MAURY USCG vessel records Sign in
← All vessels

MISS TAMMY

MISS TAMMY is a 1979 passenger vessel (inspected). The Coast Guard has recorded 87 inspections since 1981, most recently in May 2026, along with 79 deficiencies, 5 operational controls and 3 casualty investigations between 2001 and 2025.

Records from 1981 to 2026. Most recent: inspection, 12 May 2026.

Built
1979
Last inspected
12 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDM9713
Flag
UNITED STATES
368311000
Maury page id
psix-50409

Inspections, by type

…with no type recorded21
Years with a record 40 calendar years (1981–2026)
The 87 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)91.3 ft × 19.6 ft × 2.3 ft
Registered tonnagegross 86 / net 62
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSWIFTSHIPS INC · LAFITTE, LA, UNITED STATES · built 1979
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it86 - Regulatory (Subpart C or D), Gross Ton
62 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM9713MMSI 368311000 · active · compulsorily equipped · granted 7 May 2022, expires 7 May 2032
WDG2944MMSI 368311000 · terminated · compulsorily equipped · granted 9 March 2012, cancelled 6 May 2022
WDF8554MMSI 367496120 · expired · compulsorily equipped · granted 21 June 2011, cancelled 21 August 2021
WDD8655MMSI 369123000 · expired · compulsorily equipped · granted 4 July 2007, cancelled 9 September 2017
WDA5941MMSI 366825880 · cancelled · compulsorily equipped · granted 14 September 2001, cancelled 9 August 2011
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 8

Inspection history · 87

12 May 2026 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8371237
2 December 2025 Examination of Repairs · Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8273334
24 April 2025 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8120183
11 April 2025 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8111658
11 April 2025 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8117702
30 April 2024 Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7903824
4 December 2023 Drydock Exam · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7833496
14 June 2023 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7716660
15 December 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7609762
17 June 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7480386
10 May 2022 DAPI Audit · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7447138
6 May 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7445523
30 November 2021 Hull Examination · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7358783
18 May 2021 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7196172
26 May 2020 Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6958074
19 November 2019 Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6858667
3 June 2019 In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6721381
16 April 2019 Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6663392
16 May 2018 Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6410960
30 November 2017 Drydock Exam · Plan Review "T" Boat · Examination of Repairs · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6315949
4 May 2017 COI Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6137627
20 May 2016 Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5882035
4 December 2015 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5776387
29 September 2015 Internal Structural Exam · Administrative Inspection · Drydock Extension
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5731431
13 August 2015 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5215216
4 August 2014 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4943782
9 February 2012 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4241349
12 October 2010 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3868209
22 July 2009 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3544344
9 December 2008 Administrative Inspection · Re-Inspection · Examination of Repairs · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3376976
25 November 2008 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3369019
25 November 2008 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3369538
21 August 2008 Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3304919
10 December 2007 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3112587
10 December 2007 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3112627
7 December 2007 Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3111494
25 July 2007 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3006768
21 September 2006 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2784071
30 September 2002 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1682016
5 September 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1376743
24 August 2001 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1376744
28 March 2001 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1062055
28 March 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1618838
30 October 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468169
3 September 1999 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1469284
25 May 1999 Examination of Repairs · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1099817
18 May 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 78615
18 May 1999 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1132089
13 May 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468922
29 September 1998 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447903
26 September 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 24266
2 June 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465402
5 December 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1111822
24 September 1997 Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1422910
21 June 1996 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1416330
28 May 1996 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1465864
30 April 1996 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1355777
30 May 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1186497
2 May 1995 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1357138
29 October 1994 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 371928
14 September 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 161474
12 May 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 859234
3 May 1994 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1398058
29 September 1993 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 844930
26 April 1993 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1370587
7 October 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1252036
6 November 1990 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 899974
14 December 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 927374
22 November 1989 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1229684
13 September 1989 Examination of Repairs · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1306380
29 June 1989 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1339875
2 June 1989 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1207754
23 November 1988 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 899167
8 June 1988 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1203624
22 January 1988 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1322889
23 November 1987 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1311151
14 January 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1313441
7 March 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1306754
14 February 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1287342
29 August 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283743
21 February 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278599
9 February 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279657
8 April 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271442
25 February 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972012
12 March 1982 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 966075
27 February 1982 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1272805
23 March 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970104

