cert provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 July 2021
Resolved
FCC Safety Radio Certificate not on board. Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with 47 CFR 80.59 once every five years. Provide valid FCC Safety Radio Certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2021
Resolved 15 November 2021
Resolution: FCC Doc provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 July 2021
Resolved
Alcohol swabs/testing expired. A marine employer whose vessel is involved in a casualty shall comply with 46 CFR 4.06. Provide valid alcohol swabs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2021
Resolved 15 November 2021
Resolution: Alcohol test kit provided.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 July 2021
Resolved
Numerous hand red flares and orange smoke distress signals expired. Vessel shall have 6 and 6 of each hand red flare and orange smoke distress signals. Provide proper amount of valid distress signals
Action required: 10 - Deficiency Rectified
Resolved 8 July 2021
Resolution: Distress flares provided.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 8 July 2021
Resolved
01 life float light not operational. Life float light must be operational IAW 161.010. Provide operational life float light.
Action required: 10 - Deficiency Rectified
Resolved 8 July 2021
Resolution: Operational light provided.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 8 July 2021
Resolved
Aft engine room bulkhead penetration leading to tunnel was not able to secure. This increases the size/volume of the engine room making the pre-engineered fixed firefighting system Cubic Footage not able to cover increased area. Provide closure device for bulkhead penetration to ensure proper firefighting capability IAW “Fire Boy” manufacture specifications.
Action required: 10 - Deficiency Rectified
Resolved 8 July 2021
Resolution: Penetrations secured.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 July 2021
Resolved
Fire buckets missing lanyards. Bucket to be attached with lanyard that is long enough to get water from ocean while standing on deck. Provide lanyards for fire buckets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2021
Resolved 29 July 2021
Resolution: Fire buckets with lanyard provided.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 July 2021
Resolved
Missing 01 independent modular smoke detector in each head. To maintain consistency throughout vessel fleet built with non-fire retardant resign place 01 fire detector in each head and submit a request for special consideration for fire independent modular smoke detection in place of a smoke activated fire detection system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2021
Resolved 26 July 2021
Resolution: Modular smoke detector provided for each head.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 8 July 2021
Resolved
08 automatic bilge pump indicators not operational at helm. A visual indicator must be provided at the helm when any automatic bilge pump is operating. Provide auto bilge indication at the helm. Complete and log rounds of all spaces every 15 minutes until system is operational.
Action required: 705 - Other - as specified
Resolved 23 September 2021
Resolution: Auto bilge pump indicators operational.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 8 July 2021
Resolved
Inspection cover in chain locker missing making open bulkhead penetration. Provide inspection cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2021
Resolved 26 July 2021
Resolution: Inspection cover provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 July 2021
Resolved
Starboard intermediate shroud/inner forestay chain plate showing corrosion and 01 bolt sheared off/no nut. Sail rigging must be suitable for intended service. Make repairs, clean area, corroded bolts, nuts, chain plate, install new bolt and nut and make ready for inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2021
Resolution: Bolts and nuts removed. Chain plate cleaned and new hardwear installed.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 8 July 2021
Resolved
Approximately 20 inch cracks on deck on both sides of traveler. The hull structure must be adequately reinforced to ensure sufficient strength. Remove paint for expanded inspection of deck cracking.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2021
Resolved 15 November 2021
Resolution: Cracks repaired.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 July 2021
Resolved
Former fire protection system controls at helm/different from current system. Remove old fire protection system controls that is no longer in use from helm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2021
Resolved 26 July 2021
Resolution: Old system removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 July 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2021
Resolved 16 November 2021
Resolution: Engine room area coverage plan submitted and approved.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 8 July 2021
Resolved
Forward railing loose/mounted in cups that allow for large amount of give. Deck rails must be constructed to withstand a point load 0f 200 lbs. Make railings secure and not give.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2021
Resolved 28 July 2021
Resolution: Rail supported with botls and gaskets.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 8 July 2021
Resolved
Remote fuel shutoff valve marking covered by fabric in head. Marking shall be visible to passengers and crew. Provide markings that are not covered.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2021
Resolved 28 July 2021
Resolution: Fuel shutoff markings no visable.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 July 2021
Resolved
