Inspection history · 35
11 August 2026
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8462303
16 March 2026
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8326671
29 July 2025
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8190736
16 October 2024
COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8012334
6 August 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7975224
22 July 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7964211
16 July 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7961390
9 August 2023
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7771130
6 December 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7613357
21 July 2022
Deficiency Check · Administrative Inspection · Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7512486
18 July 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7510134
5 October 2021
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7327011
3 August 2021
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7275847
8 August 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7027118
15 May 2019
Deficiency Check · Initial Certification · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6684589
26 August 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6528259
30 July 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6503125
14 December 2016
Uninspected Other
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6057549
24 February 2015
Deficiency Check · Industry Initiated Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5081442
19 January 2012
DAPI Audit · Industry Initiated Exam · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4226874
4 January 2010
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3658918
19 November 2008
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 3366705
29 May 2008
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3221527
22 May 2008
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3220447
5 September 2006
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2769252
16 August 2006
Administrative Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2749717
22 February 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2590019
2 June 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 76471
28 June 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 114645
7 January 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 20507
14 August 1996
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 764382
13 July 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 180356
10 July 1996
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 197002
12 April 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 366026
4 June 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 309378
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 July 2025
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Electrical wire nut connections not within a junction box are not secured to prevent loosening.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2025
Resolved 21 August 2025
Resolution: Electrical connections properly spliced and placed in J-box
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 July 2025
Resolved
Individuals, who are not crewmembers, on board a towing vessel must receive a safety orientation prior to getting underway or as soon as practicable thereafter, to include:(a) The location, operation, and use of lifesaving equipment;(b) Emergency procedures;(c) Methods to notify crewmembers in the event of an emergency; and(d) Prevention of falls overboard. Non crew orientation has not been established or recorded.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2025
Resolved 21 August 2025
Resolution: Check list added to H&S program
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 July 2025
Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. The tests required by this section must be recorded in accordance with part 140 of this subchapter. General alarm not tested and recorded weekly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2025
Resolved 21 August 2025
Resolution: General alarm testing added to weekly check sheet
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 July 2025
Resolved
A towing vessel of at least 26 feet, but less than 79 feet, in length must carry a minimum of two lifebuoys located on opposite sides of the vessel where personnel are normally present. Lifebuoys must be at least 610 millimeters (24 inches) in diameter. Lifebuoys are located on aft second deck not located where personnel are normally present.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2025
Resolved 21 August 2025
Resolution: Life rings moved so they are next to pilot house
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 October 2024
Resolved
No person may intentionally drain oil or hazardous material into the bilge of a towing vessel from any source. Crew was observed stripping fuel tanks into the engine room bilge. Remove fuel from bilges and conduct training with crews to ensure oils and hazardous materials are not discharged into the bilges.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2024
Resolved 30 October 2024
Resolution: Cleaned fuel from bilges and conducted training to not discharge fuel into bilges.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 October 2024
Resolved
Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use. Flammable liquids found in storage room with ignition sources.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2024
Resolved 30 October 2024
Resolution: Removed flammable liquids
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 October 2024
Resolved
The following systems must be equipped with gauges at the machinery location:
(2) Main engine cooling water temperature;
(3) Auxiliary generator engine lubricating oil pressure and auxiliary generator engine RPM;
Port main engine water temperature gauge not working and port auxiliary generator tachometer not properly working.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2024
Resolved 30 October 2024
Resolution: All gauges replaced and working properly
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 October 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Flame shield on starboard Racor fuel filter missing. Install to original condition.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2024
Resolved 30 October 2024
Resolution: Flame bowl installed on racor filter
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 16 October 2024
Resolved
Each escape hatch and emergency exit used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”. Sign for escape hatch missing.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2024
Resolved 30 October 2024
Resolution: Escape properly labeled
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 October 2024
Resolved
Each lifebuoy on a towing vessel must be marked in block capital letters with the name of the vessel. Vessel's name is worn off of life buoy on port side of pilot house.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2024
Resolved 30 October 2024
Resolution: Life ring remarked
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2024
Resolved
The connections of flexible cable plugs and socket outlets must be designed to prevent unintended separation. Permanently installed extension cord installed on pilot house and going through deck on starboard side.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2024
Resolved 30 October 2024
Resolution: Extension cord removed
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 October 2024
Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces. Birthing space was not equipped with smoke detector. CORRECTED ON THE SPOT
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 16 November 2024
Resolved 16 October 2024
Resolution: Installed new smoke detector in birthing
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 October 2024
Resolved
Each lifejacket must have a lifejacket light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the lifejacket. Life jacket light not working. CORRECTED ON THE SPOT
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 October 2024
Resolved 16 October 2024
Resolution: Replaced light with new
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 July 2024
Resolved
A towing vessel may not be operated without having onboard a valid COI issued by the Coast Guard as required by 136.202.
