Inspection history · 85
27 October 2025
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8259606
10 February 2025
Internal Structural Exam · COI Inspection · Cargo Tank Internal · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8078069
16 January 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7862523
20 January 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7626227
26 March 2022
Bulk Liquid Transfer Monitor
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7419044
8 December 2021
Administrative Inspection · DAPI Audit · COI Inspection · MTSA Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7365184
21 January 2021
Annual Inspection · Deficiency Check · Examination of Repairs · Administrative Inspection · MTSA Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7128154
6 January 2021
Deficiency Check · Examination of Repairs · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7120509
6 March 2020
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6925126
19 December 2019
Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6876935
13 December 2018
Deficiency Check · Periodic Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6597444
5 January 2018
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6333399
9 January 2017
COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6068371
28 January 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5814530
14 January 2015
Administrative Inspection · Drydock Exam · Plan Review (Other than "T") · Examination of Repairs · MTSA Verification · Hull Examination · Cargo Tank Internal · Internal Structural Exam · Welding Related Inspections Qualification Testing · Periodic Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5053136
21 January 2014
Cargo Tank Internal · Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4784875
11 January 2012
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4222390
10 March 2010
MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3692374
13 February 2009
Cargo Tank Internal · Annual Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3400829
22 May 2008
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3220447
4 March 2008
Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3155909
11 January 2007
Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2853429
6 April 2006
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2622403
22 February 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2590044
31 January 2005
MTSA Verification · Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2283540
3 January 2005
Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2267906
31 March 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2034716
11 February 2004
Re-Inspection · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2004772
12 March 2003
Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1756408
11 January 2002
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1478002
11 April 2001
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1062568
4 April 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1427995
9 March 2001
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1059738
25 January 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1386680
18 May 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 78615
10 February 1999
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 730032
5 February 1999
Deficiency Check · Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1399045
12 January 1999
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 44322
12 January 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 179243
12 January 1999
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 811272
29 January 1998
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1449001
13 January 1998
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 810269
16 July 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 540111
26 February 1997
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1404311
20 September 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 759331
16 September 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 199737
26 March 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1363560
8 March 1996
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1412935
31 December 1994
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409288
8 March 1994
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1440782
26 January 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 677117
22 January 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 106300
22 January 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 141094
16 December 1993
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1160531
17 November 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1145537
9 March 1993
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1399823
19 May 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 957891
10 March 1992
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1270789
4 September 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 527326
19 September 1990
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 455552
9 August 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 491774
19 March 1990
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1217311
13 February 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 458818
30 November 1989
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1238675
21 November 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 456388
21 April 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 501626
20 January 1989
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 891732
29 March 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 489733
5 March 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 491384
11 January 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1010290
3 December 1987
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1000809
13 October 1987
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1018323
24 March 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1018709
23 February 1987
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 504837
13 November 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1020735
2 September 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 510201
26 March 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 482816
12 December 1985
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 986194
27 November 1985
Permit to Proceed · Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1302979
12 July 1985
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1292885
16 June 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1291968
3 January 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 976682
21 November 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1285394
12 December 1983
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 971838
7 December 1981
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1275341
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 January 2021
Resolved
Any vessel using the navigable waters of the United States or any port or other place subject to the jurisdiction of the United States, including a vessel using an offshore facility subject to the jurisdiction of the United States, except— A vessel that is 300 gross tons or less; or (ii) A non-self-propelled barge that does not carry oil as cargo or fuel and does not carry hazardous substances as cargo.
Vessel is required to have a COFR but cannot verify COFR
online and was unable to verify valid COFR onboard. Proof of valid COFR required.
