This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
145 - Regulatory (Subpart C or D), Gross Ton
99 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-133681
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. Only barges and towing
vessels are in this archive, so any other vessel type in the same activity does not
appear here: these lists are a floor, not a complete manifest.
Remove in a manner as to not create environmental damage excessive oil within the vessel's bilges that creates increased risk of fire and pollution incident.
Condition: Unknown
Due 11 March 1998
Resolved 11 March 1998
Construction/Loadline
Issued 11 March 1998Resolved
Renew wasted bridge deck stabd side railing to sound condition.
Condition: Unknown
Due 11 March 1998
Resolved 11 March 1998
Electrical
Issued 11 March 1998Resolved
Demonstrate the operation of the towing navigation light following replacement of the unit's broken light bulbs. Discrepancy to be corrected prior to any towing operation being conducted, but not later than 01Apr98.
Condition: Unknown
Due 11 March 1998
Resolved 11 March 1998
Fire Fighting
Issued 11 March 1998Resolved
Renew wasted fire monitor control handle support bracket.
Condition: Unknown
Due 11 March 1998
Resolved 11 March 1998
Construction/Loadline
Issued 11 March 1998Resolved
Demonstrate the proper operation of all port hole covers following the removal of paint from the threads of the port hole cover bolt closures.
Condition: Unknown
Due 11 March 1998
Resolved 11 March 1998
Electrical
Issued 11 March 1998Resolved
Permanently wire radio power supply box on the bridge to eliminate potential risk of injury to personnel.
Condition: Unknown
Due 11 March 1998
Resolved 11 March 1998
Lifesaving
Issued 11 March 1998Resolved
Provide ring buoy on stbd side with retroreflective material, becketted grabline, and permanently mark with name of vessel.
Condition: Unknown
Due 11 March 1998
Resolved 11 March 1998
Electrical
Issued 11 March 1998Resolved
Modify battery box to prevent pinching/crimping of electric cables attachedto batteries within the box.
Condition: Unknown
Due 11 March 1998
Resolved 11 March 1998
Electrical
Issued 11 March 1998Resolved
Secure wet-cell battery within the battery box such that unanticipated, undesired movement of the battery will not occur.
Condition: Unknown
Due 11 March 1998
Resolved 11 March 1998
Engineering
Issued 11 March 1998Resolved
Conduct guaging of the aft wall of the fuel tank at most wasted areas. Written guaging results, which are to include a minimum of six points guaged, and original tank scantlings are to be provided to USCG Marine Safety Detachment Saipan not later than 01APR98.
Condition: Unknown
Due 11 March 1998
Resolved 11 March 1998
Construction/Loadline
Issued 11 March 1998Resolved
Aft stbd deck house is deteriorated and holed. Crop and renew deteriorated areas not later than 01APR98 using good marine practice.
Condition: Unknown
Due 11 March 1998
Resolved 11 March 1998
Electrical
Issued 11 March 1998Resolved
Install appropriate electrical junction box covers at all boxes which are missing covers, including but not limited to, the junction box in way of the internal ladder leading to the bridge and internal engineroom in way ofthe aft centerline door.
Condition: Unknown
Due 11 March 1998
Resolved 11 March 1998
Construction/Loadline
Issued 11 March 1998Resolved
Crop and renew using good marine practice wasted and holed steel decking inmaster's cabin.
Condition: Unknown
Due 11 March 1998
Resolved 11 March 1998
Construction/Loadline
Issued 11 March 1998Resolved
Renew deteriorated ventilation ducting in engineer's space.
Condition: Unknown
Due 11 March 1998
Resolved 11 March 1998
Construction/Loadline
Issued 11 March 1998Resolved
Renew the aft hatch cover hinges which are unsatisfactory due to deterioration.
Condition: Unknown
Due 11 March 1998
Resolved 11 March 1998
Construction/Loadline
Issued 11 March 1998Resolved
Replace missing stbd cabin water tight door upper hinge bolt nut.
Condition: Unknown
Due 11 March 1998
Resolved 11 March 1998
Fire Fighting
Issued 11 March 1998Resolved
Replace the deteriorated fire extinguisher located on the bridge. Base of fire extinguisher observed to be severely corroded and wasted, a condition under NFPA Standard 10 that requires replacement of the extinguisher.
Condition: Unknown
Due 11 March 1998
Resolved 11 March 1998
Construction/Loadline
Issued 11 March 1998Resolved
Provide appropriate covers to external vents. Covers were previously on vents but not replaced as they deteriorated.
Condition: Unknown
Due 11 March 1998
Resolved 11 March 1998
Construction/Loadline
Issued 11 March 1998Resolved
Replace missing engineroom skylight securing bolts to prevent the undesiredingress of water into the engineroom during stormy weather and high sea conditions.
Condition: Unknown
Due 11 March 1998
Resolved 11 March 1998
Electrical
Issued 23 February 1998Resolved
Interior and exterior light globes and guards were missing or in unsatisfactory condition. New light globes and guards required to be installed not later than 08MAR98.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Engineering
Issued 23 February 1998Resolved
Fuel ventilation flame screens were torn and wasted. Vessel required to renew town/wasted flame screens prior to next oil transfer but not later than 08MAR98.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Construction/Loadline
Issued 23 February 1998Resolved
Vessel's forward scuttle wasted such that the watertight condition of the vessel was not maintained. An approximately 1 inch x 3 inch (H x W) hole was observed. Permanent restoration of the vessel's watertight condition must be accomplished not later than 01MAR98.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998