46 CFR 176.105(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2026
Resolution: Vessel has a valid COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 July 2022
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Starboard side propeller is damaged. Repair or replace in kind. Port side shaft indicates wastage. Repair or replace in kind. Visible cracking noted via pictures from operator on starboard shaft strut housing. Provide report of non-destructive testing (i.e. dye penetrant, ultrasound, etc.) to confirm extent of potential internal damage.Provide technician's service report once all repairs are completed. All repairs to be conducted with regards to acceptable marine practices. Vessel may transit to local dry-dock facility only for repairs approximately several hundred yards from vessel's current homeport.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 30 November 2022
Resolved 7 November 2022
Resolution: Starboard side propeller replaced. Port side shaft replaced. Starboard shaft strut housing replaced. All Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 2 September 2021
Resolved
Life float has multiple areas of deterioration but is still serviceable. Repair as original to en sure equipment is properly maintained.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 September 2021
Resolution: Life float replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 September 2021
Resolved
Life float does not have required floating electric waterlight. Provide waterlight in accordance with 46 CFR 161.010 approval series.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 2 September 2021
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 September 2021
Resolved
Fixed fire pump must be capable of delivering water...at 50psi and a flow rate of at least 80gpm. Pressure guage installed at pump indicates 30psi. Replace guage.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 September 2021
Resolution: Vessel provided proof of proper pressure.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 September 2021
Resolved
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 September 2021
Resolution: Pick-ups now operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 15 May 2019
Resolved
A skiff must be of suitable size for all persons on board the towing vessel. Vessel's current COI requires 04 persons to be provided with survival craft accommodations. Current skiff is only suitable to carry 02 persons. Vessel is restricted to carry 02 persons only.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 7 August 2019
Resolution: Vessel purchased and installed CG approved life float.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 14 December 2016
Resolved
Port side main engine piping for water cooling is missing lagging or protection from heat by touch. Provide means to protect crew from water cooling line.
Action required: 705 - Other - as specified
Resolved 12 January 2017
Engineering › Fuel Oil Service System › Valve, Control
Issued 14 December 2016
Resolved
Accessibility to emergency fuel shutoff is restricted by the access latches to the containment. Provide quick access to emergency shutoff valve.
Action required: 705 - Other - as specified
Resolved 12 January 2017
Communications › Alarms/Indicators › General Alarm
Issued 14 December 2016
Resolved
Visibility restricted to the general alarm in the engine room. General alarm also held by one bolt. Unrestrict the visibility to general alarm and make permenant.
Action required: 705 - Other - as specified
Resolved 12 January 2017
Communications › Alarms/Indicators › General Alarm
Issued 16 August 2006
Resolved
Provide proof of required general alarm sign in engine room
Action required: 705 - Other - as specified
Due 11 September 2006
Resolved 5 September 2006
Resolution: Provided proof of GE sign for engine room.
Engineering
Issued 4 June 1986
Resolved
VESSEL DID NOT HAVE A STANDARD DISCHARGE CONNECTION ON BOARD AS REQUIRED BY33CFR155.410(A)(3).
Condition: Unknown
Due 4 June 1986
Resolved 4 June 1986
Lifesaving
Issued 4 June 1986
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 June 1986
Resolved 4 June 1986
Accommodation/Occupational Safety
Issued 4 June 1986
Resolved
VESSEL DID NOT HAVE AN APPROVED MARINE SANITATION DEVICE ON BOARD AS REQUIRED BY 33CFR159.7(B)(2). VESSEL'S INSTALLED TOILETS HAD PIPING THAT DISCHARGED RAW SEWAGE DIRECTLY OVERBOARD.
Condition: Unknown
Due 4 June 1986
Resolved 4 June 1986
Engineering
Issued 4 June 1986
Resolved
VESSEL DID NOT HAVE A FIXED PIPING SYSTEM ON BOARD FOR DISCHARGE OF OILY MIXTURES TO A RECEPTION FACILITY AS REQUIRED BY 33CFR155.410.
Condition: Unknown
Due 4 June 1986
Resolved 4 June 1986
Fire Fighting
Issued 4 June 1986
Resolved
PROVIDE EVIDENCE THAT ALL PORTABLE FIRE EXTINGUISHERS HAVE BEEN PROPERLY SERVICED.
Condition: Unknown
Due 4 June 1986
Resolved 4 June 1986