Records from 2018 to 2025. Most recent: inspection, 10 December 2025.
Inspection history · 19
10 December 2025
Hull Examination · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8280368
11 November 2025
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8318412
9 October 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8249896
1 October 2025
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8244705
22 October 2024
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8022821
11 September 2024
Deadweight Survey · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8000540
28 December 2023
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7842981
13 July 2023
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7741591
23 June 2023
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7721548
7 October 2022
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7573320
21 September 2022
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7564107
5 January 2022
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7385179
3 October 2021
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7333545
18 November 2020
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7098059
2 October 2020
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7069971
14 January 2020
Drydock Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6889738
12 September 2019
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6816050
20 April 2019
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6671123
7 June 2018
Initial Certification · DAPI Audit
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6436763
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 October 2025
Resolved
Each ring life buoy on a vessel must:(1) Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150; The two main deck ring buoys were missing the required "Q" spec. Replace with in-kind required equipment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2025
Resolved 12 November 2025
Resolution: Vessel replaced ring buoys. All SAT.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 9 October 2025
Resolved
Complete but simple instructions for the operation of a fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and stop valve control and in the space where the extinguishing agent cylinders are stored. If the storage cylinders are separate from the protected space, the instructions must also include a schematic diagram of the system and instructions detailing alternate methods of releasing the extinguishing agent should the local manual release or stop valve controls fail to operate. Each control valve to a distribution line must be marked to indicate the space served. CO2 activation stations were missing operation instructions. Mount instructions by all operating stations.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2025
Resolved 12 November 2025
Resolution: Crew installed new signs. All SAT.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 October 2025
Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked as follows:(1) Spaces storing carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. VENTILATE THE AREA BEFORE ENTERING. A HIGH CONCENTRATION CAN OCCUR IN THIS AREA AND CAN CAUSE SUFFOCATION.” Tank room is missing this verbiage.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2025
Resolved 12 November 2025
Resolution: Crew installed a new sign. All SAT.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 October 2025
Resolved
An alarm for a fixed gas fire extinguishing system must be clearly and conspicuously marked “WHEN ALARM SOUNDS-VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED”. Engine room is missing this verbiage.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2025
Resolved 12 November 2025
Resolution: Crew installed a new sign. All SAT.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 October 2025
Resolved
Spanner wrenches must be provided where a 40 millimeter (1.5 inch) diameter fire hose is required. Both fire hose stations are missing spanner wrenches. Provide correct wrenches at stations.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2025
Resolved 12 November 2025
Resolution: Crew provided wrenches at fire stations. All SAT
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 9 October 2025
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Label upper deck with appropriate number of passengers.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2025
Resolved 12 November 2025
Resolution: Crew provided 2nd deck signage. All SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 9 October 2025
Resolved
Watertight doors and watertight hatches must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR—KEEP CLOSED” or “WATERTIGHT HATCH—KEEP CLOSED”. Label all deck hatches.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2025
Resolved 12 November 2025
Resolution: Crew labeled all hatches. All SAT.
04 - Emergency Systems › N/A - No Subsystem › Safe areas
Issued 9 October 2025
Resolved
A crew accommodation space and a work space must be of sufficient size, adequate construction, and with suitable equipment to provide for the safe operation of the vessel and the protection and accommodation of the crew in a manner practicable for the size, facilities, service, route, speed, and modes of operation of the vessel. Vessel is missing required signage in crew only locations by the pilot house. Install sign on line stating "CREW ONLY" on port and stbd side of pilot house.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2025
Resolved 12 November 2025
Resolution: Crew installed new sign. All SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 October 2025
Resolved
(1) Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date.(i) You must contact the cognizant OCMI to schedule an inspection at a time and place which he or she approves. No written application is required. Vessel went past due on annual inspection. Contact local OCMI to schedule annual inspection.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 9 October 2025
Resolved 12 November 2025
Resolution: All SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 September 2024
Resolved
The Certificate of Inspection must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. Vessel has misplaced the original COI and has a copy posted showing only page 1. Once new COI is received, the original must be kept on board and the copy posted must show both pages.
46 CFR 176.302
Code 16 c
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 October 2024
Resolution: Posted and new COI issued.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 23 September 2024
Resolved
A vessel must comply with the applicable requirements for any radio and EPIRB installation including the requirements for a station license and installation certificates to be issued by the FCC as set forth in 47 CFR part 80. Vessel has misplaced FCC license, all other FCC documents were present and had current dates. Contact FCC inspector and get a reprint of the license.
46 CFR 184.502
Code 16 c
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 October 2024
Resolution: Station lic on vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 September 2024
Resolved
When a marine employer determines that a casualty or incident is likely to become an SMI defined by 4.03-2, alcohol testing of each individual must be conducted within 2 hours of the SMI. Vessel owner has an unapproved BAC testing device. Replace with an approved DOT testing device or testing strips.
46 CFR 4.06-3
Code 16 c
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 October 2024
Resolution: Testing strips in office.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 September 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 October 2024
Resolution: EAP posted in office.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 September 2024
Resolved
Fire Hoses: On a vessel of more than 65' each hose must be lined commercial hose that conforms to UL 19 or hose that is listed and labeled by an independent laboratory recognized by the Commandant as being equivalent in performance, by 50' in length x 1.5" diameter and have fittings of brass or other suitable material. Vessel currently has unlined hoses that are not approved. Replace to the satisfaction of the attending MI.
