Records from 2007 to 2026. Most recent: inspection, 4 March 2026.
Inspection history · 23
4 March 2026
COI Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8319603
20 May 2025
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8139493
23 April 2025
Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8118152
13 March 2025
Administrative Inspection
Administrative · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8098892
18 April 2024
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7897307
18 October 2023
Deficiency Check · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7810350
18 April 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7670646
12 October 2022
Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7576690
6 June 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7469593
21 April 2021
Drydock Exam · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7178738
1 April 2021
COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7166639
7 July 2020
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6999767
18 June 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6980602
27 September 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6822793
12 July 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6751351
24 April 2019
Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6682029
12 June 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6442848
3 November 2017
Administrative Inspection · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6302655
16 October 2017
Administrative Inspection · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6288862
31 July 2017
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6226858
27 June 2017
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6181010
31 May 2016
DAPI Audit · Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5842361
16 May 2016
Administrative Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5913829
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 April 2023
Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. Port running light was inoperable. Provide navigation lights that are in compliance with the Navigation Rules prior to taking passengers.
46 CFR 183.420
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 April 2023
Resolution: New nav light installed and operational.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 April 2023
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Bilge pump indicator for mid starboard space at helm not operational. Provide visual indicator when auto bilge pump is in use prior to taking passengers.
46 CFR 182.530(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 April 2023
Resolution: New indicator installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 April 2023
Resolved
Vessel must be provided with satisfactory arrangement for draining any watertight compartment. Vessel was unable to demonstrate operation of the mid starboard space electric bilge pump. Prove proper operation of the mid starboard space bilge pump prior to taking passengers.
46 CFR 182.500
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 April 2023
Resolution: New bilge switch installed.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 18 April 2023
Resolved
Each ship transporting more that six passengers for hire equipped with a radiotelephone station must carry a radio operator who: holds a marine radio operator permit or higher class license. Master did not have marine radio operator permit. Provide marine radio operator permit.
47 CFR 80.158 (e)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 April 2023
Resolution: MROP provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 April 2023
Resolved
In systems and applications where flexible hoses are permitted to be clamped: Double hose clamping is required where practicable. Missing double hose clamps on bilge hose at suction and discharge ends. Provide double hose clamps.
46 CFR 182.410 (d) (1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2023
Resolved 19 April 2023
Resolution: Double hose clamps provided.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 12 October 2022
Resolved
A periodic examination made in accordance with the requirements of this subpart shall include the underwater hull and appendages, propellers, shafting, stern bearings, rudders, through hull fittings, sea valves and strainers, and shall be of sufficient scope to determine that these items are in satisfactory condition for the service intended. Both rudder stocks were pitted beyond acceptable limit for continual use.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 December 2022
Resolved 14 February 2023
Resolution: New custom rudder assembly ordered but due to supply, the rudder will not be ready until 30 December 2022. Vsl owner provided order invoice for the rudders.
14 Feb 2023 - New rudders installed. Sea Trial conducted. All sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 6 June 2022
Resolved
A vessel must comply with the structural design requirements of one of the standards listed. The port forward viewing port is fractured on the upper forward corner. Submit a repair proposal to be reviewed and approved by the attending USCG Marine Inspector. 46CFR177.300(c)
Complete at next drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2023
Resolved 15 November 2022
Resolution: Rectified during drydock. Also verified watertight integrity of all viewing ports while underway during seatrial on 15NOV22.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 June 2022
Resolved
A portable hand bilge pump must be capable of pumping water, but not necessarily simultaneously, from all watertight compartments. The manual bilge pump has a tear in rubber bellows that is causing the pump to leak. Replace or repair the manual bilge pump the satisfaction of the attending USCG Marine Inspector. 46CFR182.520(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2022
Resolved 17 June 2022
Resolution: New portable bilge pump provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 June 2022
Resolved
Where a flexible fill pipe section is necessary, suitable flexible tubing or hose having high resistance to salt water, petroleum oils, heat and vibration, may be used. When the flexible section is a nonconductor of electricity, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of a static charge when filling with fuel. The port and starboard fuel fill hoses are not properly bonded. Bond both hoses. 46CFR182.445(g)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2022
Resolved 17 June 2022
Resolution: Conductor provided to protect against generation of static charge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 June 2022
Resolved
