Records from 2015 to 2025. Most recent: inspection, 21 November 2025.
Inspection history · 19
21 November 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8272349
12 November 2025
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8267400
30 April 2025
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8120796
29 April 2025
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8123121
29 April 2025
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8129511
27 April 2025
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8120790
22 April 2025
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8117191
29 January 2024
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7857098
30 March 2022
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7421600
15 May 2020
PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6953687
1 May 2020
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6946790
20 September 2018
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6539579
5 August 2018
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6501045
13 March 2017
ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6103906
7 March 2017
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6095265
19 October 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6025944
20 May 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5882370
20 May 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5885856
2 December 2015
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5772383
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 30 April 2025
Resolved
In addition to the requirements contained elsewhere in the present regulations, ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a class society which is recognized by the administration. As a result of an allision, vessel has substantial damage to the hull at the port aft fresh water tank. Effect repair to the satisfaction of classification society and administration.
74 SOLAS (amend.) II-1/3-1
17 ac
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2025
Resolved 15 May 2025
Resolution: Vessel underwent permanent repair of hull. Shell plating and frame member in the affected area were cropped and renewed. NDT and hydraulic test were carried out to the satisfaction of the Class Society, and report accepted by the attending PSCO.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 April 2025
Resolved
A fixed fire-extinguishing system required by paragraph 5 below may be any of the following systems: a fixed pressure water-spraying fire-extinguishing system complying with the provisions of the Fire Safety Systems Code.
Water mist fire-extinguishing systems for machinery spaces and cargo pump rooms shall be approved by the administration based on the guidelines developed by the organization. Water mist system unable to be operated as designed due to tank breach. Return to full service to the satisfaction of classification society.
74 SOLAS (amend.) II-2/10.4.1.1.3
FSS 7.2.2
17 ac
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2025
Resolved 15 May 2025
Resolution: Repairs to the affected fresh water tank were conducted, and water mist system was operationally tested by Class and working as designed. Class report reviewed and accepted by attending PSCO.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 30 April 2025
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed port and starboard lifeboats unable to clutch ahead and astern without removing engine cover and adjusting associated cables. Repair or maintain such that lifeboats are ready for immediate use.
74 SOLAS (amend.) III/20.2
17 ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2025
Resolved 15 May 2025
Resolution: Port and stbd lifeboats were tested by Class and found to be operational.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 April 2025
Resolved
The purpose of this regulation is to contain a fire in the space of origin. For this purpose, the following functional requirements shall be met: the fire integrity of the divisions shall be maintained at openings and penetrations. PSCO observed both doors leading from the engine room into the steering gear room lashed open. Ship's crew removed temporary hold backs.
74 SOLAS (amend.) II-2/9.1.3
10 c
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 30 April 2025
Resolved 30 April 2025
Resolution: Ship's crew removed door hold backs to the satisfaction of the attending PSCO.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 30 April 2025
Resolved
The steering gear compartments shall be: provided with suitable arrangements to ensure working access to steering gear machinery and controls. These arrangements shall include handrails and gratings or other nonslip surfaces to ensure suitable working conditions in the event of hydraulic fluid leakage. PSCO observed hydraulic oil-covered and slippery surfaces in the vicinity of steering gear. Crew completed cleanups of slippery surfaces.
74 SOLAS (amend.) II-1 29/13.2
10 c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 April 2025
Resolved 30 April 2025
Resolution: Ship's crew completed cleanups of slippery surfaces to the satisfaction of the attending PSCO.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 22 April 2025
Resolved
Each Vessel of 10,000 gross tons or more must have, in addition to the radar system under 164.35(a) a second marine radar system that operates independantly of the first. Vessel reports S -band radar malfunction while preparing to depart the port.
Action required: 15 - Rectify deficiencies by next port
Resolved 2 May 2025
Resolution: SECTOR NEW ORLEANS received Technician report that satisfies the deficiency.