Records from 2016 to 2026. Most recent: inspection, 13 May 2026.
Inspection history · 15
13 May 2026
ISPS Exam · COC-MODU Annual
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8373070
4 May 2026
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8361489
18 September 2025
COC-MODU Renew
Type not classified · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8237382
15 April 2025
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8112066
14 January 2025
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8081593
29 May 2020
ISPS Exam · COC-MODU Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6889462
14 June 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6732135
25 January 2019
COC-MODU Renew
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6618505
23 April 2018
COC-MODU Annual
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6403867
11 April 2017
Type not recorded
No type recorded · Suspension & Revocation National Center of Expertise · Activity 6122196
4 February 2017
In-Service Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 6082773
22 December 2016
COC-MODU Renew
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6067865
17 December 2016
In-Service Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 6059283
6 June 2016
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5898947
10 May 2016
COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5869662
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 18 September 2025
Resolved
For each breathing apparatus a fireproof lifeline of at least 30M in length shall be provided. The lifeline shall successfully pass an approval test by statical load of 3.5kN for 5 min without failure. The lifeline shall be capable of being attached by means of snap-hook to the harness of the apparatus or to a separate belt in order to prevent the breathing apparatus becoming detached when the lifeline is operated. MI observed multiple lifeline snap-hooks missing or not able to be operated as per design standards(corrosion. Replace or repair all required lifelines to the above required standard and submit to class for satisfactory approval. Upon class approval submit proper documentation to MI for correction.
16AC
MODUCODE(09)9.13.1
FSSCODE(15)2.1.3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2025
Resolved 1 October 2025
Resolution: Recieved appropriate documentation via ABS and vessel showing items were ordered. ABS has open deficency and will track closure and status.
Lifesaving › Lifeboat › Propulsion Engine
Issued 10 May 2016
Resolved
V-belts on engine are loose and need adjusted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 6 June 2016
Resolution: Corrected and cleared.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 10 May 2016
Resolved
Life Bouy has hole in it and needs replaced.
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 6 June 2016
Resolution: Corrected and cleared.