Records from 2014 to 2025. Most recent: inspection, 10 June 2025.
Inspection history · 24
10 June 2025
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8156613
7 June 2025
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8157906
18 March 2025
COC-MODU Renew · Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8104442
26 October 2024
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8028329
10 July 2024
COC-MODU Renew · ISPS Exam
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7958660
4 January 2024
COC-MODU Renew · Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7845257
9 October 2023
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7807594
22 April 2022
COC-MODU Renew
Type not classified · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7443204
5 July 2021
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7302123
6 May 2021
COC-MODU Annual
Type not classified · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7190491
28 April 2020
ISPS Exam · COC-MODU Renew · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6942240
18 July 2019
ISPS III Exam · COC-MODU Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6767769
4 April 2019
ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6643149
15 March 2019
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6643221
14 May 2018
COC-MODU Renew
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6625410
23 January 2018
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6351258
19 September 2017
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6271501
24 May 2017
Deficiency Check · COC-MODU Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6156157
11 April 2017
Type not recorded
No type recorded · Suspension & Revocation National Center of Expertise · Activity 6122196
4 January 2017
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6065919
16 May 2016
COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5882192
4 August 2014
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4991367
16 May 2014
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4860332
13 May 2014
Administrative Inspection · COC-MODU Renew
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4824991
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 24 May 2017
Resolved
lifeboats shall be launched and manovoured in the water by it's assigned operating crew, at least once every three months. Lifeboats have not bee launched in 8 months. 09 MODU / 14.13.6
Action required: 705 - Other - as specified
Due 24 June 2017
Resolved 17 June 2017
Resolution: Master provided evidance of L/B launching.
Documentation › Certificates/Documents › MODU Safety Certificate
Issued 24 May 2017
Resolved
MODU Safety certificate does not list exemptions for carriage of L/B food and immursion suites. 09 MODU / 1.4
Action required: 705 - Other - as specified
Due 24 June 2017
Resolved 12 June 2017
Resolution: Item was cleared from class clarification of regulation.
Documentation › Certificates/Documents › International Air Pollution Prevention Certificate
Issued 24 May 2017
Resolved
The survey of Marine Diesel engines and equipment for compliance with regulation 13 of this anned shall be in accordance with the revised Nox Technical code 2008. Changes were not recorded in the record book of engine parameters. MARPOL Annex VI reg 13 / NOx Tech code Reg 6.2.2.8
Action required: 705 - Other - as specified
Due 24 June 2017
Resolved 11 June 2017
Resolution: Item was cleared from evidence of creation of proper tech files.
Engineering › Bilge Water Management System › Valve
Issued 17 May 2014
Resolved
) Installed emergency bilge suction valves in multiple pump rooms were found to be in an inoperable condition. Conduct maintenance on all emergency bilge valves and prove proper operation of the same. Put preventive maintenance procedures in place to ensure that these valves are maintained in an operable condition at all times. Cite 88 SOLAS 1/11(a). Action 40a,b,c.
Due 24 May 2014
Resolved 22 May 2014
Resolution: Documentation provided showing satisfactory completion.
Navigation › Voyage Data Recorder › Voyage Data Recorder (VDR)
Issued 17 May 2014
Resolved
VDR is inoperable w/the most recent Dispensation Letter from Flag State requiring operation prior to 25May2014. Noted that parts were received onboard & awaiting technician to affect repairs. Provide copy of the servicing technician's report showing full operating capability of VDR prior to the due date imposed by Flag State. Cite 04 SOLAS V/20.1.4. Action 50a,b,c. Extended to 08Jul on 20Jun.
Due 8 July 2014
Resolved 11 July 2014
Resolution: Documentation provided showing satisfactory completion. VDR is operational after numerous issues with the VDR system were corrected.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 17 May 2014
Resolved
Numerous fire doors were found not to be fully closing throughout the vessel. Conduct a survey of all fire doors and affect repairs to those that are not fully closing. Provide documentation showing that all fire doors are properly operating. Cite 09 MODU 9.2.9. Action 50a,b,c.
Due 17 June 2014
Resolved 11 June 2014
Resolution: Documentation provided showing satisfactory completion.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 17 May 2014
Resolved
The forward Laundry Room door was found to be latched open several times during the course of the inspection due mainly to a ventilation imbalance that requires excessive force to get the door open from a closed position. Correct the ventilation imbalance and install a latch of the fail-safe design if the door is to be maintained in an open position. Cite 09 MODU 9.2.10. Action 50a,b,c.
Due 17 June 2014
Resolved 27 May 2014
Resolution: Documentation provided showing satisfactory completion.
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 17 May 2014
Resolved
The regulator pressure gauge on Lifeboat 6 was found to be damaged/inoperable. Noted that replacement is on order and awaiting arrival onboard. Replace gauge and ensure that gauge measurement units and posted instructions match. Cite LSA IV/4.8. Action 16a,b,c.
Due 31 May 2014
Resolved 17 May 2014
Resolution: Documentation provided showing satisfactory completion. Note that the replacement was completed prior to issuance of the typed Deficiency Report.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 17 May 2014
Resolved
Two of four Galley roll-down shutters failed to operate properly and fully close during testing by the crew. Consult with manufacturer or fire equipment servicing company to affect repairs and prove proper operation/automatic closure of all four Galley shutters with removal of the thermal links (to simulate release during a fire). Cite 09 MODU 9.2.10. Action 16a,b,c.