Jib/Roller furler cracked. Sail rigging must be suitable for intended service. Remove cracked jib/roller furler and replace.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 July 2021
Resolved 10 July 2021
Resolution: 3rd party sail rigger noted damaged furler on last inspection, and oted that it was not a structural crack. Still requiring replacing furler within 14 days.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 July 2021
Resolved
Unknown the last time Jib/Roller furler was disassembled to inspect forestay. Sail rigging must be suitable for intended service. Remove jib/roller furler and make forestay ready for inspection or provide documentation IAW company PMP that shows forestay inspection was completed within specified period.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 July 2021
Resolution: Furler removed for visual inspection of rigging. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 July 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2021
Resolved 29 September 2021
Resolution: Updated PMP provided.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 8 July 2021
Resolved
Port side collision bulkhead has penetrations where old ladder was positioned. Collision bulkhead must not be fitted with any type of penetrations. Make permanent repairs to bulkhead by sealing penetrations with fiber reinforced plastic FRP/Fiberglass.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2021
Resolved 28 July 2021
Resolution: Penetrations filled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 July 2021
Resolved
Band clamps missing on fuel fill starboard side and port engine room bilge overboard hoses. 02 clamps required on each flexible hose on each side of hose. Provide 02 band clamps on each side of the hoses.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2021
Resolved 26 July 2021
Resolution: Band clamps provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 July 2021
Resolved
Flammable materials (West System Epoxy) on board. Diesel fuel being stored in gasoline jugs. Flammable materials shall be stored in a paint locker/steel box or removed from vessel. Diesel shall be stored in appropriately marked diesel yellow jugs/or diesel fuel tank.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2021
Resolved 26 July 2021
Resolution: Flammables removed.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 8 July 2021
Resolved
Sewage valves missing lock. Secure overboard sewage valves (closing each valve leading to an overboard discharge/removing the handle; padlock each valve in the closed position; or using a non-releasable wire-tie to hold each valve leading to an overboard discharge in the closed position).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2021
Resolved 26 July 2021
Resolution: Sewage valves locked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 July 2021
Resolved
Port/starboard side rudder rams leaking oil into bilge and both rudder systems have loose fittings. Steering system must be maintained in such a manner to afford adequate protection from failure. Make repairs to rams to prevent oil leaks and ensure all fittings are tight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2021
Resolved 28 July 2021
Resolution: Rams tightened.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 July 2021
Resolved
Battery capacity is not enough to raise anchor in safe amount of time. Anchor windless takes more power than batteries/inverter can provide. Provide safe and effective means for raising anchor. If more batteries or larger inverter needed provide updated electrical plans to the Marine Safety Center for review and approval.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2021
Resolved 29 July 2021
Resolution: Anchor windless operational.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 16 February 2021
Resolved
Update Company Drug Policy/Paperwork to reflect current changes to DAPI program (i.e., Provide EAP information; SAP information; Hot-line information, etc).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2021
Resolved 15 March 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 February 2021
Resolved
The Designated Employee Representative (DER) should be executing the notification process to employees for completion of DOT Random Drug Tests.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2021
Resolved 8 March 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 February 2021
Resolved
Establish record system as discussed during DAPI Audit. Provide MIS reports for 2016 and 2018. Ensure record system is secured and organized in DER office.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2021
Resolved 8 March 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 February 2021
Resolved
Provide Letter of Regulatory Compliance (LORC) for Reliable Drug Testing Services Consortium.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2021
Resolved 8 March 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 February 2021
Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and the employer's supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. Provide proof of completed EAP training for all personnel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2021
Resolved 15 March 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 January 2021
Resolved
Alterations to equipment that affect the safety of the vessel must not be made without OCMI approval in accordance with 46 CFR 176.700. Vessel water tank configuration does not match approved plans. Submit plans for approval or reconfigure vessel to original plans dated 24 Dec 2008. Unauthorized 55 gal tanks in port/stbd forward compartment and 95gal tanks in port/stbd rudder compartments are to be drained and fills capped to prevent use.
