BALEARIC GAS is a 2014 tank ship. The Coast Guard has recorded 16 inspections since 2016, most recently in September 2024, along with 6 deficiencies and 3 operational controls.
Records from 2016 to 2024. Most recent: inspection, 18 September 2024.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it20151 - Convention (Subpart B), Gross Ton 6045 - Convention (Subpart B), Net Ton 24292 - Dead Weight, Metric Ton 35352 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 16 January 2021Resolved
74SOLAS (14) SOLAS IX Reg 3 ISM Reg 10 The company and the ship shall comply with the requirements of the International Safety Management Code. For the purpose of this regulation, the requirements of the Code shall be treated as mandatory. The company should ensure that non-conformities are reported, with possible cause (if known). During testing of the fixed gas detection, uncoupled unions were found in the sampling lines with a wrench in the vicinity. When the unions were tightened, a flow fault was found. The vessel's RO subsequently found that there was a clogged flame arrester in the compressor room. PSCO observed objective evidence in the form of loose unions, flow fault and RO report that a non-conformity had been identified, left not corrected and not reported. 50AC
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2021
Resolved 19 February 2021
Resolution: Vessel manager submitted owner statement and result of ABS additional ISM audit.
74SOLAS(14) VII/13.1 IGC Code 13.6.8 A gas carrier shall comply with the requirements of the International Gas Carrier Code...The gas detection equipment should be capable of sampling and analyzing for each sampling head location sequentially at intervals not exceeding 30 minutes...Multiple sampling lines were found to be loose and freely passing air and span gas. After tightening by crew, spaces sampled were showing "flow fault" and unable to sample. 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2021
Resolution: RO attended. Found clogged flame arrester in compressor room.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 January 2021Resolved
74SOLAS(14) II-1/45.11 In tankers, electrical equipment, cables and wiring shall not be installed in hazardous locations unless it conforms with standards not inferior to those acceptable to the organization. Electrical enclosures for ESD near booster pump, port and STBD booster pump controls, heater control, 3P cargo tank gauging device, 1P tank gauging device, center and STBD compressor controls all have cable glands that are loose or freely allow cable to be pulled out. There are no inspection proce3dures or schedule of inspection for electrical equipment in hazardous locations. 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2021
Resolution: RO attended and attested to correction of electrical deficiencies by crew.
10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 15 January 2021Resolved
74SOLAS(14)V/23.1.2 Res 1045(27) Equipment aqnd arrangements for pilot transfer which are installed on or after 1 July 2012 shall comply with the requirements of this regulation, and due regard shall be paid to the standards adopted by the organization. Ladders are being secured at intermediate drafts by shackles at the chucks/steps. Chocks/steps are not a point as strong as the side ropes. 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2021
Resolved 16 January 2021
Resolution: RO attested to instructing vessel how to properly rig ladder.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 January 2021Resolved
74SOLAS(14) VII/13.1 IGC Code 3.6.3 A gas carrier shall comply with the requirements of the International Gas Carrier Code...An audible and visual alarm system to give a warning on both sides ofthe airlock should be provided to indicate if more than one door is moved from the closed position. Airlock alarnm to the motor room did not activate properly with both doors open. 17ac Corrected before PSC team left vsl. 10c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 January 2021
Resolution: Deficiency rectified prior to PSC team leaving the vessel
12 - Dangerous Goods › N/A - No Subsystem › Other (tankers)
Issued 15 January 2021Resolved
74SOLAS(14) VII/13.1 IGC Code 5.6.4 A gas carrier shall comply with the requirements of the International Gas Carrier Code...Emergency shutdown valves in liquid piping should fully close under all service conditions with 30s of activation. Upon testing ESD, port side manifold liquid line. Self closing valve took 50 seconds to close. 17ac Corrected before PSC team left vsl. 10c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 January 2021
Resolution: Deficiency rectified prior to PSC team leaving the vessel
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.