Records from 2016 to 2026. Most recent: inspection, 2 April 2026.
Inspection history · 33
2 April 2026
PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8340397
22 September 2025
PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8238659
16 March 2025
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8094465
23 August 2024
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7985315
28 June 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7944259
14 February 2024
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7865437
14 August 2023
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7767839
7 August 2023
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7762081
26 July 2023
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7750694
1 July 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7727796
30 May 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7700108
18 May 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7691146
11 January 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7620031
23 October 2022
PSC B · Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7580844
5 April 2022
PSC B · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7424730
4 October 2021
MARPOL Annex VI Survey · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7324725
24 March 2021
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7162364
23 September 2020
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7062810
13 September 2020
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7057053
19 June 2020
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6992388
28 February 2020
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6917373
11 February 2020
Deficiency Check · MARPOL Annex I Examination · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6906756
16 July 2019
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6751604
14 January 2019
Deficiency Check · Administrative Inspection · PI Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6609978
4 May 2018
ISPS II Exam · Deficiency Check · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6404889
28 December 2017
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6329731
23 December 2017
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6328277
23 October 2017
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6292889
19 October 2017
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6290997
18 April 2017
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6123683
1 March 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6097012
24 October 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6028227
24 April 2016
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5861030
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 23 August 2024
Resolved
Efficient guardrails or bulwarks shall be fitted on all exposed parts of the freeboard and superstructure decks.
PSCOs observed multiple sections of the deck guardrails broken.
ICLL 1966, Reg 25.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 September 2024
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 27 October 2022
Resolved
Every ship of 400 gross tonnage and above... shall be provided with an oil record book part 1. The oil record book shall be in the form specified in appendix III to this ANNEX.
PSCO's obsereved in the oil record book 02 missed weekly soundings and bunkering operations not recorded correctly.
MARPOL 73/78
Annex I/17.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2022
Resolved 9 November 2022
Resolution: Agent submitted evidence of correction and training with engineers.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 23 September 2020
Resolved
The angular position of the rudder shall: be recognizable in the steering gear compartment. While conducting steering test, PSCOs noticed a difference of 3-6 degrees between steering room and bridge rudder angle indicators.
74 SOLAS (2004 Cons) II-1/29.11.2
Action required: 10 - Deficiency Rectified
Resolved 24 September 2020
Resolution: SECMIA received "confirmation letter" from Flag that the deficiency was corrected. PSCOs attended the vessel, observed a satisfactory steering test and verified accurate rudder angle indicator between steering room and bridge.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 September 2020
Resolved
... Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gastight... Door leading to switch room maintains a hole due to missing bolt in the latch.
74 SOLAS (1997 Cons) II-2/47.1
Action required: 10 - Deficiency Rectified
Resolved 24 September 2020
Resolution: SECMIA received "confirmation letter" from Flag that the deficiency was corrected. PSCOs attended the vessel and verified the "A" class fire door no longer has a hole.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 23 September 2020
Resolved
Satisfactory means shall be provided for the protection of the crew in getting to and from... all other parts used in the necessary work of the sip. The hatch leading to the CO2 room located in the forecastle has a broken hinge due to wastage.
ICLL 66, Reg25(4)
Action required: 10 - Deficiency Rectified
Resolved 24 September 2020
Resolution: SECMIA received "confirmation letter" from Flag that the deficiency was corrected. PSCOs attended the vessel and verified hinge was fixed and hatch operating as intended.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo Securing Manual
Issued 23 September 2020
Resolved
Cargo... stowed and secured... in accordance with the Cargo Securing Manual approved by the Administration. The Cargo Securing Manual does not list the current inventory and maintenance procedures for the D-rings used for securing cargo.
74 SOLAS (2014 Cons) VII/5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2020
Resolved 22 October 2020
Resolution: PSCOs reviewed the documentation provided by the vessel including an updated Cargo Securing Manual, its approval, and Flag attestation to the correction of the deficiency issued.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 11 February 2020
Resolved
Oil filtering equipment referred to in paragraph 1 of this regulations shall be of a design approved by the Administration and shall be such as will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15 ppm. Vessel's OWS 3-way valve has been replaced with a fabricated valve not meeting manufacture specifications. MARPOL (17 Cons) Annex I/Reg14.6 17ac
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2020
Resolution: Vessel’s OWS 3-way valve was submitted for maintenance, re-installed and tested satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 February 2020
Resolved
The main steering gear and rudder stock shall be capable of putting the rudder over from 35 degrees on one side to 35 degrees on the other side. PSCO was not able to test steering gear due to on going hydraulic ram maintenance. SOLAS74(04 Cons)II-1/Reg.29.3.2 17c