A submersible electric bilge pump may be used as a power bilge pump only on a vessel of not more than 65 feet in length carrying not more than 49 passengers, other than a ferry, provided that the pump is listed by an independent laboratory as meeting the requirements in UL 1113. All four of the vessel’s electric bilge pumps are not UL rated. Replace installed bilge pumps with UL rated bilge pumps. 46CFR182.520(e)(1)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2022
Resolved 17 June 2022
Resolution: UL rated bilge pumps provided.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 6 June 2022
Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. The port and starboard rudder tiller linkage where the crossbar meets the yoke on both sides is worn beyond 25% of the stock material. Submit repair proposal to be reviewed and approved by the attending USCG Marine Inspector. 46CFR182.610(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2022
Resolved 17 June 2022
Resolution: Tiller crossbar rotated. New crossbar being fabricated.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 6 June 2022
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. The aft ventilation cover in the starboard engine compartment does not properly seal. Repair or replace the ventilation closure to the satisfaction of the attending USCG Marine Inspector. 46CFR182.465(h)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2022
Resolved 17 June 2022
Resolution: Vent closure device provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2022
Resolved
Connections must be made to battery terminals with permanent type connectors. The port and starboard house batteries have wing nuts on the conductors. Replace wing nuts with permanent type connectors. 46CFR183.350
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2022
Resolved 17 June 2022
Resolution: Permanent type connectors provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 June 2022
Resolved
The owner shall be prepared to conduct tests and have the vessel ready for inspection of the following: On a sailing vessel all spars, standing rigging, running rigging, blocks, fittings, and sails. Vessel does not have in place a preventative maintenance plan to adequately assess the safe condition of their sail rigging system in accordance with USCG NVIC 02-16. The vessel’s Preventative Maintenance Program requires the fore stay rolling furler to be removed annually to facilitate inspection of the fore stay. The rolling furler has not been removed in over a year. Remove rolling furler to facilitate inspection. 46CFR176.802 (a)(3)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2022
Resolved 17 June 2022
Resolution: Furler disassembled for inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 June 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2022
Resolved 11 June 2022
Resolution: Valid adult EAD pads provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 June 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2022
Resolved 5 August 2022
Resolution: Work Instruction 31 procedures provided.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 1 April 2021
Resolved
Both life floats showing damage beyond repair. Replace with life float that is approved under approval series 160.027 and with aggregate capacity that will accommodate at least 50% of the total number of persons permitted aboard. 46 CFR 180.205
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2021
Resolved 12 July 2021
Resolution: New life floats provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 April 2021
Resolved
Bilge high water alarm sounds at space other than operating station. Provide visual and audible high water alarm at the operating station for engine room and any space with through hull valve below the deepest load waterline. 46 CFR 182.530
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2021
Resolved 7 May 2021
Resolution: All bilge high water alarms provided a visual and audible alarm at the operating station.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 1 April 2021
Resolved
Forward hatches in accommodation space are not labeled as emergency escape. Provide labeling on both the inside and outside of each hatch in accommodation space with the words Emergency Exit, Keep Clear in 2 inch letters. 46 CFR 185.606
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2021
Resolved 1 June 2021
Resolution: Marking provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 April 2021
Resolved
Sail Rigging Preventative Maintenance Plan (PMP) not updated with all current configurations. In PMP provide sail plan, full rigging inventory, and inspection regime. Ensure all to log all inspections in accordance with vessel PMP. Keep copy of PMP on board vessel at all times and submitted revised version of PMP to [name withheld]. 46 CFR 176.840
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2021
Resolved 1 June 2021
Resolution: PMP provided with satisfactory updates.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 June 2020
Resolved
Vessel must comply with installation certificates required by the FCC in accordance with 46 CFR 184.502. Radio Safety Certificate was expired.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2020
Resolved 7 July 2020
Resolution: Valid Radio Safety Certificate provided.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 12 July 2019
Resolved
Life float weak links were oversized. Provide correct weak links in accordance with 46 CFR 176.808.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2019
Resolved 27 September 2019
Resolution: Correct weak links provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 July 2019
Resolved
Emergency fuel valves did not close completely. Prove correct operation in accordance with 46 CFR 176.804.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2019
Resolved 27 September 2019
Resolution: Fuel valves close completely.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 July 2019
Resolved
Rigging Preventative Maintenance Plan was unsatisfactory. Provide Preventative Maintenance Plan required by 46 CFR 176.840.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2019
Resolved 27 September 2019
Resolution: Satisfactory Preventative Maintenance Plan provided.
Operations/Management › Vessel Activity › Underway
Issued 31 October 2017
Resolved
Vessel needs to complete satisfactory sea trials under sail propulsion witnessed by an attending USCG Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2017
Resolved 3 November 2017
Resolution: Vessel conducted satisfactory sea trials under sail propulsion with an attending USCG Marine Inspector.
Operations/Management › Drills/Instruction › Not Conducted
Issued 31 May 2016
Resolved
Vessel is not conducting crew drills and training IAW 185.420. Discussed importance and suggested other ways to keep track of training.
Due 30 June 2016
Resolved 31 May 2016
Resolution: Vessel has implemented monthly training in order to ensure complaince with regs.