Records from 1994 to 2026. Most recent: inspection, 2 April 2026.
Documentation record
Registered dimensions (L × B × D)55.7 ft × 22.0 ft × 9.1 ft
Registered tonnagegross 93 / net 74
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTERREBONNE SHIPBUILDERS · HOUMA, LA, UNITED STATES · built 1975
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 May 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it93 - Simplified, Gross Ton
74 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 40
2 April 2026
MTSA Verification · Vessel Attendance · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8341020
27 March 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8100726
10 April 2024
COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7893218
6 June 2023
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7704686
8 April 2023
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7720948
3 May 2022
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7443746
30 June 2021
Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7240629
1 July 2020
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6992643
28 May 2019
Deficiency Check · Initial Certification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6696323
27 March 2017
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6112957
5 January 2017
Industry Initiated Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6066786
19 February 2013
Industry Initiated Exam · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4535354
2 August 2012
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 4399959
17 June 2012
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4375337
10 July 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4078839
20 September 2010
Marine Casualty Follow Up
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3853579
19 September 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3987100
18 September 2010
Marine Casualty Follow Up
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3853546
18 September 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3987158
11 August 2010
Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3846157
29 April 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3464750
15 October 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3346489
19 April 2008
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3194456
19 April 2008
Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3204609
6 May 2007
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2924287
6 May 2007
Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2940046
31 July 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2842417
20 April 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2629659
4 March 2006
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2608454
25 July 2005
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2439572
1 July 2004
MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2117834
9 January 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1982308
24 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1989593
17 July 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 170025
20 June 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 55231
13 January 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 411821
1 October 1996
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 396023
3 April 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 66975
18 November 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 188096
4 September 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 371137
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 6 June 2023
Resolved
Alarm setpoints must be tested twice every five years, with no more than 3 years elapsing between tests. Alarm setpoints have not been tested since 2019. Ensure alarm set points are tested and ensure record of tests is kept with vessel records.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2023
Resolved 12 June 2023
Resolution: Set points tested.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 June 2023
Resolved
Each towing vessel must have a reliable means to provide notification of high bilge levels. High bilge level alarm was missing from forward hold. Install high bilge level alarm.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2023
Resolved 12 June 2023
Resolution: High water alarm installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 3 May 2022
Resolved
Main engine lubricating oil pressure must be able to be monitored at the machinery location. Pressure gauge for the starboard main engine was inoperable. 46 CFR 143.230(c)(1).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2022
Resolved 4 May 2022
Resolution: Received photo evidence of newly installed pressure gauge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 May 2022
Resolved
There must be an installed or portable bilge pump for emergency dewatering. Forward void space on vessel has no means for emergency dewatering. 46 CFR 143.275.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2022
Resolved 4 May 2022
Resolution: Received photo evidence of portable bilge pump in forward void space.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 30 June 2021
Resolved
A Certificate of Documentation becomes invalid immediately when the ownership of the vessel changes in whole or in part. Ownership of vessel has changed. Ensure receipt of new COD prior to operating vessel.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 July 2021
Resolution: Received new COD
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 June 2021
Resolved
Remote fuel shutoff valves must be located in the fuel piping directly outside the fuel supply tank. Existing fuel shutoff valve is too far from the fuel tanks. During next drydock, reconfigure remote fuel shutoff valves to be directly outside the fuel tanks.
Action required: 705 - Other - as specified
Due 30 June 2024
Resolved 3 May 2024
Resolution: During dry dock period, it was determined that the existing remote fuel shut off valve was satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 30 June 2021
Resolved
Main engines must be equipped with RPM gauges at the machinery location. No tachometers were installed in the engine room. Install tachometers in the engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2021
Resolved 30 July 2021
Resolution: Tachometers installed on both main engines.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 June 2021
Resolved
Electrical systems must minimize fire and shock hazards. Wiring for clothes dryer was found in disrepair. Repair wiring.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2021
Resolved 30 July 2021
Resolution: Wring repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 June 2021
Resolved
All pressure vessels must have the MAWP indicated by a stamp, nameplate, or other means visible to the crew. Starboard receiver was not marked. Mark receiver with MAWP.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2021
Resolved 30 July 2021
Resolution: MAWP marked on receiver.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 June 2021
Resolved
The frame or support of any semi-portable fire extinguisher fitted with wheels must be secured to prevent it from rolling in heavy sea conditions. Semi-portable extinguisher was not secured to deck. Ensure extinguisher is secured to prevent it from rolling.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2021
Resolved 30 July 2021
Resolution: 160-B extinguisher secured to superstructure.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 June 2021
Resolved
Each life buoy with a floating electrical light must have a lanyard of at 3-6 feet in length securing the water light around the body of the lifebuoy. Lanyard was not attached around the body of the lifebuoy. Properly attach lanyard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2021
Resolved 30 July 2021
Resolution: Lanyard attached properly.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 30 June 2021
Resolved
Vessels in maritime service must be licensed by the FCC. Ensure new station license is attained prior to operating vessel.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 July 2021
Resolution: Received new FCC Station License.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 June 2021
Resolved
All marine employers must submit drug testing program data to Commandant CG-INV (USCG Headquarters) by March 15th every year. Submit drug testing data from previous year.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2021
Resolved 15 October 2021
Resolution: Report submitted