Records from 2018 to 2025. Most recent: inspection, 15 December 2025.
Documentation record
Registered dimensions (L × B × D)75.8 ft × 34.0 ft × 10.3 ft
Registered tonnagegross 354 / net 106
ITC dimensions (L × B × D)75.8 ft × 34.0 ft × 10.3 ft
ITC tonnagegross 354 / net 106
BuilderSTEINER CONSTRUCTION COMPANY INC · BAYOU LA BATRE, AL, UNITED STATES · built 2016
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portJEFFERSONVILLE, IN
Trade endorsementsCoastwise, charter
DocumentationValid · issued 13 May 2026 · expires 30 June 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it354 - Convention (Subpart B), Gross Ton
106 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
15 December 2025
TPO Audit
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8283352
30 October 2024
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8031861
12 May 2024
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7938989
24 January 2024
Administrative Inspection · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7853731
10 December 2023
Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7836990
9 December 2023
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7840065
8 December 2023
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7837998
20 January 2023
Deficiency Check · Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7624729
15 September 2022
Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7559777
14 September 2022
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7566277
4 May 2022
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 7444064
1 April 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7423107
14 May 2021
TPO Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7196995
3 June 2019
Type not recorded
No type recorded · Station Sabine · USCG Heartland District (CGD-H) · Activity 6703333
16 May 2019
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6685382
17 January 2019
Initial Certification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6637075
6 April 2018
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6387980
6 April 2018
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6389057
21 February 2018
Industry Initiated Exam · MTSA Verification · Administration
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6358633
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 December 2023
Resolved
Machinery and electrical systems must be maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Vessel's starboard z-drive has an oil leak. through a seal on the keel of the vessel. Vessel must submit a transit plan for review prior to getting underway. Once the transit plan is reviewed the vessel will be allowed one time transit in accordance with accepted transit plan to shipyard to affect repairs.
In accordance with CVC Policy Letter 17-10, the above deficiencies may be cleared by the operating company's TPO. TPO must submit a report to the cognizant OCMI within 72 hours of clearing the deficiencies.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 December 2023
Resolved 15 December 2023
Resolution: TPO provided technician report and cleared vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 September 2022
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Vessels port engine experienced a casualty. Identify and repair port engine and associated Z-drive and provide objective evidence in accordance with your TSMS.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 29 September 2022
Resolved 17 September 2022
Resolution: Received objective evidence of repair and sat ops test.