Records from 1994 to 2026. Most recent: inspection, 5 June 2026.
Inspection history · 54
5 June 2026
COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8392647
14 January 2026
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8296556
30 April 2024
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7904129
11 April 2024
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7893417
15 January 2024
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7849999
28 October 2023
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7816354
28 October 2023
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7831118
6 December 2022
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7605487
3 October 2022
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7571067
27 January 2022
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7386548
1 January 2022
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7378334
11 May 2021
MTSA Verification · Initial Certification · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7194387
4 September 2019
TPO Audit
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6859724
25 March 2019
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6653911
4 April 2018
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6384811
4 July 2015
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5183257
24 June 2013
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4630367
4 March 2013
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4543005
6 February 2013
DAPI Audit
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4529326
28 January 2013
Administration · Industry Initiated Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4524139
15 December 2011
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4218323
7 June 2011
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4089219
17 December 2009
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3651855
7 December 2009
MTSA Verification · MARPOL · Industry Initiated Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3645824
20 April 2009
MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3457217
6 September 2008
Uninspected Other · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3319025
14 December 2007
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3115785
10 December 2007
Uninspected Other · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3113088
6 December 2007
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3110677
27 March 2007
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2896698
26 February 2007
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2877917
28 December 2006
Uninspected Other
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2852880
10 August 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2742887
10 August 2006
Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2742931
1 March 2006
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2593803
16 November 2005
Uninspected Other
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2541580
6 January 2005
MTSA Verification
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2294678
3 November 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979280
9 July 2002
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1745801
16 May 2002
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1628097
31 March 2002
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1618639
20 November 2000
Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1055526
11 April 2000
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 696140
21 March 2000
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 50938
21 March 2000
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 215215
10 November 1999
Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 810529
29 October 1998
Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 808870
29 October 1998
Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1127810
12 January 1998
Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1111938
19 December 1995
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 50711
4 March 1995
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 115860
3 August 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 99351
10 February 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 696144
17 January 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 19650
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 April 2024
Resolved
Fire-detection systems. Except as provided in paragraph (a)(8) of this section, each towing vessel must have a fire-detection system installed to detect engine room fires. The owner or managing operator must ensure the following:
(2) The system is installed, tested, and maintained in accordance with the manufacturer's design manual.
Provide documentation that newly installed heat detectors have been tested in accordance with manufacturer's instructions. Until newly installed heat detectors can be tested, the crew will conduct and log rounds of the engine room every 60 minutes while underway.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 2 May 2024
Resolution: Received Cintas Fire Protection report from [name withheld] that fire detection system has been tested.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 April 2024
Resolved
The design of the system and its installation on the towing vessel is certified and inspected by a registered professional engineer with experience in fire-detection system design, by a technician with qualifications as a National Institute for Certification in Engineering Technologies (NICET) level IV fire alarm engineering technician, or by an authorized classification society with equivalent experience, to comply with paragraphs (a)(1) through (6) of this section.
Provide proof that the current arrangement of the fire detection system to include all newly installed components is certified and inspected by a registered professional engineer with experience in fire-detection system design, by a technician with qualifications as a National Institute for Certification in Engineering Technologies (NICET) level IV fire alarm engineering technician, or by an authorized classification society with equivalent experience. The certification letter must include verification that the fire-detection system as a whole with the new detectors installed, meets the requirements of 46 CFR 142.330(a)(1) thru (6).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2024
Resolved 31 July 2024
Resolution: Received email from [name withheld] with P.E. letter that satisfies the requirements of the 835. P.E. letter uploaded to documents.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 6 September 2008
Resolved
Prove proper operation of fire detection system prior to operation IAW 46CFR27.203.
Action required: 705 - Other - as specified
Resolved 18 September 2008
Engineering › Fuel Oil Service System › Valve
Issued 6 September 2008
Resolved
Prove proper operation of remote fuel shut-offs IAW 46CFR27.207
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 September 2008
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 6 September 2008
Resolved
Prove proper testing of B-V CO2 system IAW 46CFR27.303(b)(1)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 September 2008
Resolved 10 September 2008
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 28 December 2006
Resolved
Fire Detection Panel in pilothouse alarm does not sound as required under 46 CFR27.203. Corrected during inspection on 28 Dec 2006
Condition: Improper/Lack of Maintenance
Due 28 December 2006
Resolved 28 December 2006
Resolution: Repairs made sound from Fire Detection Panel now working.
Fire Fighting › Remote Fuel Shutoff › General
Issued 28 December 2006
Resolved
Remote Fuel Oil Shut off valve control needs to be marked in clearly legible letters indicating the purpose of the valve and the way to operate it.
Condition: Improper/Lack of Maintenance
Due 29 January 2007
Resolved 26 February 2007
Resolution: Valve now marked.
Fire Fighting › Fixed Fire Detection System › Approval
Issued 16 November 2005
Resolved
Provide proof Fire Detection system in engine room is certified by a licensed professional engineer or letter form a classification society as required under 46 CFR 27.203(g)
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 February 2006
Resolved 21 February 2006
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 16 November 2005
Resolved
Fire detection panel in pilothouse alarm does not sound or alarm.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 February 2006
Resolved 21 February 2006