Deficiency record · 79

03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 12 May 2026 Resolved
A hatch cover must have securing devices; one of the dogs on the stbd aft hatch had broken off and cannot be properly secured. 46 CFR 179.360 (b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2026
Resolved 19 June 2026
Resolution: Broken dog on hatch was replaced and photos sent to MI. In documents tab.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 12 May 2026 Resolved
A vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. The charts available were out of date. 46 CFR 184.420 (a) (1)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2026
Resolved 14 May 2026
Resolution: Vessel rep provided photos of updated charts.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 12 May 2026 Resolved
A hinged watertight bulkhead door must be fitted with … indicator lights at the operating station showing whether the door is open or closed. 01 Watertight door indicator light was extinguished.46 CFR 179.330 (b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2026
Resolved 14 May 2026
Resolution: Vessel rep provided photos of illuminated WT door light.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 12 May 2026 Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. Pin for steering tie rod is undersized, resulting in excessive play.46 CFR 182.610 (a) (1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2026
Resolved 19 June 2026
Resolution: Degraded pins on steering gear were replaced and photos sent to MI. In documents tab.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 April 2025 Resolved
Materials used in piping systems must meet the requirements of this subpart and be otherwise acceptable to the cognizant OCMI. Marine Inspector identified that the starboard fire main supply piping was leaking at an elbow joint following operation of fire pump. Conduct repairs to the satisfaction of the Marine Inspector. 46 CFR 182.700
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2025
Resolved 6 May 2025
Resolution: Operator replaced damaged piping. Inspected repairs with water pressure in the system; all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 April 2025 Resolved
The intent of this part is to insure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. Primary consideration shall be given to the provision of a seaworthy hull, protection against fire, means of escape in case of sudden unexpected casualty, guards and rails in hazardous. Marine Inspector identified that the weld joints were broken for the crew ladder on top of the wheelhouse. Conduct repairs to the satisfaction of the attending Marine Inspector. 46 CFR 177.01-5 (OLD T)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2025
Resolved 20 May 2025
Resolution: Received satisfactory photos of repair.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 24 April 2025 Resolved
with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Marine Inspector identified that the waterlights in each life float and two ring life buoys were expired. Replace expired batteries to the satisfaction of the Marine Inspector. 46 CFR 180.70(d)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2025
Resolved 6 May 2025
Resolution: Operator replaced waterlight batteries; MI verified all expiration dates.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 April 2025 Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Marine Inspector identified multiple combustible waste receptacles on board the vessel. Replace waste receptacles with one's constructed of non-combustible materials to the satisfaction of the Marine Inspector. 46 CFR 177.405(f)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2025
Resolved 20 May 2025
Resolution: Received photo of new waste receptacle.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 30 April 2024 Resolved
The float-free link required by 180.130(a)(1) must be:…of proper strength for the size of the life float or buoyant apparatus as indicated on its identification tag. MI observed the required tag for the weak link missing from the device. Install proper strength weak link so as to cover both lifefloats attached to it and provide evidence of identification tag. 46 CFR 180.137(b)(2)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2024
Resolved 7 May 2024
Resolution: Vessel provided evidence of weaklink tag.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 30 April 2024 Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. MI observed three broken paddles affixed to life floats, additionally 01 water light casing was cracked. 46 CFR 180.175(d)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2024
Resolved 7 May 2024
Resolution: New waterlight properly installed.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 30 April 2024 Resolved
The inspection shall be such as to ensure that the vessel... piping... is in satisfactory condition and fit for the service for which it is intended. MI observed deteriorated metallic piping for air conditioning condenser unit seawater intake at starboard side forward engine room bulkhead. Provide tamper proof means to secure through hull valve on damaged pipe until permanent repairs can be made to the satisfaction of the marine inspector. 46 CFR 176.05-10(a) Old T
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2024
Resolved 7 May 2024
Resolution: Metallic piping flange replaced and welded through bulkhead.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 30 April 2024 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. MI observed 01 life float in poor condition with cracks and deterioration to exterior coating. Prior to carrying more than 22 persons on board, repair or replace damaged life float to the satisfaction of the marine inspector. 46 CFR 180.175(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 27 June 2024
Resolution: Witnessed correct installation of life float to include markings, paddles, and weak link. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 April 2024 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. During functional test of high water alarms no audible alarm sounded at the operating station. 46 CFR 182.530(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 21 May 2024
Resolution: Visual and audible alarm sound at the operating station.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 30 April 2024 Resolved
At each inspection for certification and reinspection the marine inspector shall examine the bilges and other spaces to see that there is no accumulation of oil or other matter which might create a fire hazard. MI observed excessive accumulation of oil in vessel bilges with evidence of oil leaks on all three engines.46 CFR 176.25-50(b) Old T
