Records from 2014 to 2026. Most recent: inspection, 24 March 2026.
Documentation record
Registered dimensions (L × B × D)543.4 ft × 78.0 ft × 42.0 ft
Registered tonnagegross 11,647 / net 11,647
ITC dimensions (L × B × D)543.4 ft × 78.0 ft × 42.0 ft
ITC tonnagegross 13,954 / net 8,494
BuilderGUNDERSON MARINE LLC · PORTLAND, OR, UNITED STATES · built 2016
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portWILMINGTON, DE
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 14 March 2026 · expires 31 March 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13954 - Convention (Subpart B), Gross Ton
11647 - Regulatory (Subpart C or D), Gross Ton
8494 - Convention (Subpart B), Net Ton
11647 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
24 March 2026
Administrative Inspection · COI Inspection · Cargo Tank Internal · Vessel Attendance · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8320290
8 July 2025
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8178888
14 August 2024
Bulk Liquid Transfer Monitor
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7981219
24 April 2024
Examination of Repairs · Periodic Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7900802
10 July 2023
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7725689
21 July 2022
MTSA Verification · Ballast Water Examination · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7512520
18 March 2021
Cargo Tank Internal · Internal Structural Exam · In-Service Inspection · COI Inspection · Drydock Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7157484
12 September 2020
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7057586
7 September 2020
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7053129
7 September 2020
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7053182
29 June 2020
Annual Inspection · Administrative Inspection · MARPOL Annex II Examination · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6985019
19 October 2019
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6839475
2 June 2019
Periodic Inspection · In-Service Inspection · Deficiency Check · Internal Structural Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6702038
20 April 2018
Annual Inspection · MARPOL Annex II Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6390681
27 November 2017
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6314073
6 November 2017
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6301738
3 May 2017
Annual Inspection · MARPOL Annex II Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6138132
14 July 2016
Explosive Handling Operation-Commercial
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5945042
26 August 2014
Hull Examination · Cargo Tank Internal · Construction Oversight · COI Inspection · Internal Structural Exam · MARPOL Annex I Examination · MARPOL Annex II Examination · Initial Certification
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5864669
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 16 July 2025
Resolved
The master shall ensure that the inert gas systems for any cargo that this part requires to be inerted are operating correctly. MI observed fuel leaking out of main and pilot fuel injectors on IG system.
46 CFR 153.923
Action required: 10 - Deficiency Rectified
Resolved 23 July 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 July 2025
Resolved
Each cargo heating system must meet the standards of Subchapter F (Marine Engineering) of this chapter. Thermal fluid heaters are examined by a marine inspector to determine that the complete unit is in a safe and satisfactory condition. MI observed fuel leaking on thermal fluid heaters port fuel line.
46 CFR 153.430
46 CFR 61.30-15
Action required: 10 - Deficiency Rectified
Resolved 16 July 2025
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 16 July 2025
Resolved
The rules governing the issuance of Certificates of Inspection are contained in part 31 of this chapter. All tank vessels are subject to the regulations contained in subchapter F. At each inspection for certification the MI must conduct such tests and inspections of the auxiliary machinery and of its associated equipment as they feel necessary to check safe operation. MI observed the local emergency shutdown located on the #2 generator and E shutdowns on the switchboard for generators #1 & #3 did not cause the generators to shut down upon activation. Provide manufacturer info on shutdowns.
46 CFR 153.812
46 CFR 31.30-1
46 CFR 61.20-3
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 July 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 July 2025
Resolved
A tankship carrying a flammable or combustible cargo under this part must meet subchapter J. Electric installations on vessels must ensure maintenance of services necessary for safety under normal and emergency
conditions. MI observed moisture in light on starboard, aft section on top of the thermal fluid heater house. Clean and replace fixture.
46 CFR 153.466
46 CFR 111.01-1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 July 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 July 2025
Resolved
If the annual inspection reveals deficiencies in your vessel's maintenance, you must make any or all repairs or improvements within the time period specified by the [name withheld] observed wing nuts on ballast house vents were seized, prohibiting their closure, on both the starboard and port side ballast houses. Re-adjust wing nuts to work properly.
46 CFR 31.10-17
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 July 2025
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 July 2025
Resolved
If the annual inspection reveals deficiencies in your vessel's maintenance, you must make any or all repairs or improvements within the time period specified by the [name withheld] observed wasted gaskets on the starboard cargo engine room. Replace gaskets.
46 CFR 31.10-17
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 July 2025
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 13 June 2024
Resolved
The last 1.0 meter (3.3 feet) of vapor piping upstream of the vessel vapor connection and each end of a vapor hose must be Painted in the sequence of red/yellow/red. The width of the red bands must be 0.1 meter (0.33 foot) and the width of the middle yellow band must be 0.8 meter (2.64 feet) and be labeled with the word "VAPOR" painted in black letters at least 50.8 millimeters (2 inches) high. MI observed vapor lines at the port/stbd manifold were not painted IAW the regulations.
Action required: 705 - Other - as specified
Due 20 June 2024
Resolved 14 June 2024
Resolution: VCS line properly painted.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 13 June 2024
Resolved
The following items are to be examined to determine if in satisfactory condition: Structure of the vessel, coamings, closures, and all means of protection provided for openings, such as for ventilators, companionways, machinery casings, fiddleys, funnels, enclosed superstructures on the freeboard deck (and their end bulkheads) or equivalent protective deck houses, openings in the freeboard and superstructure decks, and significant openings at higher levels in the vessel. MI
observed 01 vent closure on top of the aft/port ballast
house was inoperable.
46 CFR 42.09-25(b)(2)
Action required: 705 - Other - as specified
Due 20 June 2024
Resolved 14 June 2024
Resolution: Closure device was unsiezed.