Records from 2015 to 2025. Most recent: operational control imposed, 31 August 2025.
Inspection history · 27
31 August 2025
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8227345
25 August 2025
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8213385
23 August 2025
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8216471
15 July 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7743035
28 January 2023
In-Service Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7628598
18 January 2023
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7623481
31 May 2022
PSC B · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7464156
5 May 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7444716
29 November 2021
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7357496
27 November 2021
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7357853
2 September 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7302787
1 September 2021
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7302030
9 June 2021
Administrative Inspection · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7220650
4 June 2021
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7215252
3 June 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7411517
14 April 2020
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6938732
9 December 2019
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6870504
5 December 2019
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6868260
3 December 2019
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6866052
30 November 2018
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6589381
26 July 2018
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6491482
10 June 2018
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6439874
13 October 2017
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6286930
14 August 2017
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6234006
14 October 2016
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6022286
4 October 2016
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6014955
12 August 2015
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5206936
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 18 January 2023
Resolved
78 MARPOL 17/Annex 1/6.4.1-
The condition of the ship and its equipment shall be maintained to the provisions of the present convention.
Vessel master reported the oily water seperator was inoperable due to broken plastic pipe junction.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2023
Resolved 28 January 2023
Resolution: Verified repairs by service technician. Tested OWS. All SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 September 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulation to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO was informed by master of main engine RPM issue while the vessel is at half and full speed.
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Resolved 27 November 2021
Resolution: Class and Tech report received to satisfaction. See attached.
Engineering › Generator (propulsion/auxiliary-electric) › Auto Transformer Circuitry
Issued 10 June 2018
Resolved
EDG was not able to take load automatically. Had to be manually started to properly function.
Command issued:Code 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 June 2018
Resolved 26 July 2018
Resolution: At Hong Kong on 28th June 2018 deficiency is rectified, Emergency Diesel Generator PCB replaced, all checked and tested with BV surveyor and found OK. BV surveyor issued new Cargo Ship Safety Construction certificate