MAURY USCG vessel records
← All vessels

JUNIOR G

Built
1975
Last inspected
29 March 2025
Documentation
Case Pending · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 29 March 2025
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 11 calendar years (1994–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH7979
132615
Flag
UNITED STATES
Maury page id
psix-132615

Documentation record

Registered dimensions (L × B × D)40.5 ft × 18.0 ft × 6.8 ft
Registered tonnagegross 47 / net 32
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSNEED SHIPBUILDING CO · ORANGE, TX, UNITED STATES · built 1975
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un
DocumentationCase Pending · issued 30 June 2004
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it32 - Regulatory (Subpart C or D), Net Ton
47 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 18 inspections, each with its date, unit and type; 28 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 5 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 5

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

LISA ANN Industrial Vessel · MISLE 1860689 · 29 March 2025 · activity 8111911BOBBIE G Towing Vessel · MISLE 329521 · 12 April 2021 · activity 7183591CBR 812 Freight Barge · MISLE 1115396 · 12 April 2021 · activity 7183591CBR 815 Freight Barge · MISLE 1144353 · 12 April 2021 · activity 7183591TRINITY Freight Barge · MISLE 41496 · 13 September 1994 · activity 40442

Inspection history · 18

29 March 2025 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8101733
29 March 2025 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8111911
17 March 2025 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8087200
5 March 2024 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7850397
14 February 2023 Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7636832
17 January 2023 Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7622660
5 October 2022 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7572451
26 May 2022 Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7459517
28 April 2021 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7186983
12 April 2021 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7173829
12 April 2021 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7183591
3 September 2020 Initial Certification · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7049217
11 August 2020 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7030138
8 December 2019 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6870883
6 February 2017 Industry Initiated Exam · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6080810
26 July 2012 Industry Initiated Exam · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4391380
3 May 1999 Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1511087
13 September 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 40442

