Records from 1996 to 2026. Most recent: inspection, 18 August 2026.
Inspection history · 31
18 August 2026
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8467092
15 October 2025
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8253332
10 September 2025
Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8240899
25 June 2025
Administrative Inspection · Drydock Extension · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8167050
25 June 2025
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8167158
21 August 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7971931
12 July 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7739568
12 May 2023
Administrative Inspection · Damage Survey · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7687051
1 March 2023
Examination of Repairs · In-Service Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7644293
21 July 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7512494
23 July 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7265745
25 April 2021
In-Service Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7182590
19 June 2020
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6992388
29 May 2020
Initial Certification · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6963333
26 August 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6528259
30 July 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6503125
2 August 2016
DAPI Audit
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6034014
25 July 2016
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5952554
19 January 2016
Deficiency Check · Industry Initiated Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5799602
2 August 2012
Industry Initiated Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4398780
1 August 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2732666
21 April 2006
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2657061
30 December 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2266503
19 May 2004
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 2081772
19 February 2004
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2010117
25 November 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1954309
7 February 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1747252
28 May 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1632916
2 December 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 101146
28 September 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 81376
23 February 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 388290
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 September 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel experienced port engine failure.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 January 2026
Resolution: vessel completed satisfactory sea trials with new engine installed.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 30 June 2025
Resolved
The following vessels must have on board a properly installed, operational Coast Guard type-approved AIS Class A device: Vessels AIS not working properly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2025
Resolved 14 July 2025
Resolution: AIS replaced and working.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 June 2025
Resolved
The Bridge-to-Bridge Act and the regulations of this part apply to the following vessels in the navigable waters of the United States: Every towing vessel of 7.8 meters (26 feet) or over in length, measured from end to end over the deck excluding sheer, while navigating. Vessel does not have Bridge-to-Bridge certificate. 47CFR80.1001
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2025
Resolved 2 September 2025
Resolution: Operator obtained required cert.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 30 June 2025
Resolved
Garbage Placards applies to—(1) A manned U.S. ship that is 26 feet or more in length. Vessel does not a have garbage placard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2025
Resolved 14 July 2025
Resolution: Placards purchashed and installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 June 2025
Resolved
Each lifebuoy on a towing vessel must:(1) Be approved under approval series 160.050 or 160.150;Grab line. The grab line shall be 3/8-inch diameter polyethylene, polypropylene, or other suitable buoyant type synthetic material having a minimum breaking strength of 1,350 pounds. Grab lines on both lifebuoys are wasted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2025
Resolved 14 July 2025
Resolution: Wasted grab lines replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 June 2025
Resolved
Each lifebuoy on a towing vessel must: (2) Be capable of being rapidly cast loose; (3) Not be permanently secured to the vessel in any way. Lifeline for both lifebuoys was zip tied to hand rails preventing the lifebuoy from being rapidly cast loose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2025
Resolved 14 July 2025
Resolution: Lifelines properly installed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 21 August 2024
Resolved
The officer in charge of a navigational watch must conduct a navigation assessment for the intended route and operations prior to getting underway. The navigation assessment must incorporate the requirements of pilothouse resource management of § 140.640, assess operational risks, and anticipate and manage workload demands. Vessel is not conducting navigation assessment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 9 September 2024
Resolution: Developed and utilizing Navigation Assessment
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 21 August 2024
Resolved
The owner or managing operator must implement procedures to identify and mitigate health and safety hazards. Vessel must obtain vessel-specific health and safety manual.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 25 September 2024
Resolution: Made correction to H&S Manual
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 21 August 2024
Resolved
For vessels other than those covered in paragraphs (b) and (c) of this section, the name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. Vessel does not have the name of the vessel on the port and starboard side of the bow.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 9 September 2024
Resolution: Vessel name properly marks on vessel bow
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 21 August 2024
Resolved
The emergency duties and duty stations required by this section must be posted at each operating station and in a conspicuous location in a space commonly visited by crewmembers. If posting is impractical, such as in an open boat, they may be kept onboard in a location read-
ily available to the crew. Crew duties weren't posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 9 September 2024
Resolution: Posted crew duties in messdeck and pilot house
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 August 2024
Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces. This may be accomplished by an installed detection system, or by using individual battery-operated detectors meeting UL 217 (incorporated by reference, see § 136.112 of this subchapter). Detection systems or individual detectors must be kept operational at all times when the crew is onboard the towing vessel. Vessel does not have smoke detection in berthing space on second deck.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 9 September 2024
