Records from 1985 to 2026. Most recent: operational control imposed, 10 March 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the tow units, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 99
10 March 2026
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8324192
23 June 2025
Load Line/Change of Employment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8160169
18 July 2016
Deficiency Check · COI Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5941579
7 January 2016
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5793940
30 September 2015
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5732413
9 April 2015
MTSA Verification · Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5101977
27 June 2014
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4901920
25 April 2014
Deadweight Survey · Damage Survey · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4871004
21 April 2014
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4847947
11 June 2013
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4617531
29 November 2012
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4493106
27 August 2012
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4423853
17 June 2011
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4047807
14 June 2010
Administrative Inspection · MARPOL Annex I Examination · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3766287
11 February 2010
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3679523
14 May 2009
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3474795
9 March 2009
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3432899
25 March 2008
Internal Structural Exam · Hull Examination · MARPOL Annex I Examination · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3163642
15 March 2008
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3166436
30 March 2007
MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2898379
16 August 2006
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2751864
25 May 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2658359
12 January 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2565538
21 December 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2558208
1 April 2005
MTSA Verification · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2324746
1 March 2005
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2298753
1 November 2004
Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2232236
2 July 2004
MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2118490
26 March 2004
Internal Structural Exam · Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2031346
5 March 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2018948
13 February 2004
Security Plan Review - VSP
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2006451
13 February 2004
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2006455
29 May 2003
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1804520
22 May 2003
COI Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1798793
28 April 2003
Administrative Inspection
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1781912
25 April 2003
Administrative Inspection
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1780466
16 December 2002
Periodic Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1719642
25 October 2002
Type not recorded
No type recorded · Activities Europe · Activity 1695855
9 May 2002
Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1613653
11 January 2002
Internal Structural Exam
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1476295
7 June 2001
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1415628
30 January 2001
Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1056485
31 August 2000
Hull Examination · COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1423483
20 January 2000
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1452615
12 April 1999
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1122667
13 March 1999
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 805876
30 December 1998
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1368980
6 March 1998
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 785354
8 March 1997
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1091417
25 February 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1447680
24 February 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 12121
2 January 1997
COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1425846
30 April 1996
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1081286
28 September 1995
Examination of Repairs · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1446253
15 September 1995
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1182314
21 June 1995
Permit to Proceed · Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1454236
19 June 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 126260
16 March 1995
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1371025
16 March 1994
Re-Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1165564
18 March 1993
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 481653
17 February 1993
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 833485
5 February 1993
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 86070
15 July 1992
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 519789
8 July 1992
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 76895
6 March 1992
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1009317
5 February 1992
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1259386
28 January 1992
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 943075
28 October 1991
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1251025
16 October 1991
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 643102
7 October 1991
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 937819
12 March 1991
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 905878
22 February 1991
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1235111
16 March 1990
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 924795
23 July 1989
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 528075
21 April 1989
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 886894
31 March 1989
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1203020
8 March 1989
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1207337
23 August 1988
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1345146
5 August 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 527531
23 June 1988
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 894164
27 February 1988
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 448070
5 February 1988
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 450458
8 January 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 507130
5 December 1987
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 471698
28 November 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 490660
24 October 1987
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 496511
16 October 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 524978
31 July 1987
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 449926
24 July 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 473450
30 January 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 495260
14 November 1986
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 485564
7 November 1986
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 437571
12 September 1986
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 505659
21 August 1986
Credit Drydock · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1294365
20 June 1986
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 535161
7 June 1986
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 490620
30 May 1986
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 455424
8 August 1985
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 989595
17 July 1985
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 988692
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 18 July 2016
No resolution recorded
Vessel has pending worklist items from 10APR15 Sector Seattle inspection to be cleared before 11OCT16.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 October 2016 — due date passed with no resolution recorded
Deck/Cargo › Cargo Stowage › General
Issued 18 July 2016
Resolved
Remove fuel tank, generator container, and head box.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 22 July 2016
Resolution: Fuel tank and head box removed.
Operations/Management › Ballast Water Managment › Ballast Water Discharge
Issued 18 July 2016
Resolved
Ensure all ballast piping skin valves are blanked off.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2016
Resolution: Port engineer provided photo of blanked ballast valves.
Construction/Loadline › Penetrations › Weld
Issued 25 April 2014
Resolved
Make permanent repairs to damaged areas in #1 Port & #1 Starboard Voids, To the satisfaction of attending Marine Inspector.
Condition: Damaged By Earlier Event
Due 2 June 2014
Resolved 27 June 2014
Resolution: Notified by ABS surveyer that #1 port and #1stbd wing void was repaired. 2'' X4'' insert on port and stbd side. NDT conducted and approved by ABS surveyor. Class certificate and loadline endorsed. Inspection complete.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 27 August 2012
Resolved
Inspections of records showed that the vessels International Load Line Certificated was not properly endorsed by class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2012
Resolution: ABS veirified and endorsed load line cert.