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2020
Resolution: Steering gear was tested in the presence of PSCOs and found satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 11 February 2020
Resolved
All ships of 300 gross tonnage and upwards in addition to meeting the requirements of paragraph 2.2 be fitted with an echo-sounding device, or other electronic means, to measure and display the available depth of water. Echo-depth sounder is not displaying lower read-out. SOLAS74(14 Cons)V/Reg. 19.2.3.1 17bc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2020
Resolution: Echo depth sounder head unit was replaced in-kind and tested satisfactory.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 11 February 2020
Resolved
The company should establish procedures...that any non-conformity is reported, with its possible cause, if known. Vessel's echo-depth sounder has not been operated since December 07, 2019. Vessel has been completing check list forms (SMS-L-50-07) and (SMS-L-50-05) indicating proper operation of depth sounder with no non conformities reported. SOLAS74(14 Cons) IX/Reg.3.1 / ISM Code 10.2.2 17bc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2020
Resolution: Additional training was provided to vessel’s crew on operating depth sounder and to report all non conformities.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 17 January 2019
Resolved
Every fuel oil pipe...which would allow oil escape from storage shall be fitted with cock or valve capable of being closed outside the space. PSCO observed air leaking from distribution piping once air source secured indicating an air leak. Pressure relief valve was painted over and appeared inoperable. 74 SOLAS ('97) II-2/Reg 15.2.5
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2019
Resolution: Quick closing valve air system piping inspected and leaks eliminated. PRV was renewed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 January 2019
Resolved
Clear information shall be displayed on each unit indicating alarm about spaces covered. PSCO observed the alarm panel in ECR indicating machinery alarm instead of fire when testing smoke alarm. 74 SOLAS (97 Cons) II-2/Reg 13.1.7
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2019
Resolution: Engine room alarm signals were repaired and verified by CPU services.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 17 January 2019
Resolved
Simple operating instructions with block diagram showing procedures for remote steering gear system shall be on navigation bridge. PSCO observed no diagram on bridge for emergency steering. 74 SOLAS (14 cons) CH V/Reg 26.3.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 January 2019
Resolved 17 January 2019
Resolution: Emergency steering gear instructions and block diagram posted on the navigation bridge.
Operations/Management › Ballast Water Managment › Ballast Exchange
Issued 4 May 2018
Resolved
The Master, Owner, Operator, Agent or person in charge of a vessel equiped with ballast tanks that operate in the water of the United States must employ one of the following ballast water management methods of 33 CFR 151.2025. Vessel Filled Ballast Water Tanks from outside the EEZ and Discharged within the EEZ.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 4 May 2018
Resolved 10 May 2018
Resolution: PSCO verified corrective action by Non-IACS and Flag State.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 4 May 2018
Resolved
The Company and the Ship shall Comply with the Requirements of the International Safety Manangement Code. The Company Should ensure that all Personnel involved in the company's Safety Management System have an adequate understanding of relevant rules , regulations, codes and guidelines. The Master and Chief Mate are unfamiliar with the ballast water management Regulation in regards to the Ballast Water Exchange. 74 SOLAS / ISM CODE 6.4
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 4 May 2018
Resolved 10 May 2018
Resolution: PSCO verified corrective action by Non-IACS and Flag State.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 4 May 2018
Resolved
Oil Filtering equipment referred to this regulation shall ensure that any oily mixture discharge into the sea after passing through the system has an oil content not exceeding 15 ppm. Vessel oily water seperator is inoperable.
MARPOL Annex 1 Reg 146
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 4 May 2018
Resolved 10 May 2018
Resolution: PSCO verified corrective action by Non-IACS and Flag State. OWS was satifactorily tested by PSCO.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 October 2017
Resolved
Every ship which does not carry a doctor shall be provided with an approved medicine chest with readily understandable instructions. Multiple medicines have expired. ILO147/PWSA 33USC1223(b)1
Due 30 December 2017
Resolved 28 December 2017
Resolution: Received class survey report attesting to replacement of expired medication.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 23 October 2017
Resolved
Vessels which have an approved Vessel Response Plan for Non-Tank shall conduct quarterly Qualified Individual notification exercises. No Qualified Individual notification exercises have been conducted for the last year. 33CFR 155.5060(a)(2)
Due 23 November 2017
Resolved 23 December 2017
Resolution: PSC officers checked records and quarterly QI notification exercises were completed satisfactory
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 24 October 2016
Resolved
01 - 1581 - All ships of 500GT and upwards shall have rudder indictaor to determine and display rudder angle. Main rudder angle indicator on bridge is displaying a 06 degree deviation compared to follow up steering mode. Rudder angle indicator on bridge wings are not working. SOLAS74 (14 Cons.) Ch.V/Reg.19.2.5.4
Action required: 705 - Other - as specified
Resolved 27 October 2016
Resolution: Recvd flag state report attesting to repairs. Witnessed a satisfactory RAI test.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 April 2016
Resolved
0650: Lifebuoys shall be provided with self-igniting lights. Port side, aft lifebuoy's light was found inoperable. 74SOLAS(97)III/7.1.3 10c
Action required: 705 - Other - as specified
Resolved 24 April 2016
Fire Fighting › International Shore Connection › Washers
Issued 24 April 2016
Resolved
0720: International Shore Connection shall be kept on board with a gasket, four bolts, and eight washers. Shore connection was found with only four washers. 74SOLAS(97)II-2/19.4 10c
Action required: 705 - Other - as specified
Resolved 24 April 2016
Construction/Loadline › Markings › Load Line Mark
Issued 24 April 2016
Resolved
1220: Load line: Ring, lines, and letters shall be painted in contrasting colours to the respective hull paint colour. Starboard deck line was same color as the hull. ICLL 66/88 Reg.8 10c
Action required: 705 - Other - as specified
Resolved 24 April 2016