Resolution: All smoke detectors replaced with new.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 21 August 2024
Resolved
The following systems must be equipped with gauges at the machinery location: (1) Main engine lubricating oil pressure and main engine RPM and (3) Auxiliary generator engine lubricating oil pressure and auxiliary generator engine RPM. Main engines and auxiliary generators do
not have RPM gauges installed in the machinery space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 9 September 2024
Resolution: Gauges installed on all MDE and SSDG
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 August 2024
Resolved
All pressure vessels must have the MAWP indicated by a stamp, nameplate, or other means visible to the crew. Vessels pressure vessel does not have a nameplate with MAWP visible to the crew.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 9 September 2024
Resolution: Nameplate installed as required
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 August 2024
Resolved
Pressure vessels must be externally examined annually. Relief valves must be tested in accordance with § 143.245. Vessel has not tested pressure vessel relief valve as required.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 9 September 2024
Resolution: Pressure relief valves replaced with new.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 August 2024
Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. Alarm setpoints shall be tested twice every 5 years, with no more than 3 years elapsing since last test. Twice every 5 years, with no more than 3 years elapsing since last test. Vessel has not tested required alarm set points in the required time frame.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 9 September 2024
Resolution: Alarm set points tested. Faulty sensors replaced with new.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 August 2024
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following: (a) All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Both main diesel engines fuel racor filters have drain valve leaking on bottom with no cap to prevent fuel leak.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 9 September 2024
Resolution: Caps installed on fuel filter drains to prevent leaking.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 21 August 2024
Resolved
The owner or managing operator must implement procedures to identify and mitigate health and safety hazards, including but not limited to: (13) Sanitation. Sewage was found leaking at MSD overboard pump.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 9 September 2024
Resolution: Leak repaired
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 21 August 2024
Resolved
When operating a vessel on a body of water where the discharge of treated or untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3 or 140.4, the operator must secure each Type I or Type II device in a manner which prevents discharge of
treated or untreated sewage. Valve for MDS overboard
discharge was found in the open position with no
locking device installed within the river.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 9 September 2024
Resolution: Valve closed
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage comminuting and disinfecting system
Issued 21 August 2024
Resolved
No person may operate any vessel equipped with installed toilet facilities unless it is equipped with:(1) An operable Type II or III device that has a label on it under § 159.16 or that is certified under § 159.12 or § 159.12. MSD is missing its label.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 9 September 2024
Resolution: Label installed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 21 August 2024
Resolved
Each watertight door and watertight hatch must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR—KEEP CLOSED” or “WATERTIGHT HATCH—KEEP CLOSED”. All water tight hatches on main deck are missing required labels.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 9 September 2024
Resolution: Hatches properly labeled.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 August 2024
Resolved
Sufficient lighting suitable for the marine environment must be provided within crew working and living areas. Engine room and steering pump space has broken light fixture covers and are using zip ties to fasten together.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 9 September 2024
Resolution: Replacement lights installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 August 2024
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Aft breaker panel in engine room missing blanks for spots with no breaker installed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 9 September 2024
Resolution: Blanks installed in breaker panel
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 August 2024
Resolved
Electrical equipment must be marked with its respective current and voltage ratings. Distribution panels in engine room missing required markings.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 9 September 2024
Resolution: Markings installed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 August 2024
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Aft electrical distribution panel has wooden door installed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 9 September 2024
Resolution: Door replaced with manufacters replacement.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 August 2024
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Dead end wire found in port side engine room with wire nut installed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 9 September 2024
Resolution: Dead end wires properly capped.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 21 August 2024
Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. The tests required by this section must be recorded in accordance with part 140 of this subchapter. Vessel has not conducted a test of the alarm set points and emergency fuel shutoff valve tests.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 9 September 2024
Resolution: Test completed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 August 2024
Resolved
Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use. Flammable liquids are being stored in engine room and bosun room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 9 September 2024
Resolution: Flammable liquids removed from vessel
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 21 August 2024
Resolved
46 CFR 144.605 Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. Vessel has no means to close ventilation openings to machinery spaces
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 9 September 2024
Resolution: Ventilation dampners instaled
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 21 August 2024
Resolved
Participation in drills. Drills must take place onboard the towing vessel as if there were an actual emergency. They must include: (1) Participation by all crew members. Monthly fire drills are not being conducted with full crew complement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 9 September 2024
Resolution: Fire drills conducted by all operators and crew.