33 CFR 138.15
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 March 2020
Resolved
A VESSEL BEING PUSHED AHEAD, NOT BEING PART OF A COMPOSITE UNIT, SHALL EXHIBIT AT THE FORWARD END A SPECIAL FLASHING LIGHT. THE VESSEL'S SPECIAL FLASHING LIGHT WAS OBSTRUCTED BY WORKSHACK LOCATED ON THE BOW. LOCATE VESSEL'S SPECIAL LIGHT IN ACCORDANCE WITH RULE 21 OF THE INLAND NAVIGATION RULES. UNTIL SUCH TIME AS THE LIGHT IS PERMANENTLY RELOCATED, THE LIGHT MUST BE TEMPORALLY RELOCATED TO ENSURE PROPER VISIBILITY. (WHEN CLEARING THE REQURIEMENT, ENSURE THE LIGHT MEETS THE THE REQUIRED ARC OF VISIBILITY (180-225 DEGREES)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 April 2020
Resolved 17 March 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 March 2020
Resolved
The owner, master, or person in charge of a tank vessel must ensure that portable and semi-portable extinguishers are inspected and maintained in accordance with NFPA 10. Fire extinguisher located at the bow near the generator did not have a valid six year service collar. Vessel is to have extinguisher serviced.
Action required: 703 - Prior to bunkering operations
Due 26 March 2020
Resolved 13 March 2020
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 12 March 2020
Resolved
Any tank vessel which is equipped with an internal combustion engine driven cargo pump on the weather deck shall be provided with a minimum of one remote manual shutdown station. Wire for emergency shutdown was damaged. Vessel is to replace wire run for emergency generator.
Action required: 705 - Other - as specified
Due 26 March 2020
Resolved 13 March 2020
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 12 March 2020
Resolved
Cargo tanks in which Grade D or E liquids only are to be transported shall be fitted with gooseneck vents and flame screens. 04 goosneck vents had paint on there flame screens. Vessel is to replace flame screens.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 March 2020
Resolved 13 March 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 12 March 2020
Resolved
All watertight opening shall be designed to maintain watertight integrity. Hatch located at the stern was not watertight. Vessel is to make hatch watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2020
Resolved 13 March 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 January 2020
Resolved
Vessels generator had dry rotted fuel lines. Replace all fuel lines on generator.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 January 2020
Resolved 5 March 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 9 January 2020
Resolved
#1 wing tank stbd side hatch cover needs replacement.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2020
Resolved 5 March 2020
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 9 January 2020
Resolved
# 1 wing tank stbd side 4th Frame from the stern had cracked welds on the bottom 2 side shell Longitudinal.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2020
Resolved 5 March 2020
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 9 January 2020
Resolved
# 1 wing tank stbd side between frames 3 and 4 had cracked welds in the side shell longitudinal.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2020
Resolved 5 March 2020
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 9 January 2020
Resolved
# 1 wing tank stbd side aft most longitudinal at the top had a missed weld at the end of the frame
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2020
Resolved 5 March 2020
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 9 January 2020
Resolved
# 1 wing tank stbd side ladder rungs need replacement
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2020
Resolved 5 March 2020
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 9 January 2020
Resolved
# 2 wing tank stbd side has a cracked weld on the deck longitudinal.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2020
Resolved 5 March 2020
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 9 January 2020
Resolved
#2 wing tanks side has a large inset (about 20FT.) long with bent frames and longitudinal.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2020
Resolved 5 March 2020
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 9 January 2020
Resolved
#3 wing tank stbd side 1st from aft, second from the top and bottom most frame has cracked welds.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2020
Resolved 5 March 2020
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 9 January 2020
Resolved
#4 wing tank stbd side deck longitudinal has wasted area with holes identified
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2020
Resolved 5 March 2020
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 9 January 2020
Resolved
#4 wing tank port side aft most vertical frame has cracked weld.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2020
Resolved 5 March 2020
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 19 December 2019
Resolved
FWD void port and stbd side head logs near the side shell has insets and cracked welds.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2020
Resolved 5 March 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 December 2018
Resolved
Support for engine exhaust wasted. Replace to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2019
Resolved 14 December 2018
Resolution: Support for engine exhaust was renewed to the satisfaction of the attending Marine Inspector.
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 9 January 2018
Resolved
No proof of approved COFR
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 February 2018
Resolved 10 January 2018
Resolution: Vessel Provided evidence of Valid COFR
Lifesaving › Lifebuoys › Serviceable
Issued 21 January 2014
Resolved
Ring Buoy seal was cracked and not serviceable, ring buoy was ordered to be replaced.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 January 2014
Resolution: New ring buoy on board
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 6 April 2006
Resolved
Replace #1 and # 4 portside hatch covers.
