Records from 2016 to 2026. Most recent: inspection, 15 June 2026.
Documentation record
Registered dimensions (L × B × D)34.3 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 14 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS INC · CAPE MAY COURT HOUSE, NJ, UNITED STATES · built 2015
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portHONOLULU, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 31
15 June 2026
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8432032
30 January 2026
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8304238
22 June 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8163940
21 June 2025
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8192258
25 April 2025
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8120274
16 January 2025
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8050488
2 February 2024
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7839642
28 April 2023
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7634586
9 November 2022
COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7560009
4 February 2022
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7392315
1 August 2021
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7278312
9 April 2021
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7171983
12 February 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7140300
6 November 2020
Examination of Repairs · Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7091084
5 November 2020
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7091016
23 January 2020
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6895864
2 January 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6882431
28 July 2019
Type not recorded
No type recorded · Station Honolulu · USCG Oceania District (CGD-O) · Activity 6765443
28 July 2019
Type not recorded
No type recorded · Station Honolulu · USCG Oceania District (CGD-O) · Activity 6765546
25 April 2019
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6669856
24 January 2019
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6584606
21 February 2018
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6375672
15 November 2017
Drydock Exam · DAPI Audit · Deficiency Check · Administrative Inspection · Internal Structural Exam · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6307028
27 October 2017
Drydock Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6296551
17 April 2017
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6132609
7 December 2016
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6055005
23 November 2016
DAPI Audit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6062925
7 October 2016
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6027477
8 March 2016
In-Service Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5831077
7 March 2016
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5861569
27 January 2016
Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 5805712
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 June 2025
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel lost propulsion on 21JUN2025. Vessel is restricted from carrying passengers for hire until proper operation of propulsion system is demonstrated to attending marine inspector.
46 CFR 182.200(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2025
Resolution: Inspected new alternator and conducted sea trial. Inspection SAT.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 November 2022
Resolved
Each vessel must be equipment with at least two operable portable battery lights. Vessel did not have two portable battery lights. Provide two portable battery lights.
46 CFR 183.430
Action required: 10 - Deficiency Rectified
Resolved 9 November 2022
Resolution: Vessel rep bought two flashlights prior to completion of inspection.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 February 2022
Resolved
On a vessel of at least 7.9 meters in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: The forward bilge alarm visual indicator is not working at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2022
Resolved 14 February 2022
Resolution: Repaired connections.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 February 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate up-to-date: Chart or large enough to scale to make safe navigation possible. Captain does not have up-to-date charts on the vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2022
Resolved 14 February 2022
Resolution: Purchased new charts.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 12 February 2021
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: For fixed-gas extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Provide proof of annual servicing for extinguisher in battery compartment.
46CFR176.810(b)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2021
Resolution: Extra fireboy was inspected. Recieved photographic evidence, uploaded to activity.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 12 February 2021
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Replace damaged transmission line and intake pipe.
46CFR182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2021
Resolution: Installed new water intake hose and trans hose. Received photographic evidence, uploaded to activity.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 November 2020
Resolved
Propulsion machinery must be capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel experienced an unknown electrical failure which caused the vessel to lose propulsion. Conduct damage assessment, complete proper repairs, and prove proper operation of vessel underway prior to departure.
46 CFR 182.200
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 November 2020
Resolution: Verified proper installation of new alternator and power toggle switch. Conducted successful sea trials.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 16 November 2017
Resolved
Repair audible alarm for pre-engineered fire supression system IAW 46 CFR 181.420(b)(1).
Action required: 705 - Other - as specified
Due 16 December 2017
Resolved 14 December 2017
Resolution: Verified audible alarm is operational
Construction/Loadline › Hull › Side Shell
Issued 7 November 2017
Resolved
Repair minor chips to gel coat on port and starboard side shell
Action required: 705 - Other - as specified
Resolved 9 November 2017
Resolution: Vessel sanded and repaired/repainted.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 7 October 2016
Resolved
Resolve outstanding electrical deficiencies issued in 2015.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 27 October 2017
Resolution: Vessel's battery switch now controls all electrical equipment. Bilge pumps are no longer bypassed.
Engineering › Bilge Water Management System › Pump
Issued 7 October 2016
Resolved
Provide working visual indicators at operating station for both power submersible bilge pumps.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 7 December 2016
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 7 October 2016
Resolved
Update emergency instructions to include steps for securing ventilation openings & fuel for fire response as applicable.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 7 December 2016
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 7 October 2016
Resolved
Schedule DAPI Audit for company drug and alcohol testing program.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 5 December 2016
Resolution: Sector INV will no longer conduct DAPI audits.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 7 October 2016
Resolved
Provide covers for ventilation openings in engine room that actually close off the openings.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 7 December 2016
Navigation › Piloting/Steering › Marine Charts
Issued 7 October 2016
Resolved
Provide updated charts & navigation publications
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 7 December 2016
Accommodation/Occupational Safety › Ventilation › General
Issued 7 October 2016
Resolved
Submit special consideration request to deviate from the ventilation requirements of 46CFR 182.465.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 5 December 2016
Resolution: Special consideration submittal was reviewed and the vessel's current ventilation configuration was deemed in compliance with regulations (46 CFR 182.465).
Fire Fighting › Fixed Fire Detection System › Approval
Issued 7 October 2016
Resolved
Replace installed fire detection system with one that is USCG type approved, or request and receive OCMI special consideration to keep the non-USCG approved system.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 7 November 2017
Resolution: Vessel has both the preexisting fire detection as well as an approved fire detection system installed.