MAURY USCG vessel records
← All vessels

KEN UN

KEN UN is a 2015 freight ship. The Coast Guard has recorded 18 inspections since 2016, most recently in November 2025, along with 6 deficiencies and 4 operational controls.

Records from 2016 to 2025. Most recent: inspection, 21 November 2025.

Built
2015
Last inspected
21 November 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 November 2025
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9727089
1374666
Flag
PANAMA
Maury page id
psix-1374666

Documentation record

Tonnage as PSIX records it37429 - Dead Weight, Metric Ton
44964 - Displacement, Metric Ton
22501 - Convention (Subpart B), Gross Ton
12174 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 12

Inspection history · 18

21 November 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8272349
12 November 2025 PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8267400
30 April 2025 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8120796
29 April 2025 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8123121
29 April 2025 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8129511
27 April 2025 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8120790
22 April 2025 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8117191
29 January 2024 PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7857098
30 March 2022 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7421600
15 May 2020 PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6953687
1 May 2020 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6946790
20 September 2018 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6539579
5 August 2018 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6501045
13 March 2017 ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6103906
7 March 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6095265
19 October 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6025944
20 May 2016 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5882370
20 May 2016 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5885856

Deficiency record · 6

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 30 April 2025 Resolved
In addition to the requirements contained elsewhere in the present regulations, ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a class society which is recognized by the administration. As a result of an allision, vessel has substantial damage to the hull at the port aft fresh water tank. Effect repair to the satisfaction of classification society and administration. 74 SOLAS (amend.) II-1/3-1 17 ac
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2025
Resolved 15 May 2025
Resolution: Vessel underwent permanent repair of hull. Shell plating and frame member in the affected area were cropped and renewed. NDT and hydraulic test were carried out to the satisfaction of the Class Society, and report accepted by the attending PSCO.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 April 2025 Resolved
A fixed fire-extinguishing system required by paragraph 5 below may be any of the following systems: a fixed pressure water-spraying fire-extinguishing system complying with the provisions of the Fire Safety Systems Code. Water mist fire-extinguishing systems for machinery spaces and cargo pump rooms shall be approved by the administration based on the guidelines developed by the organization. Water mist system unable to be operated as designed due to tank breach. Return to full service to the satisfaction of classification society. 74 SOLAS (amend.) II-2/10.4.1.1.3 FSS 7.2.2 17 ac
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2025
Resolved 15 May 2025
Resolution: Repairs to the affected fresh water tank were conducted, and water mist system was operationally tested by Class and working as designed. Class report reviewed and accepted by attending PSCO.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 30 April 2025 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed port and starboard lifeboats unable to clutch ahead and astern without removing engine cover and adjusting associated cables. Repair or maintain such that lifeboats are ready for immediate use. 74 SOLAS (amend.) III/20.2 17 ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2025
Resolved 15 May 2025
Resolution: Port and stbd lifeboats were tested by Class and found to be operational.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 April 2025 Resolved
The purpose of this regulation is to contain a fire in the space of origin. For this purpose, the following functional requirements shall be met: the fire integrity of the divisions shall be maintained at openings and penetrations. PSCO observed both doors leading from the engine room into the steering gear room lashed open. Ship's crew removed temporary hold backs. 74 SOLAS (amend.) II-2/9.1.3 10 c
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 30 April 2025
Resolved 30 April 2025
Resolution: Ship's crew removed door hold backs to the satisfaction of the attending PSCO.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 30 April 2025 Resolved
The steering gear compartments shall be: provided with suitable arrangements to ensure working access to steering gear machinery and controls. These arrangements shall include handrails and gratings or other nonslip surfaces to ensure suitable working conditions in the event of hydraulic fluid leakage. PSCO observed hydraulic oil-covered and slippery surfaces in the vicinity of steering gear. Crew completed cleanups of slippery surfaces. 74 SOLAS (amend.) II-1 29/13.2 10 c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 April 2025
Resolved 30 April 2025
Resolution: Ship's crew completed cleanups of slippery surfaces to the satisfaction of the attending PSCO.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 22 April 2025 Resolved
Each Vessel of 10,000 gross tons or more must have, in addition to the radar system under 164.35(a) a second marine radar system that operates independantly of the first. Vessel reports S -band radar malfunction while preparing to depart the port.
Action required: 15 - Rectify deficiencies by next port
Resolved 2 May 2025
Resolution: SECTOR NEW ORLEANS received Technician report that satisfies the deficiency.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.