Electrical › Electric Generation Source (service) › Generator
Issued 27 August 2012
Resolved
Vessel representative was unalble to test run electrial generator on board.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2012
Resolution: Vessels rep was on hand and test ran electrical generator. All sat.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 27 August 2012
Resolved
Vessel's power distribution panels covers were loose and or missing fasteners to keep securely in place.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2012
Resolution: Fasterners were attached securing covers in place.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 27 August 2012
Resolved
Vessel had numerous electrial junciton boxes with missing plugs to prevent water intrusion.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2012
Resolution: New junction box covers were installed.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 27 August 2012
Resolved
Vessel has numerous stuffing tube connections for outlet boxes missing or cracked.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2012
Resolution: All stuffing tube connections were checked and replaced if found to be cracked.
Construction/Loadline › Structures › Door
Issued 27 August 2012
Resolved
Vessel's weather tight door is wasted and will not allow weather tight seal.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2012
Resolution: New weather tight door was installed and tested.
Construction/Loadline › Structures › Scuttle
Issued 27 August 2012
Resolved
Missing dog on starboard side void cover mid-ship.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2012
Resolution: New dog was installed on void cover.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 August 2012
Resolved
Vessel operated past its annual inspection date of 30 June 2012 without properly notifying the Coast Guard.
Condition: Invalid
Due 27 August 2012
Resolved 27 August 2012
Construction/Loadline › Structures › Scuttle
Issued 2 July 2004
Resolved
wasted upper and lower deck water tight scuttles, replace all. Wasted water tight door at bow wasted, replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 October 2004
Resolved 23 October 2004
Resolution: The following repairs were satisfactory, 835 was cleared
Construction/Loadline › Hull
Issued 26 March 2004
Resolved
Crop and renew the following sections: Side shell #1 stbd saddle tank and #5 framing, frame members (3), upright supports (3) and replace rusted through framing members in #5 outboard side void port side. #2 port wing tank - crack, #1 port wing plating forward of tank on outboard side. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2004
Resolution: Cropped and renewed side shell section of #1 stbd saddle tank and #5 frame. 3 frame members and 3 upright supports in #5 port void outboard. 1 insert in #2 port wing tank. deck plating #1 port wing tank. Air tests on #1 stbd and #1 port tanks, all sat.
Electrical › Electrical Distribution System (service)
Issued 22 May 2003
Resolved
Panel box was missing a blank located amoung the circuit breakers. LEGACY COMPONENT DESC: Panelboard
Condition: Improper Installation
Due 22 June 2003
Resolved 23 May 2003
Resolution: Installed and labeled spare breaker.
Navigation › Collision/Grounding Avoidance
Issued 22 May 2003
Resolved
Vessels anchor light was not functioning at time of inspection. Provide proper operation of anchor light. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper/Lack of Maintenance
Due 22 June 2003
Resolved 23 May 2003
Resolution: Removed requirement; iaw Rule 23 (Nav Rules), vessel will be pushed ahead by tug and rigidly connected as a composite unit. Operator explained that vsl is not left at anchorage without tug, which has required anchor light.
Electrical › Lighting (service)
Issued 22 May 2003
Resolved
Seal several loose junction box wire connections. LEGACY COMPONENT DESC: Outlet Box
Condition: Improper/Lack of Maintenance
Due 22 June 2003
Resolved 23 May 2003
Construction/Loadline › Markings
Issued 22 May 2003
Resolved
Vessel was missing deck mark of assigned load line. LEGACY COMPONENT DESC: Load Line Mark
Condition: Unknown
Due 22 June 2003
Resolved 22 May 2003
Construction/Loadline › Structures
Issued 22 May 2003
Resolved
Vessel representative was directed to correct askew doors located tween deck fwd. LEGACY COMPONENT DESC: Door
Due 22 June 2003
Resolved 22 May 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 22 May 2003
Resolved
vessel representative was directed to replace two sections of railing that was wasted. LEGACY COMPONENT DESC: Deck Rail
Due 22 June 2003
Resolved 23 May 2003
Construction/Loadline › Markings
Issued 22 May 2003
Resolved
Vessel name was worn and very difficult to read. Vessel representative was also directed to repaint vessels name on the stern, port and stbd bow names. LEGACY COMPONENT DESC: Vessel Name/Home Port
Due 22 June 2003
Resolved 22 May 2003
Navigation › Collision/Grounding Avoidance
Issued 22 May 2003
Resolved
Remove anchor light/battery installation at bow. If vessel is anchored without tug attached, portable anchor light must be used iaw Inland Navigation Rules LEGACY COMPONENT DESC: Navigation Lights
Due 23 June 2003
Resolved 27 May 2003
Electrical › Lighting (service)
Issued 16 December 2002
Resolved
Secure worklights to stanchions/brackets as necessary on stbd side main deck. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 January 2003
Resolved 27 May 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 16 December 2002
Resolved
Make railing repairs as necessary on both sides of ramp, and 01 deck. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 January 2003
Resolved 27 May 2003
Electrical › Electrical Distribution System (service)
Issued 16 December 2002
Resolved
Secure shoretie cable with metallic holders iwo aft catwalk (main deck). Cable was found bundled to other conductors with line and plastic wireties. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 January 2003
Resolved 16 December 2002
Electrical › Electrical Distribution System (service)
Issued 16 December 2002
Resolved
Replace #2 light panel door (hinges broken). LEGACY COMPONENT DESC: Switchboard
Action required: 705 - Other - as specified
Due 20 January 2003
Resolved 16 December 2002
Electrical › Electrical Distribution System (service)
Issued 16 December 2002
Resolved
Provide more durable labeling of #1 and #2 lighting panel switches (in lieu of unprotected paper label taped to inside of doors). LEGACY COMPONENT DESC: Switchboard
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 January 2003
Resolved 16 December 2002
Engineering › Bilge Water Management System
Issued 16 December 2002
Resolved
Label bilge valve handles and replace as necessary. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 January 2003
Resolved 27 May 2003
Construction/Loadline › Hull
Issued 11 January 2002
Resolved
MAKE # 3 STARBOARD OUTBOARD VOID AVAILABLE FOR INTERNAL STRUCTURAL EXAM. LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 April 2002
Resolved 9 May 2002
Resolution: CONDUCTED ISE FOR #3 STARBOARD OUTBOARD VOID. FOUND SAT.