01 - Certificates & Documentation › 012 - Crew Certificates › Training and qualification MLC - Personnel safety training
Issued 21 August 2024
Resolved
The master must ensure that each crewmember who has not participated in the drills required by paragraph (a) of this section and received the instruction required by that paragraph (a) receives a safety orientation within 24 hours of reporting for duty. The safety orientation must cover the particular contingencies listed in paragraph (a) of this section. Vessel is not documenting new hire orientation properly in accordance with their procedure.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 9 September 2024
Resolution: Safety orientation completed by all crew.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 12 July 2023
Resolved
The owner or managing operator of a towing vessel must establish procedures to address fall overboard prevention and recovery of persons in the water, including, but not limited to: (1) Personal protective equipment; (2) Safely working on the tow; (3) Safety while line handling; (4) Safely moving between the vessel and a tow, pier, structure, or other vessel; and (5) Use of retrieval equipment.
Establish fall overboard prevention/recovery procedures and ensure all crew are familiar.
46 CFR 140.425(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2024
Resolved 25 September 2024
Resolution: Made correction to H&S Manual
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 May 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel reported loss of propulsion (port main engine) during towing evolution.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2023
Resolution: Air control valve replaced in kind. Operational testing of engine and clutch sytem conducted. Test Sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 July 2021
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Electrical equipment and electrical cables must be suitably protected from wet and corrosive environments. Electrical components that pose an electrical hazard must be in an enclosure. Installed port and starboard bilge pumps in engine room have their power supplied from the ship's diesel generators via extension cords. Provide electrical proposal to repair same in accordance with proper marine practices to install marine grade wiring, circuit breakers, connectors and junction boxes for each pump.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 August 2021
Resolution: Vessel corrected electrical concerns and provide pictures of repairs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 April 2021
Resolved
The area of operation for each towing vessel and any necessary operational limits are determined by the cognizant OCMI and recorded on the vessel's COI....limitations imposed or extensions granted are described by reference to bodies of waters, geographical points, distances from land, depths of channel, seasonal limitations, and similar factors. Vessel was identified as operating 14.9 NM offshore out of compliance with their Rivers route on their certificate of inspection.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 30 May 2021
Resolved 4 May 2021
Resolution: CG Inspectors attended vessel for descoped satisfactory safety inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 April 2021
Resolved
Deficiency added for the purposes of S&R actions against the credentialed mariner for violation of law/ regulation.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 26 May 2021
Resolved 26 May 2021
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 June 2020
Resolved
All fire detection systems must be inspected or tested at least once every 12 months. Fire detetion system onboard must be inspected by a qualified servicing organization. 46CFR142.240(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2020
Resolved 14 July 2020
Resolution: Service report provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 June 2020
Resolved
Electrical systems must minimize shock hazards. Unused slots in bridge breaker panel must be blanked. 46CFR143.400(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2020
Resolved 15 July 2020
Resolution: Proof of blanks installed provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 June 2020
Resolved
Individual circuit breakers on distribution panels must be labeled with a description of the loads they serve. Legend must be placed on circuit breaker panel in pilothouse. 46CFR143.400(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2020
Resolved 14 July 2020
Resolution: Panels were properly labeled.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 30 June 2020
Resolved
Essential systems or equipment must be regularly tested and examined. Vessel must perform applicable tests in Table 143.245(b) and log entries in the towing vessel record (TVR).
46CFR143.245(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2020
Resolved 14 July 2020
Resolution: Vessel provided log book and entries.
Accommodation/Occupational Safety
Issued 23 February 1996
Resolved
MANUFACTURER LABLE WAS PAINTED OVER MAKING IT UNABLE TO READ MANUFACTURER INFORMATION.
Condition: Unknown
Due 23 March 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past