MAURY USCG vessel records
← All vessels

CROSBY KNIGHT

Built
1975
Last inspected
31 January 2022
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 31 January 2022
…with no type recorded38
Operational controls None recorded without a removal date
Years with a record 24 calendar years (1985–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7390777
WDL8460
134231
Flag
UNITED STATES
Maury page id
psix-134231

Documentation record

Registered dimensions (L × B × D)138.0 ft × 40.0 ft × 13.9 ft
Registered tonnagegross 173 / net 117
ITC dimensions (L × B × D)141.9 ft × 40.0 ft × 22.0 ft
ITC tonnagegross 822 / net 246
BuilderEQUITABLE EQUIPMENT COMPANY INC · MADISONVILLE, LA, UNITED STATES · built 1975
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 1 August 2025 · expires 30 September 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it173 - Regulatory (Subpart C or D), Gross Ton
822 - Convention (Subpart B), Gross Ton
117 - Regulatory (Subpart C or D), Net Ton
246 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 64 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 4 other vessels inspected with it; 2 other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 4

Inspection history · 64

31 January 2022 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7388297
15 March 2021 Administrative Inspection · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7156501
15 March 2021 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7156737
28 January 2021 Administrative Inspection · Initial Certification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7132526
15 July 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7007199
27 April 2020 MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6944537
6 March 2020 MTSA/ISPS Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6921925
2 December 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6865400
4 September 2019 Initial Certification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6803980
25 August 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6796035
24 August 2019 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6795136
5 June 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6705225
20 April 2019 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6666495
14 March 2019 Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6643187
9 April 2018 Industry Initiated Exam · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6387767
18 October 2017 Administrative Inspection · MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6290272
3 March 2015 DAPI Audit · Industry Initiated Exam · MTSA/ISPS Verification · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5075720
12 December 2013 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4768668
30 May 2013 MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4603691
15 February 2012 DAPI Audit · Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4245294
17 September 2010 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3893454
28 July 2010 Administration · MTSA/ISPS Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3808658
16 January 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3684138
4 September 2008 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3320397
6 June 2008 Administration · MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3228760
29 November 2007 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3106806
24 October 2007 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3086329
5 July 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2984026
28 June 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2981764
23 April 2007 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2913444
3 March 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2883038
10 January 2007 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2857932
4 December 2006 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3880790
26 May 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2659818
23 April 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2640377
19 April 2006 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2629138
19 April 2006 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2629359
6 April 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2649591
15 December 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2559584
23 August 2005 Deficiency Check · MTSA/ISPS Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2471853
9 July 2005 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2497081
30 June 2005 Uninspected Other · MTSA/ISPS Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2474566
20 April 2005 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2338926
7 April 2005 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2328623
8 May 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 768419
28 April 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 210883
26 March 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 768534
27 December 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 768517
10 December 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 210881
10 December 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 210882
9 January 2000 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 86282
26 September 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 47086
6 February 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 165983
19 June 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 126260
12 July 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 9676
3 May 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 110208
9 December 1993 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 848916
9 December 1993 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1160079
15 October 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 68518
6 September 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 127846
5 February 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 148762
10 January 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 152332
3 November 1989 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1232773
12 June 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 439710

Deficiency record · 11

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 31 January 2022 Resolved
No vessel owned by the company has a valid COI. Vessel shall obtain a valid COI prior to operation or bring fleet into compliance with 46 CFR 136.202
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 June 2022
Resolution: COI Issued
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 February 2021 Resolved
Fire control panel lapsed on annual servicing requirements. 46 CFR 142.330(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2021
Resolution: See attached doc
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 February 2021 Resolved
Vessel did not have smoke detectors in overnight berthing spaces. 46 CFR 142.330(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2021
Resolution: See docs
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 1 February 2021 Resolved
Generators in machinery space had exposed rotating parts. 46 CFR 144.820
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2021
Resolved 6 July 2022
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 February 2021 Resolved
Vessel did not have required blood pressure reading instruments as indicated in CFR. 46 CFR 140.435
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2021
Resolved 6 July 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 February 2021 Resolved
Flammable and combustible products must not be stored in machinery spaces. MI's found flammable/combustable products in machinery spaces. 46 CFR 143.220
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2021
Resolution: See Docs
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 February 2021 Resolved
40-B portable fire extinguisher must be located near the storage room or cabinet. Vessel had 3 existing paint lockers on aft deck with 1 hard piped in existing locker. 46 CFR 142.225(d)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2021
Resolution: See Docs
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 February 2021 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. MI's found electrical cables transits without blanks installed in panels and junction boxes without covers in machinery space. 46 CFR 142.225(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2021
Resolved 6 July 2022
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 16 October 2019 Resolved
The master, owner, operator, agent, or person in charge of a vessel equipped with ballast tanks that operates in the waters of the United States must employ one of the five ballast water management methods per 33 CFR 151.2025(a). Effective immediately, when operating in the waters of the United States, ballast water exchanges are no longer authorized as one of the five methods since the vessel is overdue for compliance with a Ballast Water Management (BWM) system, extension expired on August 20, 2019 without an approved extension renewal. 33 CFR 151.2020, 33 CFR 151.2025(a).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 6 July 2022
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 25 August 2019 Resolved
02199-Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must: be maintained to ensure proper operation. Vessel experienced a broken jockey bar. Provide navigation assessment and repair plan to include a thorough inspection report of any damage to the attachments of the broken jockey bar. Once repairs have been conducted, provide a technician's report attesting to satisfactory repairs and sea trials. 46 CFR 143.205 (c)(1). 60c
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 September 2019
Resolution: Report from ABS states the repairs were completed to class specifications.
Engineering › Steering Gear System › Feedback Unit
Issued 9 July 2005 Resolved
Vessel experienced Steering Casualty in Houston Ship Channel.
Action required: 705 - Other - as specified
Resolved 10 July 2005
Resolution: Received technicians report attesting to proper operation. Inspected and tested steering gear. All Sat.

Recorded names · 2

PAUL T. MORAN (2005–2019), M.A.R.S. WAR MACHINE (2021). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.