Records from 2016 to 2026. Most recent: inspection, 24 June 2026.
Inspection history · 19
24 June 2026
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8413739
20 May 2025
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8140480
27 February 2025
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8085618
29 January 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8080749
14 August 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7981040
9 August 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7764094
10 August 2022
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7530815
18 August 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7307675
27 February 2020
COI Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6916693
21 January 2020
Administrative Inspection · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6891495
24 July 2019
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6755059
11 July 2018
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6475253
4 July 2018
Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6473235
13 April 2018
Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6391471
8 April 2018
Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6390001
31 July 2017
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6226658
20 June 2016
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5913193
20 June 2016
Examination of Repairs · Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5934241
8 June 2016
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5901835
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 August 2021
Resolved
The lights prescribed by these Rules shall be exhibited from sunrise to sunset in restricted visibility and may be exhibited in all other circumstances when it is deemed necessary. Vessel all-around light was obstructed 180 degrees by the gunnel on the upper deck.
33 CFR 83.20(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2021
Resolved 8 September 2021
Resolution: Received satisfactory photo from vessel rep confirming unobstructed all-around light installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 August 2021
Resolved
Cable and wire for power and lighting circuits must meet section 310.13 of NFPA 70, be listed by UL, as UL Boat or UL Marine cable or meet 111.60-11 in subchapter J of this chapter for wire. Vessel had drop lights plugged into every compartment space for permanent lighting.
46 CFR 183.340(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2021
Resolved 16 September 2021
Resolution: Received photo from vessel rep [name withheld] confirming unapproved droplights in engine space de-energized and properly installed/approved 12v lights and associated wiring operating properly.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 March 2020
Resolved
from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Vessel had daisy chained surge protectors in the bar area.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2020
Resolved 9 March 2020
Resolution: Verified the installation of adequate electrical outlets and the removal of daisy chains & surge protrctors – ALL SAT.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 3 March 2020
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: Operational test of the means provided for pumping bilges.
Bilge suction was not achieved in Compartment 6 underneath the operating station.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2020
Resolved 9 March 2020
Resolution: Verified proper operation of bilge suction in Compartment 6 which is located underneath the operating station – ALL SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 3 March 2020
Resolved
At each inspection for certification and at every other vessel inspection all observed hazardous situations must be corrected. Main entry door for passengers and crew had compromised hinges and was in danger of falling off.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2020
Resolved 9 March 2020
Resolution: Verified proper repairs made to the main entry door – ALL SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 March 2020
Resolved
On passenger decks of a ferry or of a vessel on an excursion trip the following must be installed: Bulwarks; Chain link fencing or wire mesh that has openings of not more than 4 inches in diameter; or Bars, slats, rail courses, or an equivalent spaced at intervals of not more than 4 inches. Plastic mesh was found installed and also contained an opening greater than 4" in diameter.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2020
Resolved 9 March 2020
Resolution: Verified proper metal wire cable that was rated for 300+ pounds spaced at intervals of not more than 4 inches.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 3 March 2020
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 1 inch numbers and letters at the entranceway to that deck. Capacity limit was observed on the top deck port and starboard side vice the entry way on each ladder well leading to the deck. Lettering was also deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2020
Resolved 9 March 2020
Resolution: Verified the capacity rating for the upper deck was properly stenciled at the entranceway to that deck – ALL SAT.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 March 2020
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1" high indicating purpose and
direction of operation. Letters no longer legible.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2020
Resolved 9 March 2020
Resolution: Verified proper lettering of the remote fuel shut-off’s – ALL SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 3 March 2020
Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Vessel name faded/worn off and was no longer legible.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2020
Resolved 9 March 2020
Resolution: Verified proper labeling of ring buoy – ALL SAT.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 3 March 2020
Resolved
The master or person in charge of a ship shall ensure that one or more (garbage) placards meeting the requirements of this section are displayed in prominent locations and in sufficient numbers so that they can be read by the crew and passengers. Garbage placard(s) not posted.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2020
Resolved 9 March 2020
Resolution: Verified that a new Garbage placard was posted.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 3 March 2020
Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 0.5 inches high: “DISTRESS SIGNALS”. Flares were not stored in a container meeting the above requirements.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2020
Resolved 9 March 2020
Resolution: Verified that flares were being properly stored in a portable watertight container that was labeled “DISTRESS SIGNALS” – ALL SAT.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 3 March 2020
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2020
Resolved 9 March 2020
Resolution: Verified new batteries and proper operation of vessel’s bull horn – ALL SAT.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 3 March 2020
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date publications listed in 46CFR184.420. Vessel's Coast Pilot and Light List excerpts were out of date.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2020
Resolved 9 March 2020
Resolution: Verified that vessel had up-to-date Coast Pilot and Light List publications onboard – ALL SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 3 March 2020
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Vessel's starboard engine did not have a rotating machinery cover or guard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2020
Resolved 9 March 2020
Resolution: Verified that the vessel's starboard engine was outfitted with a safety guard in order to protect personnel from rotating parts – ALL SAT.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 3 March 2020
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. The emergency instructions must be designed to address the particular equipment, arrangement, and operation of each individual vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2020
Resolved 9 March 2020
Resolution: Verified that shipboard emergency instructions were designed to address the particular equipment, arrangement, and operation of the actual vessel (“ship-specific”) – ALL SAT.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 3 March 2020
Resolved
The owner operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by §185.510.
Vessel lacked documentation of required drills to include abandon ship described in 46CFR185.520.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2020
Resolved 9 March 2020
Resolution: Verified the presence of documented drills and training for MOB, Shipboard Fire and Abandon ship scenarios – ALL SAT.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 July 2018
Resolved
Replace extinguished stern light.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2018
Resolved 12 July 2018
Resolution: Witnessed operational light
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 July 2018
Resolved
Replace inoperable bilge float switch in Pilot house compartment.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2018
Resolved 12 July 2018
Resolution: Witnessed properly operating bilge float switch.
Construction/Loadline › Structures › Superstructure
Issued 20 June 2016
Resolved
Provide written plan for repairs, should include how work will be conducted and materials to be used.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2016
Resolved 20 June 2016
Resolution: Plan received.
Construction/Loadline › Structures › Superstructure
Issued 20 June 2016
Resolved
Repairs shall be conducted to the satisfaction of attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 8 July 2016
Resolution: Recieved email pictures of repair process.