MAURY USCG vessel records Sign in
← All vessels

MATE

MATE is a 2011 freight ship. The Coast Guard has recorded 20 inspections since 2016, most recently in February 2026, along with 8 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 19 February 2026.

Built
2011
Last inspected
19 February 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9644990 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1382191
Flag
LIBERIA
—
Maury page id
psix-1382191

Inspections, by type

…with no type recorded9
Years with a record 11 calendar years (2016–2026)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it42814 - Simplified, Gross Ton
42814 - Convention (Subpart B), Gross Ton
51939 - Dead Weight, Ton
16553 - Simplified, Net Ton
16553 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

RESPONSE Towing Vessel · MISLE 576747 · 18 January 2024 · activity 7892690ARTEMIS Towing Vessel · MISLE 1760450 · 18 January 2024 · activity 7892690

Inspection history · 20

19 February 2026 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8312384
7 July 2025 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8168806
18 January 2024 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7892690
22 August 2023 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7774694
4 June 2022 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7467604
25 May 2022 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7458442
23 December 2021 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7371867
18 May 2021 PSC B · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7199542
3 June 2020 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6968311
31 May 2019 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6693220
2 February 2019 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6619029
24 May 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6420428
4 April 2018 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6385639
10 November 2017 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6305892
7 May 2017 Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6140789
6 May 2017 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6141590
4 May 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6138307
1 May 2017 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6136797
10 May 2016 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5873726
7 April 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5849016

Deficiency record · 8

07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 18 May 2021 Resolved
FIRE PROTECTION SYSTEMS AND FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE MAINTAINED READY FOR USE. PSCO OBSERVED 01 BROKEN DAMPER IN FIRE CONTROL ROOM. MULTIPLE FIRE DAMPERS IN E/R WERE TIED OFF AND HUNG NOT READY FOR USE. 74SOLAS(09) II-II/ 14.1.1.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 19 May 2021
Resolved 19 May 2021
Resolution: 01 Code 17 deficiency for M/V MATE, regarding fire dampers, after receiving a satisfactory Flag State Inspection. Nothing further is needed at this time.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 4 June 2020 Resolved
Whenever a defect is doscovered, either of which affects the safety of the ship or the efficiency or completeness of equipment other than life-saving appliances, the master or owner of the ship shal report at the earliest opportunity to the Administration, the nominated surveyor or recognized organization responsible for issuing the relevant certificate. If the ship is in a port of another Contracting Government, the master or owner shal also report immediately to the appropriate port State authorities and the nominated surveyor or recognized organization shall ascertain that such a report has been made. No notifications to the U.S. Coast Guard, local agent, or Administration were made regarding the low suction sea chest outlet valve defect prior to arrival. It was determined that the sea chest valve is not holding properly, likely due to some debris between the valve seat and valve flap. The valve is still in service. All other valves and the system as a whole operates as intended.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2020
Resolved 6 June 2020
Resolution: Provided class survey. Condition of class imposed, required to permanently fix valve CSV04 at next scheduled docking survey, subject to the examination at the periodical survey.
Engineering › Freshwater System (jacketwater cooling) › Pump
Issued 24 May 2018 Resolved
The machinery, boilers, and other pressure vessels associated piping systems and fittings shall be a design and construction adequate for the service for which they are intended and shall be so installed. M/E Jacket cooling pump domestic 3-way valve is actively leaking and being drained via flex hose, flag dispensation letter to be issued for transit to Long Beach, CA. Additionally, Cooling fresh water condenser is spraying water.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 25 May 2018
Resolved 27 May 2018
Resolution: The 3-way valve has been removed and the packing of the stem shaft has been replaced. The valve is no longer leaking. Additionally, the cooling fresh water condenser leaks has been corrected by removing the flanged elbow. New thread seal was administered.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 24 May 2018 Resolved
Oil filtering equipment shall be of a design approved by administration and will ensure any oil mixture discharged does not exceeed 15 ppm. Monitering equipment does not display proper date or time and crew is not able to print or display stored data. PSCO reccomends the issuance of a new calibration certificate.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 25 May 2018
Resolved 27 May 2018
Resolution: The 15PPM dispaly unit hs been adjusted by the electrician on board according to the instrcution manual and now the date and the time are properly displayed.
Engineering › Bilge Water Management System › Pump
Issued 24 May 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform within the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The daily bilge pump has been replaced with diaphragm pump fed with a flex hose from general supply compressed air system.
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Due 25 May 2018
Resolved 27 May 2018
Resolution: Air line to the diaphragm bilge pump has been hard-piped. Current arrangement has be verified and approved.
Navigation › Collision/Grounding Avoidance › Radar
Issued 7 May 2017 Resolved
All ships of 3000 GT and upwards shall have a 3GHz radar, or where considered appropriate by the Administration, a second 9 GHz radar which are functionally independent of those referred to in paragraph 2.2.3. 74 SOLAS (14 CONS.) V/19.2.7.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2017
Resolution: Scanner unit and MIC assembly and installed new MIC/IF board assembly. Also video cable was removed and replaced with new one. Unit tested and is in good working order.
Navigation › Collision/Grounding Avoidance › Radar
Issued 4 May 2017 Resolved
1530 - All ships of 300 GT and upwards shall have a 3GHz Radar or where consider appropiate by the adminstration a second 9GHz radar which are functionally independent of those referred to in paragrapg 2.3.2.
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Due 4 May 2017
Resolved 9 May 2017
Resolution: Scanner unit and MIC assembly and installed new MIC/IF board assembly. Also video cable was removed and replaced with new one. Unit tested and is in good working order.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 7 April 2016 Resolved
2510: The Vessel owner or operator must ensure that they maintain one english language copy of the VRP and copy of the Coast Guard approval letter, on board vessel. Vessel does not have a vessel response plan onboard.33CFR155.5030 (g)(1) 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 May 2016

Ownership record