Action required: 705 - Other - as specified
Due 1 March 2015
Resolved 14 May 2018
Resolution: Galley doors were operational during 2018 COC Renewal exam.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 17 May 2014
Resolved
Openings in rated fire boundaries are to retain integrity of boundary in case of fire. Observed numerous trays/pans below roll-down fire shutter for Scullery. These items would prevent full closure of shutter in case of thermal release & boundary integrity would be compromised. Ensure areas in the path of the Galley/Scullery roll-down fire shutters remain clear. Cite 09 MODU 9.2.10. Action 10c.
Action required: 705 - Other - as specified
Resolved 17 May 2014
Resolution: Cleared while still onboard. Documented on written Deficiency Report issued on 17May14.
Fire Fighting › Means of Escape › Handrails/Handholds
Issued 17 May 2014
Resolved
The ROV Control Van has an elevated escape hatch without proper means to safely egress/transit through the hatch. Provide/install interior and exterior means to safely access and pass through the elevated escape hatch (steps/grab rail). Cite 09 MODU 9.4.1.3. Action 50a,b,c.
Due 17 June 2014
Resolved 15 June 2014
Resolution: Documentation provided showing satisfactory completion.
Operations/Management › Navigation Safety › Proper Use of Day Shapes
Issued 17 May 2014
Resolved
The windsock should be located in an area that provides accurate/undisturbed airflow and be visible to a helicopter in flight. Relocate the windsock to comply with these requirements. Cite 09 MODU 13.5.1. Action 16a,b,c.
Due 31 May 2014
Resolved 26 May 2014
Resolution: Documentation provided showing satisfactory completion.
Fire Fighting › Means of Escape › Doorways
Issued 17 May 2014
Resolved
Fire doors leading into the aft Thruster Rooms (from the Converter Rooms) were found to have locks installed that could block the only egress path from the Thruster Rooms if inadvertently locked. Disable or revise locking arrangement to not impede egress paths from all Thruster Rooms. Cite 09 MODU 9.4.1.3. Action 16a,b,c.
Due 31 May 2014
Resolved 29 May 2014
Resolution: Documentation provided showing satisfactory completion.
Fire Fighting › Means of Escape › Blocked
Issued 17 May 2014
Resolved
The escape trunk on the Main Deck at the Stbd Engine Room entrance was found to be used as a storage area with empty 55-gal drums blocking the egress path from the ladder to the door. Clear pathway and ensure that escape routes are maintained in an unobstructed condition at all times. Cite 09 MODU 9.4.1.3. Action 40a,b,c.
Due 24 May 2014
Resolved 21 May 2014
Resolution: Documentation provided showing satisfactory completion.
Stability › Watertight Integrity › General
Issued 17 May 2014
Resolved
The manual pump handles were missing for the sliding Water Tight Doors (WTD's) for Engine Room 3 leading into Engine Rooms 1 & 2. Provide missing handles and ensure that they are stored in the adjacent storage receptacle and ready for emergency use at all times. Cite 09 MODU 3.6.5.1 & 3, 06 SOLAS II-1/13-1.2. Action 40a,b,c.
Due 24 May 2014
Resolved 21 May 2014
Resolution: Documentation provided showing satisfactory completion.
Engineering › Thrusters › Bearing
Issued 17 May 2014
Resolved
Thruster 4 replacement was in process while onboard. Provide manufacturer's technician and ABS reports showing acceptance and testing. Reports should prove that Thruster 4 is at full capability in all aspects and that the vessel's full DP capabilities are restored prior to the first drilling activities/latch-up. Cite 09 MODU 4.13. Action 66a,b,c.
Action required: 705 - Other - as specified
Resolved 6 June 2014
Resolution: Documentation provided showing satisfactory completion.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 17 May 2014
Resolved
Aft cranes had a previous mid-air collision. #2 Crane (85T) had minimal damage, was inspected by the manufacturer & rtn'd to service. #4 Crane (165T Heave Compensated) suffered more extensive damage & is currently undergoing insp & NDE work. Provide manufacturer (NOV) & ABS reports w/findings, repairs, testing & acceptance back into service for Cranes #2 & #4. Cite 09 MODU 12.1.6. Action 50a,b,c.
Due 17 June 2014
Resolved 6 June 2014
Resolution: Noted that research was in process to provide warning/prevent collision with other dynamic objects while we were onboard. Documentation provided showing satisfactory completion w/both cranes repaired as needed, accepted & back in service.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 17 May 2014
Resolved
Sliding WTD's observed in open position during exam. WTD's posted w/paper placards noting normal position. MOM did not give specific instructions for door positions. WTD's (also serve as Fire Doors) to be maintained in closed position at all times to retain integrity of DP3 system related to fire/flooding protection. Cite 09 MODU 4.13, MSC/Circ.645 3.2.4, DP FMEA 10.1.1.1 & 10.3.2.3 & 10.3.3.3.
Action required: 705 - Other - as specified
Resolved 22 May 2014
Resolution: Documentation provided showing satisfactory completion. All sliding WTD''s maintained in a closed position except when crewmwmbers are passing through.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 17 May 2014
Resolved
Laundry Chute doors found to be missing door rating/approval label (most had labels & listed as A-0). All also found to be non-self-closing w/bottom door left in open position at all times. Laundry Chute is an enclosure to the elevator trunk that penetrates multiple decks. Provide self-closing doors equiv to the blkhd rating for Chute at all deck levels. Cite 09 MODU 9.2.9 & 9.3.5. Action 50a,b,c.
Due 14 July 2014
Resolved 10 July 2014
Resolution: Documentation provided showing satisfactory completion. Initially rebuttled but further review by ABS found it to be a legitimate concern. Bottom door was fitted w/std external door closer. All deck levels were fitted w/spring/self-closing hinges.