Condition: Improper/Lack of Maintenance
Due 6 May 2006
Resolved 25 April 2006
Resolution: # 1 and # 4 portside hatch covers replaced as of 25 Apr 06.
Engineering
Issued 11 January 2002
Resolved
Provide pressure gauge on discharge side of pump within view of the operator. LEGACY COMPONENT DESC: Cargo Pump
Action required: 705 - Other - as specified
Due 11 February 2002
Resolved 14 January 2002
Resolution: Installed pressure guage in location were it can be seen by the operator.
Stability › Watertight Integrity
Issued 11 January 2002
Resolved
Replace gasket on #1 port wing tank hatch cover. LEGACY COMPONENT DESC: Hatch cover
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 February 2002
Resolved 14 January 2002
Resolution: Put new gasket in hatch.
Construction/Loadline › Markings
Issued 11 January 2002
Resolved
Provide vessel name on stern. LEGACY COMPONENT DESC: Vessel Name/Home Port
Action required: 705 - Other - as specified
Due 11 February 2002
Resolved 14 January 2002
Resolution: Vessel name has been painted on the stern.
Construction/Loadline
Issued 4 April 2001
Resolved
REPLACE STERN VOID HATCH COVER.
Condition: Unknown
Due 4 April 2001
Resolved 4 April 2001
Deck/Cargo
Issued 4 April 2001
Resolved
PLACE GUARD OVER PULLEYS AND PLACE LAGGING ON ENGINE EXHAUST ON PUMP ENGINE.
Condition: Unknown
Due 4 April 2001
Resolved 4 April 2001
Unknown
Issued 4 April 2001
Resolved
PLACE NAME OF VESSEL ON STERN.
Condition: Unknown
Due 4 April 2001
Resolved 4 April 2001
Deck/Cargo
Issued 4 April 2001
Resolved
HAVE P/V VALVES OPEN FOR INSPECTION.
Condition: Unknown
Due 4 April 2001
Resolved 4 April 2001
Construction/Loadline
Issued 12 January 1999
Resolved
Complete offload of cargo and proceed to BOURG DDX for permanent repairs ofdamage in #3 S wing void and #2 cargo tank expansion trunk, starboard side._x001C_ Vessel not operate until repairs are completed and inspected by USCG.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Engineering
Issued 8 March 1996
Resolved
Secure diesel fuel supply and return lines to/from diesel tank and cargo pump engine.
Condition: Unknown
Due 8 March 1996
Resolved 8 March 1996
Engineering
Issued 17 November 1993
Resolved
MAKE PERMANENT REPAIRS TO DIESEL FUEL LINE FROM DIESEL TANK TO CARGO TRANSFER ENGINE. FUEL LINE HAS LEAK IN SEVERAL PLACES.
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Construction/Loadline
Issued 17 November 1993
Resolved
MAKE PERMANENT REPAIRS TO #2 & #4 STBD VOID HATCH COVERS. AT PRESENT, EACHCOVER IS MISSING "DOGS" WHICH PREVENT PROPER SECURING OF THESE OPENINGS.
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Navigation
Issued 10 March 1992
Resolved
PROVIDE PROOF THAT BARGE NAV LIGHTS AND ELECTRICAL JUNCTION BOX AND WIRING MEET 46 CFR 111.105 FOR HAZARDOUS LOCATIONS.
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Construction/Loadline
Issued 27 November 1985
Resolved
MAKE PERMANENT REPAIRS TO THE DECK KNUCKLE (24" GASH, HORIZONIAL ALONG TOP OF KNUCKLE ON SIDE SHELL) AND SIDE SHELL SETIN ABOUT 10". PERMIT TO PROCEED ISSUED. NO CG-835 WRITTEN.
Condition: Unknown
Due 27 November 1985
Resolved 27 November 1985
Unknown
Issued 3 January 1985
Resolved
PRIOR TO LOADING ANY CARGO POST ON BOARD VALID FMC CERTIFICATE.
Condition: Unknown
Due 3 January 1985
Resolved 3 January 1985