Records from 2016 to 2026. Most recent: inspection, 7 June 2026.
Inspection history · 16
7 June 2026
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8385342
4 November 2025
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8269499
2 September 2025
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8266986
3 August 2025
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8201056
15 June 2025
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8152711
29 May 2025
In-Service Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8146636
26 October 2024
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8022494
14 August 2023
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7768346
19 March 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7653118
18 December 2021
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7373608
14 December 2021
PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7366954
24 April 2019
ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6664514
11 June 2018
ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6436334
15 October 2017
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6287736
11 June 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5904085
29 March 2016
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5839764
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 3 August 2025
Resolved
EACH VESSEL MUST HAVE THE FOLLOWING: AN ECHO DEPTH SOUNDING DEVICE. THE VESSEL'S ECHO DEPTH SOUNDING DEVICE WAS REPORTED AS NON-OPERATIONAL AND A SPARE PART IS UNAVAILABLE FOR ORDER.
33CFR164.35(h)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2025
Resolved 11 November 2025
Resolution: Echo depth sounder display replaced thus rectifying def.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 29 May 2025
Resolved
Ships shall be designed, constructed, and maintained in compliance with the structural requirements of a classification society. PSCO observed a significant inset on the hull, starboard side, frame 235 directly above the waterline. 74SOLAS(20)II-1/3-1
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 May 2025
Resolution: LR attended vessel and completed inspection of hull's interior at the location of damage and imposed condition of class for permanent repair by 19OCT25. Integrity of vessel is considered efficient. Deficiency reissued as Code 705ac (See Item Number 3).
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 14 December 2021
Resolved
BEFORE THE SHIP LEAVES PORT AND ALL TIMES DURING THE VOYAGE ALL LIFE-SAVING APPLIANCIES SHALL BE IN WORKING ORDER AND READY FOR USE. PORT SIDE LIFERAFTS WERE SECURED WITH THREE CHAINS TO THE DECK WITH SHACKLES, MAKING THE LIFERAFTS NOT READY FOR IMMEDIATE USE.
SOLAS 74(2020 CONS)III/20.2
74SOLAS(20) III/20.2
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 14 December 2021
Resolved 14 December 2021
Resolution: Rectified to the satisfaction of the Coast guard
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 April 2019
Resolved
07199- The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose the following functional requirement shall be met: means shall be provided to control leaks of flammable liquids. PSCO observed leakage on both the dual strainers and common header of the fuel oil pumping system.
74 SOLAS(14)II-2/4.1.1 60a
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 April 2019
Resolution: 25APR19: Recieved, reviewed and approved DNV-GL class report. 01 Deficiency cleared.