Construction/Loadline
Issued 13 March 1999
Resolved
GOUGE OUT BROKEN WELDS AND RE-WELD VARIOUS AREAS IN WAY OF #6 VERTICAL SIDESHELL FRAME IN #1 PORT WING TANK.
Condition: Unknown
Due 13 March 1999
Resolved 13 March 1999
Construction/Loadline
Issued 13 March 1999
Resolved
GOUGE OUT BROKEN WELDS AND RE-WELD VARIOUS AREAS IN WAY OF #13 VERTICAL SIDE SHELL FRAME IN #2 STBD WING TANK.
Condition: Unknown
Due 13 March 1999
Resolved 13 March 1999
Construction/Loadline
Issued 25 February 1997
Resolved
MAKE PERMANENT REPAIRS, IN KIND, TO DAMAGED DECK PLATING IN LANE B ON 02 DECK NLT 11 MAR 97.
Condition: Unknown
Due 25 February 1997
Resolved 25 February 1997
Electrical
Issued 15 September 1995
Resolved
INSTALLATION AND OPERATIONAL TESTING OF INSTALLED GENERATOR TO BE TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 15 September 1995
Resolved 15 September 1995
Construction/Loadline
Issued 15 September 1995
Resolved
INSTALLATION AND OPERATIONAL TESTING OF BALLAST SYSTEM TO BE TO THE SATISFACTION OF COGNIZANT OCMI.
Condition: Unknown
Due 15 September 1995
Resolved 15 September 1995
Construction/Loadline
Issued 15 September 1995
Resolved
CROP AND RENEW TEMPORARY DOUBLER LOCATED ON STBD. SIDE SHELL PLATING JUST BELOW FORWARD LADDER CUPS.
Condition: Unknown
Due 15 September 1995
Resolved 15 September 1995
Construction/Loadline
Issued 21 June 1995
Resolved
VESSEL IS TO PROCEED TO NEXT PORT OF CALL TO EFFECT REPAIRS PRIOR TO TAKINGON CARGO. OPERATOR IS TO CONTACT THE COGNIZANT [name withheld]. REPAIRS ARE TO BE EFFECTED TO THE SATISFACTION OF THE OCMI.
Condition: Unknown
Due 21 June 1995
Resolved 21 June 1995
Navigation
Issued 16 March 1995
Resolved
PROVIDE BATTERIES FOR ALL NAVIGATION LIGHTS AND MAKE AVAILABLE FOR TESTING IN THE PRESENCE OF A CG MARINE INSPECTOR PRIOR TO OPERATING VESSEL AT NIGHTOR IN RESTRICTED VISIBILITY.
Condition: Unknown
Due 16 March 1995
Resolved 16 March 1995
Electrical
Issued 28 January 1992
Resolved
D1: Provide plan for the electrical cable routed from the distribution box on the lower deck portside forward to the deck lights on the upper deck forward.
Condition: Unknown
Due 28 January 1992
Resolved 28 January 1992
Construction/Loadline
Issued 7 October 1991
Resolved
MAKE PERMANENT REPAIRS TO HEAD LOG PLATE AND BRACKETS IN WAY OF CENTERLINE AND STBD FWD RAKE VOIDS.
Condition: Unknown
Due 7 November 1991
Resolved 28 October 1991
Construction/Loadline
Issued 8 March 1989
Resolved
RENEW FR15 INWAY OF SHELL TOP TO BOTTOM, RENEW UPPER AND LOWER DIA. FR15 APPROX. OUTBD 4', RENEW #3SL FROM APPROX 3' FWD OF FR15 TO 1'FWD FR16,CROP AND INSERT SIDESHELL FM SEAM 6"ABV SL3 TO APPROX 7"BELOW SL4 FROM 2'FWD OF FR15 TO 5'AFT OF SAME, CROP AND INSERT FR16 BETW SL 3&4
Condition: Unknown
Due 8 March 1989
Resolved 8 March 1989