6 Jan 2021 - Tanks now drained and fills capped.
Resubmit plans for approval or reconfigure vessel to original plans dated 24 Dec 2008. Requiring update on plan review status every 14 days. CG-835 amended to show code 16. If plan review takes longer than 14 days a request for extension of this CG-835 shall be submitted and reviewed.
06 Jan 202-[name withheld]
12 Jan 2021 - Aft tank removed. Forward tanks still in place and capped. MSC Plan Approval Process in place. Code 16 still open. Require updates on plan review every 14 days.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2022
Resolution: Plans submitted to and examined by MSC.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 May 2020
Resolved
Survival craft float free links must be permanently attached to vessel in accordance with 46 CFR 180.130. Life floats float free links were not connected to vessel.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2020
Resolved 27 May 2020
Resolution: Float free links attached during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 May 2020
Resolved
Vessel required 6 red flares and 6 smoke flares in accordance with 46 CFR 180.68. 6 red flares and 4 smoke flares were provided. Vessel short 2 smoke flares.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2020
Resolution: 2 smoke flares provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 May 2020
Resolved
Preventative Maintenance Plan is required for sailing vessels in accordance with 46 CFR 176.840. Rigging Preventative Maintenance Plan was not provided.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2020
Resolved 3 June 2020
Resolution: PMP provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 May 2020
Resolved
Alterations to equipment that affect the safety of the vessel must not be made without OCMI approval in accordance with 46 CFR 176.700. Vessel water tank configuration does not match approved plans. Submit plans for approval or reconfigure vessel to original plans dated 24 Dec 2008. Unauthorized 55 gal tanks in port/stbd forward compartment and 95gal tanks in port/stbd rudder compartments are to be drained and fills capped to prevent use.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 August 2020
Resolved 27 April 2022
Resolution: Plans submitted and examined by MSC.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 March 2019
Resolved
Vessel is required to have navigation lights in accordance with 46 CFR 183.20. Stbd running light was extinguished. Vessel limited to day light operations only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 March 2019
Resolution: Stbd running light repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 17 July 2018
Resolved
Survival craft arrangements. Painter weak link capacity exceeds lifefloats.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2018
Resolution: Weak links replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 17 July 2018
Resolved
Distress flares. Vessel has 4 smoke and 4 red flares.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 July 2018
Resolution: Flares provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 July 2018
Resolved
Ring bouy lifeline. Lifeline was missing lifeline.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 July 2018
Resolution: Lifeline for ring buoy provided.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 July 2018
Resolved
Proper operation of system. Green ready light was extinguished on stbd engine compartment. Prove satisfactory operation of dampners for both engine compartments.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 July 2018
Resolution: Fixed extinguishing system serviced by certified third party. Stbd ready light was repaired and dampner function verified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 July 2018
Resolved
Engine exhaust cooling. Port propulsion engine muffler was patched with epoxy.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 September 2018
Resolution: Muffler renewed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 July 2018
Resolved
Bilge high level alarms. Stbd fwd compartment bilge alarm was not operational.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 July 2018
Resolution: Stbd fwd compartment bilge alarm repaired.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 17 July 2018
Resolved
Requirements of the FCC. Radio Safety Certificate was not provided.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 July 2018
Resolution: Radio Safety Cert provided.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 17 July 2018
Resolved
Requirements of the FCC. Current e-pirb registration was not provided.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 July 2018
Resolution: E-pirb registration provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 July 2018
Resolved
Material inspection, hull. Accesses in port and stbd watertight bulkheads aft of collision bulkhead are not watertight.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 September 2018
Resolution: Accesses made sufficiently watertight via sealed/bolted plates.
Operations/Management › Drills/Instruction › Not Conducted
Issued 15 May 2018
Resolved
Vessel needs to complete satisfactory sea trials under sail propulsion witnessed by an attending USCG Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2018
Resolved 17 May 2018
Resolution: Sail trial witnessed by surveyor [name withheld] on behalf of the Coast Guard.
Engineering › Bilge Water Management System › Pump
Issued 10 May 2017
Resolved
Stbd side midship bilge pump not in bracket.
Due 10 May 2017
Resolved 10 May 2017
Resolution: Pump bracket moved and pump installed.