Inspection history · 64
31 January 2022
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7388297
15 March 2021
Administrative Inspection · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7156501
15 March 2021
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7156737
28 January 2021
Administrative Inspection · Initial Certification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7132526
15 July 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7007199
27 April 2020
MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6944537
6 March 2020
MTSA/ISPS Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6921925
2 December 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6865400
4 September 2019
Initial Certification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6803980
25 August 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6796035
24 August 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6795136
5 June 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6705225
20 April 2019
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6666495
14 March 2019
Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6643187
9 April 2018
Industry Initiated Exam · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6387767
18 October 2017
Administrative Inspection · MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6290272
3 March 2015
DAPI Audit · Industry Initiated Exam · MTSA/ISPS Verification · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5075720
12 December 2013
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4768668
30 May 2013
MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4603691
15 February 2012
DAPI Audit · Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4245294
17 September 2010
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3893454
28 July 2010
Administration · MTSA/ISPS Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3808658
16 January 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3684138
4 September 2008
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3320397
6 June 2008
Administration · MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3228760
29 November 2007
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3106806
24 October 2007
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3086329
5 July 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2984026
28 June 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2981764
23 April 2007
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2913444
3 March 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2883038
10 January 2007
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2857932
4 December 2006
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3880790
26 May 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2659818
23 April 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2640377
19 April 2006
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2629138
19 April 2006
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2629359
6 April 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2649591
15 December 2005
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2559584
23 August 2005
Deficiency Check · MTSA/ISPS Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2471853
9 July 2005
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2497081
30 June 2005
Uninspected Other · MTSA/ISPS Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2474566
20 April 2005
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2338926
7 April 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2328623
8 May 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 768419
28 April 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 210883
26 March 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 768534
27 December 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 768517
10 December 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 210881
10 December 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 210882
9 January 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 86282
26 September 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 47086
6 February 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 165983
19 June 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 126260
12 July 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 9676
3 May 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 110208
9 December 1993
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 848916
9 December 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1160079
15 October 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 68518
6 September 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 127846
5 February 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 148762
10 January 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 152332
3 November 1989
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1232773
12 June 1985
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 439710
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 31 January 2022
Resolved
No vessel owned by the company has a valid COI. Vessel shall obtain a valid COI prior to operation or bring fleet into compliance with 46 CFR 136.202
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 June 2022
Resolution: COI Issued
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 February 2021
Resolved
Fire control panel lapsed on annual servicing requirements.
46 CFR 142.330(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2021
Resolution: See attached doc
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 February 2021
Resolved
Vessel did not have smoke detectors in overnight berthing spaces.
46 CFR 142.330(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2021
Resolution: See docs
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 1 February 2021
Resolved
Generators in machinery space had exposed rotating parts.
46 CFR 144.820
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2021
Resolved 6 July 2022
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 February 2021
Resolved
Vessel did not have required blood pressure reading instruments as indicated in CFR.
46 CFR 140.435
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2021
Resolved 6 July 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 February 2021
Resolved
Flammable and combustible products must not be stored in machinery spaces. MI's found flammable/combustable products in machinery spaces.
46 CFR 143.220
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2021
Resolution: See Docs
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 February 2021
Resolved
40-B portable fire extinguisher must be located near the storage room or cabinet. Vessel had 3 existing paint lockers on aft deck with 1 hard piped in existing locker.
46 CFR 142.225(d)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2021
Resolution: See Docs
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 February 2021
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. MI's found electrical cables transits without blanks installed in panels and junction boxes without covers in machinery space.
46 CFR 142.225(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2021
Resolved 6 July 2022
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 16 October 2019
Resolved
The master, owner, operator, agent, or person in charge
of a vessel equipped with ballast tanks that operates in
the waters of the United States must employ one of the
five ballast water management methods per 33 CFR
151.2025(a). Effective immediately, when operating in the waters of the United States, ballast water exchanges are no longer authorized as one of the five methods since the vessel
is overdue for compliance with a Ballast Water
Management (BWM) system, extension expired on August 20,
2019 without an approved extension renewal. 33 CFR 151.2020, 33 CFR 151.2025(a).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 6 July 2022
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 25 August 2019
Resolved
02199-Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must: be maintained to ensure proper operation. Vessel experienced a broken jockey bar. Provide navigation assessment and repair plan to include a thorough inspection report of any damage to the attachments of the broken jockey bar. Once repairs have been conducted, provide a technician's report attesting to satisfactory repairs and sea trials. 46 CFR 143.205 (c)(1). 60c
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 September 2019
Resolution: Report from ABS states the repairs were completed to class specifications.
Engineering › Steering Gear System › Feedback Unit
Issued 9 July 2005
Resolved
Vessel experienced Steering Casualty in Houston Ship Channel.
Action required: 705 - Other - as specified
Resolved 10 July 2005
Resolution: Received technicians report attesting to proper operation. Inspected and tested steering gear. All Sat.