46 CFR 181.320 (b)
Code 16 c
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 October 2024
Resolution: Approved lined hoses installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 September 2024
Resolved
A bilge pipe piercing the collision bulkhead must be fitted with a screw down valve located on the forward side of the collision bulkhead and operable from the weather deck or if it is readily accessible under service conditions a screw down valve without a reach rod may be fitted to the bilge line on the after side of the collision bulkhead. In additions bilge piping must be 1.5" nominal pipe size. Collision bulkhead valve currently has a ball valve with flexible hose piping connection. Replace with a screw down gate valve and all hard pipe connection to main line.
46 CFR 182.510 (d)
Code 50 c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2024
Resolved 12 December 2024
Resolution: New piping and valve installed.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 23 September 2024
Resolved
A vessel must comply with the applicable requirements for any radio and EPIRB installation including the requirements for a station license and installation certificates to be issued by the FCC as set forth in 47 CFR part 80. Vessels EPIRB HRU was expired. Replaced while MI on board.
46 CFR 184.502
Code 10 c
Action required: 10 - Deficiency Rectified
Resolved 23 September 2024
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 June 2023
Resolved
Suitable fire hoses shall be in place as required. Both fire hoses were found with leaks.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 June 2023
Resolved 28 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 28 June 2023
Resolved
A float free EPIRB shall be provided for vessels operating beyond three miles from shore. The HRU was found expired.
Action required: 10 - Deficiency Rectified
Due 28 June 2023
Resolved 28 June 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 June 2023
Resolved
Vessels shall be provided with FCC certificates for the route and installed equipment. Bridge to Bridge and the Safety Radio Certificates were found expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2023
Resolved 13 July 2023
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 September 2022
Resolved
The minimum capacity of the fire pump must be 50 gallons per minute at a pressure of 60 PSI. Fire pump gauge would not read pressure above 40 PSI. Demonstrate that the fire pump can maintain 60 PSI to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2022
Resolved 7 October 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 September 2022
Resolved
Each fire hose must conform to UL 19. Two firehoses were found leaking excessively and damaged beyond repair. Replace fire hoses in kind to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 September 2022
Resolved 21 September 2022
Resolution: Vessel provided 2 new approved fire hoses.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 September 2022
Resolved
Rotating machinery must be properly protected by a cover, guard or rail. The port and stbd shafts are exposed and create a hazard to personnel. Rotating components on the fire pump were also exposed. Install adequate machinery guards to prevent personnel from coming into contact with rotating machinery to the satisfaction of the attending Marine Inspector.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2022
Resolved 7 October 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 September 2022
Resolved
Exhaust gas must not leak from the piping or any connections. 4 exhaust leaks were found in the engine room with unapproved temporary repairs. Properly repair or replace exhaust piping to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2022
Resolved 7 October 2022
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 21 September 2022
Resolved
Fire hazards to minimized. Buckets of combustible oil were found under the port and stbd M/E’s. Remove oil from the buckets and dispose of properly to the satisfaction of the attending Marine Inspector.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2022
Resolved 7 October 2022
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 21 September 2022
Resolved
Each item of survival craft equipment must be of good quality for the purpose it is intended to serve. Two life floats were discolored with inadequate retro-reflective tape. Restore or replace life floats so that they are orange in color and restore or replace retro-reflective tape in kind to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2022
Resolved 7 October 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 September 2022
Resolved
A vessel must carry a first aid kit under approval series 160.041 or with equivalent contents. The first aid kit did not meet the requirements of 160.041. Provide appropriate first aid kit.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 5 October 2022
Resolved 21 September 2022
Resolution: Operator provided correct first aid kit.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 21 September 2022
Resolved
A vessel must carry adequate up-to-date US Coast Pilot, CG Light List, Tide Tables. All publications were inaccessible due to computer failure. Prove that vessel can access appropriate publications aboard vessel to the satisfaction of the attending Marine Inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2022
Resolved 7 October 2022
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 October 2021
Resolved
The pump outlet must be fitted with a pressure gauge. Prove proper operation of fire pump pressure gauge. Renew dripping seal on fire pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2021
Resolved 18 November 2021
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 3 October 2021
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Prove proper operation of the visual indicator for the high level water alarm in the lazarette.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2021
Resolved 18 November 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 October 2020
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First Aid Kit contained expired Medications.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2020
Resolved 18 November 2020
Resolution: Vessel obtained new CG approved first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 October 2020
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places. No lifejacket placard was posted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2020
Resolved 18 November 2020
Resolution: Placard posted in passenger accommodation space.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 October 2020
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions. Emergency Instructions were not mounted on board vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2020
Resolved 18 November 2020
Resolution: Emergency instructions posted at the operating station on the bridge.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 2 October 2020
Resolved
Ring life buoys shall be of first class workmanship and free from any defects materially affecting their appearance or serviceability. All three ring life buoys were found to be significantly weather and faded to nearly white on one side.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2020
Resolved 18 November 2020
Resolution: Ring buoys were replaced with approved type.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 12 September 2019
Resolved
Install dampers for forward engine room ventilation.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 September 2019
Resolved 17 September 2019
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 12 September 2019
Resolved
Prove proper operation of the PA system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 September 2019
Resolved 17 September 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 September 2019
Resolved
Post COI and Stability Letter.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2019
Resolved 17 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 September 2019
Resolved
Properly label child PFD storage locker.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2019
Resolved 17 September 2019
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 September 2019
Resolved
Provide first aid kit meeting requirments in 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 September 2019
Resolved 17 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 12 September 2019
Resolved
Establish EPIRB testing log.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 September 2019
Resolved 17 September 2019