WEEKS 189

WEEKS 189 is a 2016 industrial vessel. The Coast Guard has recorded 9 inspections since 2017, most recently in April 2026, along with 13 deficiencies.

Records from 2017 to 2026. Most recent: inspection, 27 April 2026.

Built
2016
Last inspected
27 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDM7095
1380292
Flag
UNITED STATES
Maury page id
psix-1380292

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspections, by type

…with no type recorded1
Years with a record 7 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)144.0 ft × 50.0 ft × 10.0 ft
Registered tonnagegross 539 / net 161
ITC dimensions (L × B × D)144.0 ft × 50.0 ft × 10.0 ft
ITC tonnagegross 539 / net 161
BuilderC & C MARINE & REPAIR LLC · BELLE CHASSE, LA, UNITED STATES · built 2016
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 12 August 2025 · expires 30 September 2026
Service, as the file records itIndustrial Vessel
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it345 - Dead Weight, Gross Ton
345 - Displacement, Gross Ton
539 - Convention (Subpart B), Gross Ton
161 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

TERRY FONTENOT Towing Vessel · MISLE 135988 · 5 February 2023 · activity 7686892CENAC 113 Tank Barge · MISLE 1307411 · 5 February 2023 · activity 7686892DB AVALON Industrial Vessel · MISLE 1711219 · 5 February 2023 · activity 7686892

Inspection history · 9

27 April 2026 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8350010
11 March 2025 Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8092020
22 February 2024 Internal Structural Exam · Deficiency Check · Annual Inspection · Drydock Exam · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7868970
5 February 2023 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7686892
12 January 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7620666
12 August 2022 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7531792
26 July 2021 COI Inspection · Deadweight Survey · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7268664
17 June 2021 Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7227843
3 March 2017 Administrative Inspection · Internal Structural Exam · Welding Related Inspections Qualification Testing
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6167802