Deficiency record · 28

10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 29 March 2025 Resolved
The officer in charge of a navigational watch must conduct a navigation assessment for the intended route and operations prior to getting underway. The navigation assessment must incorporate the requirements of pilothouse resource management of § 140.640, assess operational risks, and anticipate and manage workload demands. At a minimum, this assessment must consider: Air draft relative to bridges and overhead obstructions taking tide and river stage into consideration;
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 29 March 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 March 2025 Resolved
A towing vessel that is: (1) Certificated for rivers... must be equipped with either: (i) An approved 160-B semi-portable fire-extinguishing system to protect the engine room or (ii) A fixed fire-extinguishing system installed to protect the engine room. MI Found 160-B semi-portable extinguisher under-pressurized.
Action required: 60 - Rectify deficiencies prior to movement
Due 17 March 2025
Resolved 18 March 2025
Resolution: Received report and pictures on new installed 160-B-C portable fire extiguisher.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 March 2025 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. MI identified electrical ground in 110 volt AC system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2025
Resolved 18 March 2025
Resolution: Received report on new 110v outlet installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 January 2023 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Turbo drain line has excess oil online.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 20 January 2023
Resolved 18 January 2023
Resolution: Cleaned and tightened fittings for turbo drain line on main engine.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 January 2023 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Generator windings excess oil.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2023
Resolved 18 January 2023
Resolution: Generator windings have been cleaned. all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 January 2023 Resolved
arriage requirement. A towing vessel must carry a combination of day and night visual distress signals indicated in Table 141.370 of § 141.370 for specified areas where the vessel operates. Missing 01 orange flare.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 20 January 2023
Resolved 18 January 2023
Resolution: Orange distress flare has been replaced.
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 18 January 2023 Resolved
Towing vessels must be equipped with the following equipment, as applicable to the area of operation: (A) Fathometer (except Western Rivers). Fathometer not installed.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2023
Resolved 14 February 2023
Resolution: Fathometer installed and operating properly.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 18 January 2023 Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route. Gaskets need to be replaced
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2023
Resolved 14 February 2023
Resolution: Port lights were sealed and shut, SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 May 2022 Resolved
Owner or managing operator must implement procedures to identify and mitigate health and safety hazards to include electrical. Battery for tender davit was unsecured on deck creating a possible unsafe condition.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2022
Resolved 18 January 2023
Resolution: battery was secured and in a battery box. all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 April 2021 Resolved
Vessel shall provide closure devices to ensure watertight integrity for spaces which open to exterior of vessel. Replace gasket on hatches with watertight gasket leading to engine room and galley.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2021
Resolved 13 April 2021
Resolution: Vessel replaced gasket on engine room door.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 April 2021 Resolved
Installed electrical power source(s) must be capable of carrying the elctrical load of the towing vessel under normal operating conditions. Vessel's main power source failed. Vessel shall proceed via assist vsl to Gulf Island Dock in Houma, LA for appropriate repairs to the satisfaction of the OCMI. 46 CFR 143.400(b)
Action required: 17 - Rectify deficiencies prior to departure
Due 12 April 2021
Resolved 13 April 2021
Resolution: Verified ship power with generator taking the load. Verified new voltage regulator.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 March 2021 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who occupy a position, or perform the duties and functions of a position, required by the vessel’s Certificate of Inspection. Vessel rep stated a third-party oversees the random testing of crewmembers. Provide documentation to the satisfaction of the attending USCG Marine Inspector verifying the third-party is responsible for establishing and overseeing the random chemical testing.
Action required: 705 - Other - as specified
Resolved 26 March 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 March 2021 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who occupy a position, or perform the duties and functions of a position, required by the vessel’s Certificate of Inspection. Vessel rep stated a third-party oversees the random testing of crewmembers. Provide documentation to the satisfaction of the attending USCG Marine Inspector verifying the third-party is responsible for establishing and overseeing the random chemical testing.
Action required: 705 - Other - as specified
Resolved 26 March 2021
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 8 March 2021 Resolved
Steering systems shall operate smoothly. Upon testing of the steering system, the steering appeared to exhibit a significant amount of vibration. Vessel rep is required to provide verification the vibration is considered normal to the satisfaction of the USCG Marine Inspector.
Action required: 705 - Other - as specified
Resolved 26 March 2021
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 8 March 2021 Resolved
A towing vessel must carry adequate and up-to-date charts, maps, and nautical publications for the intended voyage, including: “U.S. Coast Pilot” or similar publication. Vessel did not have the U.S. Coast Pilot or similar publication. Provide appropriate publication to the satisfaction of the USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 March 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 March 2021 Resolved
Portable fire extinguishers were not installed in approved brackets. All portable fire extinguishers must be secured in an approved bracket or suitably secured to prevent chaffing/dismounting to the satisfaction of the attending USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 March 2021
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 8 March 2021 Resolved
Each towing vessel must be equipped with at least one fire axe that is readily accessible for use from the exterior of the vessel. The fire axe was not readily accessible from the rear of the vessel, it was blocked by towing equipment. Provide a suitable location at the rear of the vessel for the fire axe so that is readily accessible to the satisfaction of the USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 March 2021
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 March 2021 Resolved
Fixed fire-extinguishing systems required by this part must be approved by the Commandant (CG-ENG). Existing equipment and installations, of a type not required, or in excess of that required by this part, not meeting the applicable requirements of this part may be continued in service so long as they are in good condition and accepted by the local OCMI or TPO. The hose on the fire pump piping is warped and distorted. Repair to the satisfaction of the USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 March 2021 Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. The battery in the engine room had spring clamps. Replace with suitable connections to the satisfaction of the USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 March 2021
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 8 March 2021 Resolved
Electrical equipment and electrical cables must be suitably protected from wet and corrosive environments. The shower in the berthing area has an exposed electrical outlet attached to the overhead light. Remove or replace with a satisfactory watertight connection to the satisfaction of the USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 March 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 March 2021 Resolved
Electrical equipment and electrical cables must be suitably protected from wet and corrosive environments. All exterior wiring IVO the bridge needs to be protected from environmental conditions to the satisfaction of the USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 March 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 March 2021 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel has lighting and other appliances plugged into electrical splitter in engine room. Electrical splitter needs to be removed and proper electrical source needs to be provided to the satisfaction of the attending USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 March 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 September 2020 Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the 50% of the vessels that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date the action for this deficiency shall be changed to a 60(Rectify deficiencies prior to movement) and they vessel may no longer be permitted to operate.
Action required: 705 - Other - as specified
Due 3 December 2020
Resolved 26 March 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 August 2020 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protection against hazards to life, property, and the environment. Vessel owner stated vessel is on a Lakes, Bays, Sounds route. Vessel does not have life saving equipment, navigation equipment for the route and Marine inspectors did not complete an exam to verify key items not listed above due to no crew on board. Vessel is required to have a Coast Guard inspection prior to movement to verify major systems on the vessel and crew knowledge meets the regulations and route intended.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 March 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 August 2020 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. During inspection, observed loose and exposed wire throughout engine room. Make permanent repairs to electrical wiring to the satisfaction of the attending USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2020
Resolved 3 September 2020
Resolution: Loose and exposed wire properly installed in junction box or conduit.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 August 2020 Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. The valve must be installed in the fuel piping directly outside of the fuel oil supply tank. The valve must be operable from a safe place outside the space where the valve is installed. Each remote valve control must be marked in clearly legible letters, at least 25 millimeters (1 inch) high, indicating the purpose of the valve and the way to operate it. During inspection, vessel was not outfitted with a remote fuel shutoff valve at the fuel oil supply tank. Prior to movement, make remote fuel shutoff valve operational directly outside the tank to the satisfaction of the attending USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2020
Resolved 3 September 2020
Resolution: Fuel shutoff valves installed and operate as desingned.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 August 2020 Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks that provide strength and support equivalent to fixed rails. Make rails or equivalent protection on main deck to the satisfaction of the attending USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2020
Resolved 3 September 2020
Resolution: Hand rails installed on main deck superstructure.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 August 2020 Resolved
Smoke detection in berthing spaces. Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces. This may be accomplished by an installed detection system, or by using individual battery-operated detectors meeting UL 217 (incorporated by reference, see §136.112 of this subchapter). Detection systems or individual detectors must be kept operational at all times when the crew is onboard the towing vessel. During inspection, smoke detector was inoperable. Make permanent repairs to smoke detector and test to the satisfaction of the attending USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2020
Resolved 3 September 2020
Resolution: New smoke detector installed in berthing area.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.