MAURY USCG vessel records
← All vessels

KIRBY 12503B

Built
2008
Last inspected
2 October 2023
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 2 October 2023
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 14 calendar years (2008–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

921390
Flag
UNITED STATES
Maury page id
psix-921390

Documentation record

Registered dimensions (L × B × D)200.0 ft × 35.0 ft × 12.5 ft
Registered tonnagegross 735 / net 735
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWEST GULF MARINE LTD · PALACIOS, TX, UNITED STATES · built 2008
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portWILMINGTON, DE
Endorsements, as the file codes themcw_un
DocumentationValid · issued 16 July 2026 · expires 31 August 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it735 - Simplified, Gross Ton
735 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 20 inspections, each with its date, unit and type; 4 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 10 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 10

Inspection history · 20

2 October 2023 MTSA Verification · Internal Structural Exam · COI Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7798260
10 November 2020 Administrative Inspection
Administrative · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7092979
25 March 2019 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6653911
24 August 2018 Cargo Tank Internal · Drydock Exam · Examination of Repairs · COI Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6524576
5 October 2017 Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6282042
5 June 2017 Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6185838
18 July 2016 Annual Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5939432
22 June 2016 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5917641
17 September 2015 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5730412
27 August 2015 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5231037
27 May 2015 Periodic Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5137203
12 June 2014 Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4941647
29 August 2013 MTSA Verification · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4698841
6 June 2012 MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4393897
10 June 2011 MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4135718
1 July 2010 Periodic Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3782051
1 June 2009 Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3540490
13 November 2008 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3362490
31 July 2008 Construction Oversight
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3284853
31 July 2008 Initial Certification · MTSA Verification
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3284854

Deficiency record · 4

Construction/Loadline › Hull › Hull Plating
Issued 23 June 2016 Resolved
Provide Marine Chemist to certify bow void for further internal structural inspection prior to loading cargo. 46 CFR 2.01-10(e)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 July 2016
Resolved 18 July 2016
Resolution: Entered bow box and inspected repairs. Witnessed 1.5 psi soap test of repair with satisfactory results.
Communications › Visual Communication › Warning Sign (gangway)
Issued 27 August 2015 Resolved
Provide onboard proper cargo sign labe, with proper cargo name visiable and readable per 46 CFR 151.45-2(e)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 September 2015
Resolved 17 September 2015
Communications › Visual Communication › Warning Sign (gangway)
Issued 27 August 2015 Resolved
Provide onboard cargo infomation card mounted so that it can be easily read. 7"x9.5" pe 46 CFR 151.45-2(e)(3)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 September 2015
Resolved 17 September 2015
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 27 August 2015 Resolved
Provide onboard Coast Guard approved extinguishers with brackets per 46 CFR 34.05-10 and 46 CFR 162.028-3(g)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 September 2015
Resolved 17 September 2015

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.