Deficiency record · 13

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 April 2026 Resolved
If your vessel's Certificate of Inspection is renewed less often than annually, the marine inspector must check the settings of the safety or relief valves on all pressure vessels, except cargo tanks, twice every 5 years. No more than 3 years may elapse between any check and its immediate predecessor. Vessel rep did not have proof of testing for relief valve on air receiver in generator space.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2026
Resolution: MI received report from vessel rep attesting to testing of pressure relief valves. See documents.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 March 2025 Resolved
The fire main system must be operated and the pressure checked. There is a hole in the fire main between the first overboard flange and the first elbow before the pressure gage.
Action required: 705 - Other - as specified
Resolved 7 April 2025
Resolution: Fire main repaired, pressure test sat.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 March 2025 Resolved
There shall be at least two means of escape where the crew is normally employed. The switchboard room fwd exit door is obstructed from fully opening, hitting a patch in the deck. 46 CFR 91.10-5(a)
Action required: 705 - Other - as specified
Resolved 7 April 2025
Resolution: Deck repaired, door opens unobstructed.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 22 February 2024 Resolved
Every crewmember with emergency duties assigned on the muster list must be familiar with their assigned duties. During the fire drill in the machinery space (generator room), crew forgot to close ventilation and isolate power before entering the space. Additionally, during man overboard drill, crewmembers were unfamiliar with the rescue process of a person that has fallen in the water. Marine inspector had to prop one of the crewmembers to throw the life ring while waiting for the rescue boat to be on site. Company shall incorporate and establish comprehensive procedures to train all crewmembers, on board the barge and with a position on the station bill, on how to respond to a fire, man overboard, or any other emergency addressed on the vessel’s station bill. Vessel shall provide a copy of such procedures to the Coast Guard along with a copy of the training records for the different scenarios with the member’s trained. 46 CFR 199.180
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2024
Resolved 8 May 2024
Resolution: Vessel provided evidence of drills
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 22 February 2024 Resolved
Except as provided in §§ 80.177 and 80.179, operation of transmitters of any ship station must be performed by a person holding a commercial radio operator license or permit of the class required below. The operator is responsible for the proper operation of the station. None of the crewmembers on board the barge had a radio operators license. None of the crewmembers on board the vessel held a radio operators license. 47 CFR 80.155
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2024
Resolved 13 June 2024
Resolution: Received documentation attesting for operators training.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 February 2024 Resolved
Electric installations on vessels must ensure protection of passengers, crew, other persons, and the vessel from electrical hazards. Vessel’s lighting breaker panel by VFD room was missing blank breaker covers on the empty slots thus exposing the bus bar. Vessel shall install breaker covers on the missing slots. 46 CFR 199.180(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2024
Resolved 26 March 2024
Resolution: Received pictures confirming repair.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 22 February 2024 Resolved
The operator or agent of each vessel must verify to his or her satisfaction that the PIC of any transfer of fuel oil requiring a Declaration of Inspection— (1) On each inspected vessel required by 46 CFR chapter I to have an officer aboard, and on each uninspected vessel, either: (i) Holds a valid merchant mariner credential issued under 46 CFR chapter I, subchapter B, with an endorsement as master, mate, pilot, engineer, or operator aboard that vessel, or holds a valid merchant mariner credential endorsed as Tankerman-PIC; or (ii) Carries a letter satisfying the requirements of § 155.715 and designating him or her as a PIC, unless equivalent evidence is immediately available aboard the vessel or at his or her place of employment. None of the crewmembers on board the vessel was able to provide a valid merchant marine credential with a Tankerman-PIC endorsement. Additionally, vessel was not able to provide a letter designating a specific member from the crew on board. Vessel shall always have a crewmember licensed or designated as a tankerman PIC by the company when running its machinery equipment. 33 CFR 155.710(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2024
Resolved 8 May 2024
Resolution: Vessel provided evidence of PIC training program
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 February 2024 Resolved
There must be ground detection for each: ship's service power system; lighting system; and power or lighting distribution system that is isolated from the ship's service power and lighting system by transformers, motor generator sets, or other devices. Lighting breaker panel by Variable Frequency Drive (VFD) room does not have a ground detection system installed. Install a ground detection system for the aforementioned panel. 46CFR111.05-21(b)(c)(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2024
Resolved 26 March 2024
Resolution: Received pictures confirming repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 22 February 2024 Resolved
Fuel oil service, fire, cargo and fuel oil transfer and boiler feed pumps must be provided with a pressure gauge on the discharge side of the pump. Fuel pump next to fuel day tank did not have a pressure gauge indicating the discharge pressure. Install pressure gauge on the discharge side of the fuel pump. 46 CFR 56.50-10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2024
Resolved 26 March 2024
Resolution: Received pictures confirming such.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 January 2023 Resolved
The installation of all systems of an electrical engineering or interior communication nature,..., shall be in accordance with the requirements of Subchapter J of this chapter. Systems of this type include the following: Ship's service generating systems Ship's service power distribution systems Ship's lighting systems Emergency lighting and power systems Electric lifeboat winch systems Fire detecting and alarm systems Sound powered telephone and voice tube systems Navigation lights systems Daylight signaling lights Miscellaneous machinery alarms and controls General alarm systems The vessel could not produce documentation verifying that plan review as required by 46 CFR 96.05-1 had been conducted by the Marine Safety Center(MSC). The vessel shall contact MSC and submit all applicable plans and information required by 46 CFR 110.25-1 within 90 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 June 2023
Resolved 6 December 2023
Resolution: Plan review documents are uploaded in MISLE and indicate that plan review has been conducted.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 7 January 2022 Resolved
47 CFR 80.80 Radio must be able to start and discontinue operation at the ship radio operating station; Radio inoperable, must be in working condition.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 February 2022
Resolved 7 January 2022
Resolution: Vessel rep sent a video of the radio in operating condition.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 January 2022 Resolved
46 CFR 95.50-10 Paint locker must have one 40-B type extinguisher outside of the space; Paint locker missing a fire extinguisher, must be implemented at this location.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 February 2022
Resolved 7 January 2022
Resolution: Vessel added a 40-B type fire extinguisher next to the paint locker.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 January 2022 Resolved
46 CFR 199.45 Lifesaving appliances to be in proper condition including associated equipment; Life jacket stowage station did not have a donning placard; must add placard at this location.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 February 2022
Resolved 7 January 2022
Resolution: Vessel rep added placard next to donning station.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.