Records from 1994 to 2026. Most recent: inspection, 5 March 2026.
Documentation record
Registered dimensions (L × B × D)94.0 ft × 24.9 ft × 11.1 ft
Registered tonnagegross 194 / net 122
ITC dimensions (L × B × D)94.3 ft × 25.4 ft × 14.5 ft
ITC tonnagegross 217 / net 65
BuilderGIBBS GAS ENGINE CO. · JACKSONVILLE, FL, UNITED STATES · built 1945
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 29 June 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it217 - Convention (Subpart B), Gross Ton
194 - Regulatory (Subpart C or D), Gross Ton
65 - Convention (Subpart B), Net Ton
122 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 43
5 March 2026
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8320039
24 February 2025
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8083937
29 February 2024
COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7872446
13 October 2022
Internal Structural Exam · Plan Review (Other than "T") · Drydock Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7579702
1 August 2022
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7451822
28 May 2021
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7209029
13 October 2020
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7077109
30 April 2020
Deficiency Check · Initial Certification · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6945753
26 October 2019
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6862510
26 October 2019
Deficiency Check · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6864098
8 January 2015
Administration
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5050755
28 September 2011
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4156732
26 June 2011
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4059600
6 July 2010
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3787678
26 May 2010
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3748430
22 April 2010
Industry Initiated Exam · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3722500
24 April 2004
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2108541
30 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1999933
9 February 2003
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 1743057
16 February 2001
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 484144
2 January 2001
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 12516
20 October 2000
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 438685
6 October 2000
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 501787
22 June 2000
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 467947
23 December 1998
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 511389
8 November 1998
Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 61389
17 July 1998
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 500621
17 July 1998
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 526990
8 May 1998
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 513974
7 December 1996
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 456936
19 November 1996
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 689701
11 October 1996
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 536116
19 August 1996
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 31420
18 June 1996
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 472381
6 June 1996
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 438506
17 April 1996
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 499569
30 March 1996
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 530915
15 March 1996
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 488202
12 January 1996
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 537067
15 May 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 75987
26 August 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 689698
25 August 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 662980
23 August 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 29914
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 March 2026
Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be
fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. The valve must be operable from a safe place outside the space where the valve is installed. During test of fuel shutoff valve, pull handle snapped due to very tight run from actually fuel valve. Repair fuel shutoff and make the run to the valve easier to pull.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 March 2026
Resolution: MI attended vessel. All SAT.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 February 2025
Resolved
Each towing vessel must be equipped with navigation lights, shapes, and sound signals in accordance with the International Regulations for Prevention of Collisions at Sea (COLREGS) or 33 CFR part 84 as appropriate to its area of operation. Vessel was missing aft lower nav light. Vessel replaced and the nav light was tested. All SAT.
Action required: 10 - Deficiency Rectified
Due 24 February 2025
Resolved 24 February 2025
Resolution: Cleared on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 February 2025
Resolved
At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light approved under approval series At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light approved under approval series
161.010 or 161.110, unless the towing ves- sel is limited to daytime operation, in which case no floating electric water light is required. Vessel was missing one of the floating electric lights. Vessel installed new floating light. All. SAT.
Action required: 10 - Deficiency Rectified
Due 24 February 2025
Resolved 24 February 2025
Resolution: Cleared on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 August 2022
Resolved
Ring buoy IVO top deck access ladder found to be wasted. Replace ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 October 2022
Resolution: Replaced ring buoys
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 August 2022
Resolved
Freezer located on the top deck found to have electrical cables not suitably protected from wet and corrosive environments. Make electrical connections permanent and in junction box.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 October 2022
Resolution: Moved freezer to protected space.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 August 2022
Resolved
Electrical switchboard is required to have nonconductive mat provided on the deck in front, and grab handles being made of nonconductive material.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 October 2022
Resolution: Placed non-conductive mat in front of switchboards. Installed wooden grab handles on switchboards.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 30 April 2020
Resolved
PROVIDE LOCK FOR MSD OVERBOARD VALVE.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2020
Resolved 15 May 2020
Resolution: MI verified lock present on valves.
14 - Pollution Prevention › 141 - MARPOL Annex I › Standard discharge connection
Issued 30 April 2020
Resolved
PROVIDE INTERNATIONAL SHORE CONNECTION OR ADAPTER FOR SLUDGE DISCHARGE.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2020
Resolved 15 May 2020
14 - Pollution Prevention › 141 - MARPOL Annex I › Standard discharge connection
Issued 30 April 2020
Resolved
PROVIDE EMREGENCY STOP ON WEATHER DECK FOR SLUDGE DISCHARGE PUMP.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2020
Resolved 13 October 2020
Resolution: Inspected by attending MI.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 April 2020
Resolved
REDUCE COMBUSTIBLE LIQUID STORAGE IN E/R <55 GALLONS AND MOVE FLAMMABLE LIQUID STORAGE <5 GALLONS TO SUITABLE STEEL CONTAINER.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2020
Resolved 15 May 2020
Resolution: MI observed combustibles removed and flammables in proper steel container.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 30 April 2020
Resolved
MARK GENERAL ALARM LIGHT IN E/R WITH "GENERAL ALARM - WHEN LIGHT FLASHES, GO TO YOUR STATION."
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2020
Resolved 15 May 2020
Resolution: MI observed new signage.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 30 April 2020
Resolved
TEST ALARMS LISTED IN PRESENCE OF MARINE INSPECTOR. SEE 46 CFR 143.230.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2020
Resolved 8 June 2020
Resolution: Sensor calibration certificates received.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 April 2020
Resolved
INSTALL CHECK VALVES IN BILGE SYSTEM TO PREVENT UNINTENDED BACK FLOODING.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2020
Resolved 15 May 2020
Resolution: Check valves installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 April 2020
Resolved
CORRECT BILGE DIAGRAMS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2020
Resolved 8 June 2020
Resolution: Diagram corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 April 2020
Resolved
CORRECT PIPE COLOR CODING TO MEET ISO STANDARD 14726
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2020
Resolved 15 May 2020
Resolution: Piping marked with color codes.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 April 2020
Resolved
PERMANENTLY MARK OFFICIAL NUMBER "NO. 565613" ON A VISIBLE INTERIOR HULL STRUCTURE.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2020
Resolved 15 May 2020
Resolution: ON permanently welded at frame at E/R entrance.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 April 2020
Resolved
TEST BILGE PUMPING ARRANGEMENTS FOR SHAFT ALLEY AND LAZARETTE IN PRESENCE OF MARINE INSPECTOR.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2020
Resolved 15 May 2020
Resolution: Lazz and E/R bilge lines tested SAT.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 April 2020
Resolved
RETURN WHEELS TO SEMI-PORTABLE FIRE EXTINGUISHERS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2020
Resolved 15 May 2020
Resolution: Wheels on 01 reinstalled. 2nd is designed without wheels.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 26 October 2019
Resolved
the owner, managing operator, or master of each towing vessel must maintain the required navigational safety equipment in a fully functioning, operational condition. Vessel reported casualty to AIS antenna. Vessel is required to repair and provide proof of proper installation and operation to the satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 October 2019
Resolution: Owner/Opertor repaired the damaged antenna and demonstrated that AIS was functioning properly.