Records from 2016 to 2025. Most recent: inspection, 10 December 2025.
Documentation record
Registered dimensions (L × B × D)482.8 ft × 96.0 ft × 51.0 ft
Registered tonnagegross 18,042 / net 18,042
ITC dimensions (L × B × D)482.8 ft × 96.0 ft × 51.0 ft
ITC tonnagegross 18,777 / net 5,633
BuilderVIGOR FAB LLC · PORTLAND, OR, UNITED STATES · built 2017
Hull materialSteel
PropulsionNot recorded
Hull shapeShip
Hull configurationMonohull
Hailing portTAMPA, FL
Trade endorsementsCoastwise, charter, Registry
DocumentationValid · issued 7 August 2026 · expires 31 August 2027
Service, as the file records itTank Barge
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18777 - Convention (Subpart B), Gross Ton
18042 - Regulatory (Subpart C or D), Gross Ton
5633 - Convention (Subpart B), Net Ton
18042 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
10 December 2025
MARPOL Annex VI Survey · Deficiency Check · Periodic Inspection · MTSA Verification · MARPOL Annex I Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8281767
14 October 2025
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8251975
9 July 2025
Vessel Attendance · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8182121
9 December 2024
Annual Inspection · MARPOL Annex VI Survey · MARPOL Annex I Examination · MTSA Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8040337
8 December 2023
MARPOL Annex VI Survey · Annual Inspection · MARPOL Annex I Examination · MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7828187
8 August 2022
Internal Structural Exam · Examination of Repairs · Hull Examination · COI Inspection · Cargo Tank Internal · MTSA Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7484015
24 December 2021
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7372178
4 June 2021
MARPOL Annex VI Survey · MARPOL Annex I Examination · Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7215412
18 May 2020
MARPOL Annex I Examination · Internal Structural Exam · MARPOL Annex VI Survey · Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6955388
6 September 2019
Annual Inspection · MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6795443
22 August 2019
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6792394
23 April 2019
Construction Oversight
Physical examination · Activities Europe · Activity 6657828
10 August 2018
MARPOL Annex I Examination · Annual Inspection · MARPOL Annex VI Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6507476
2 January 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6331617
25 September 2017
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6274354
14 April 2017
Construction Oversight · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6124405
15 April 2016
Construction Oversight · Uninspected Other
Physical examination · Activities Europe · Activity 5858212
19 January 2016
MARPOL Annex I Examination · Initial Certification · Cargo Tank Internal · Drydock Exam · Construction Oversight · MTSA Verification · Internal Structural Exam · MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5800003
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 10 December 2025
Resolved
46 CFR 38.10-10 (c)
Piping shall be provided with adequate support to take the weight of the piping off valves and fittings and to prevent excessive vibration and stresses on tank connections. MI observed that 75% of pipe securing brackets were missing or broken. Enact repairs to the satisfaction of USCG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 December 2025
Resolved 15 December 2025
Resolution: Brackets were replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 December 2025
Resolved
46 CFR 31.35-1
46 CFR 111.105-31 (m)
Locations in the weather are Class I, Division 1 (Zone 1) locations may have only approved intrinsically safe, explosion proof, or purged and pressurized electrical equipment, and through runs of marine shipboard cable. MI observed multiple cable glands on electrical equipment in the hazardous zone that had failed which compromises intrinsically safe, explosion proof capabilities. Locations are most forward white and yellow port side lights on center cat walk railing, #1 cargo tank call back system, #3 port cargo pump small aft cable gland, #4 port cargo pump small fwd cable gland. Enact permanent repairs to the satisfaction of USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 December 2025
Resolved 15 December 2025
Resolution: Cable glands were repaired.
14 - Pollution Prevention › 148 - Ballast Water › Ballast water discharge
Issued 14 October 2025
Resolved
The master, owner, operator, agent, or person in charge of a vessel equipped with ballast tanks that operates in the waters of the United States must employ one of the following ballast water management methods:Install and operate a ballast water management system (BWMS) that has been approved by the Coast Guard under 46 CFR part 162. The BWMS must be installed in accordance with § 151.2035(b) of this subpart. Following installation, the master, owner, operator, agent, or person in charge of the vessel subject to this subpart must properly maintain the BWMS in accordance with all manufacturer specifications. Unless otherwise expressly provided for in this subpart, the master, owner, operator, agent, or person in charge of vessels employing a Coast Guard-approved BWMS must meet the applicable ballast water discharge standard (BWDS), found in § 151.2030 of this subpart, at all times of discharge into the waters of the United States. The vessel's current Ballast Water Management System (BWMS) software is not accurately administering the correct dosage. The vessel has been granted a one-time authorization to discharge ballast water in Freeport, TX.
Enact repairs to the satisfaction of the Coast Guard Provide a repair plan to [email withheld]
Action required: 15 - Rectify deficiencies by next port
Due 14 October 2025
Resolved 31 October 2025
Resolution: Received ABS report that new BWMS was commissioned and tested satisfactory.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 9 December 2024
Resolved
46 CFR 38.10-20 (a)
Each tank shall be fitted with a liquid level gaging device of approved design to indicate the maximum level to which the tank may be filled with liquid. MI observed that the liquid level gaging in #3 cargo tank was not operational. Vessel shall enact permanent repairs to the satisfaction of USCG Marine Inspector. Vessel is restricted from carrying cargo in #3 cargo tank.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 December 2024
Resolved 11 December 2024
Resolution: Received tech report attesting to operational tank level indicator.
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 21 July 2017
Resolved
Resubmit the vessel’s DVT/QFA/PSTP procedures, with annotations, corrections,and deletions results from on-site testing witnessed by MSU Portland inspectors and ABS,, to the Coast Guard’s Marine Safety Center for final review and approval. This requirement will be satisfied upon receipt of MSC approval letter. Ref: MSC letter E2-1702111 dated 15JUN17 (46 CFR 62)
Due 30 September 2017
Resolved 2 January 2018
Deck/Cargo › Cargo Refrigeration › General
Issued 21 July 2017
Resolved
Prove proper operation of the “High” level alarm in the VIMEX alarm system for #3 cargo tank, STBD half, to the satisfaction of the attending CG marine inspector. The Krohne fixed gauging system’s 95% high level alarm was tested and found fully functional (audible and visual). (46 CFR 62/46 CFR 32.20-20)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 25 September 2017
Resolution: Deficiency corrected to satisfaction of attending Coast Guard Marine Inspector.