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 7 May 2024
Resolution: E/R bilges were properly cleaned and dry.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 30 April 2024 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB. MI observed battery for EPIRB onboard expired 4/24. Prior to operating outside of 3nm seas, install EPIRB to the satisfaction of the MI. 46 CFR 180.64
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 8 May 2024
Resolution: Vessel operator provided photgraph of NOAA registration decal on EPIRB.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 April 2024 Resolved
The inspection shall be such as to insure that the vessel, as regards... electrical installations...is in satisfactory condition and fit for the service for which it is intended. MI observed hanging electrical cabling over starboard engine at risk of contacting running machinery. 46 CFR 176.05-10(a) Old T
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 7 May 2024
Resolution: Electrical cable properly supported.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 December 2022 Resolved
Vessel that is operating on a Coastwise or Oceans route must have an interconnected fire detection system in compliance with 46 CFR 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. The vessel is limited to a Limited Coastwise route until the installation of an interconnected fire detection system. 46 CFR 181.405 (c)
Action required: 705 - Other - as specified
Resolved 8 February 2024
Resolution: Verified installation and operation of fire detectors.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 December 2022 Resolved
On a vessel that is operating on a Coastwise or Oceans route, flammable items not otherwise covered by the regulations of this subchapter, such as rechargeable batteries, including lithium ion batteries utilized for commercial purposes, must be handled, stored, and operated in a way that mitigates the risk of hazardous conditions. Vessel operator to provide information regarding the presence of such items onboard the vessel to a MI. 46 CFR 185.364
Action required: 705 - Other - as specified
Resolved 8 February 2024
Resolution: VErified presence and contents of plan.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 June 2022 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel reported loss of propulsion on starboard engine. 46 CFR 182.200 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2022
Resolution: Operator conducted repairs and conducted successful power trials. Engine is operating normally.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 May 2022 Resolved
A vessel to which this subchapter applies may not be operated without having onboard a valid U.S. Coast Guard Certificate of Inspection. Vessel's Certificate of Inspection expired on 04May2022.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 May 2022
Resolution: COI conducted, satisfactory.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 26 May 2020 Resolved
EACH LIGHTING FIXTURE GLOBE, LENS, OR DIFFUSER MUST HAVE A GUARD. MI NOTED A LIGHTING FIXTURE IN AN ACCOMMODATION SPACE DID NOT CONTAIN A GUARD. 46 CFR 183.410(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2020
Resolved 27 May 2020
Resolution: Received photo from operator of replaced light guard above forward bunk.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Equipment (including exemption)
Issued 26 May 2020 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2020
Resolved 18 June 2020
Resolution: Received photo documentation from operator with EPIRB installation verified by technician and checked on the FCC Radio Safety Telephony Certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 26 May 2020 Resolved
LIFE FLOATS AND BUOYANT APPARATUS MUST NOT BE STOWED IN TIERS MORE THAN 4 FEET HIGH. WHEN STOWED IN TIERS, THE SEPARATE UNITS MUST BE KEPT APART BY SPACERS. MI FOUND THAT THE 02 LIFE FLOATS WERE STOWED IN TIERS WITH NO SPACERS. 46 CFR 180.137 (4)(f)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2020
Resolved 26 May 2020
Resolution: VESSEL'S CREW PLACED SPACERS IN BETWEEN TIERS OF LIFE FLOATS. CORRECTED ON THE SPOT.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 26 May 2020 Resolved
EACH PADDLE OF A LIFE FLOAT MUST BE OF AT LEAST 4 FEET IN LENGTH, LASHED TO THE LIFE FLOAT TO WHICH IT BELONGS AND BUOYANT. MI FOUND THAT THE 02 PADDLES WERE LOOSE AND NOT LASHED TO THE LIFE FLOAT. 46 CFR 180.175 (f)(2)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2020
Resolved 26 May 2020
Resolution: VESSEL'S CREW LASHED THE PADDLES TO THE LIFE FLOATS VIA NYLON LINE. CORRECTED ON THE SPOT.
Construction/Loadline › Structures › Door
Issued 20 May 2016 Resolved
Realign engine room watertight door so that it seals. Repair crack on upper left dog when leaving the engine room.
Action required: 705 - Other - as specified
Due 20 June 2016
Resolved 26 May 2016
Resolution: Watertight door repaired and rehung
Engineering › Bilge Water Management System › Pump
Issued 13 August 2015 Resolved
Prove proper operation of two fixed power bilge pumps.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 September 2015
Resolution: New pump installation satisfactory. Pump satisfactorily tested by pumping out galley space, farthest pickup from engine room.
Electrical › Lighting (emergency) › Lighting Branch Circuit
Issued 13 August 2015 Resolved
Prove the vessel has emergency lighting that automatically actuates upon failure of the primary lighting.
Action required: 705 - Other - as specified
Resolved 4 September 2015
Resolution: Lighting satisfactorily tested.
Lifesaving › Lifefloat › Serviceable
Issued 13 August 2015 Resolved
Properly repair the damage to the two identified life floats.
Due 13 September 2015
Resolved 4 September 2015
Resolution: Life Float repaired in accordance with manufacturer instructions.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 13 August 2015 Resolved
Install lagging/insulation of the stbd generator exhaust piping.
Due 20 August 2015
Resolved 9 October 2015
Stability › Watertight Integrity › General
Issued 13 August 2015 Resolved
Provide a new bulb for generator for water tight door idicator light.
Due 20 August 2015
Resolved 4 September 2015
Resolution: Door Indicator light now works properly.
Electrical › Lighting (service) › Lighting Fixture
Issued 13 August 2015 Resolved
Resecure the light in the lazarette to make it permanently mounted.
Due 13 September 2015
Resolved 4 September 2015
Resolution: Light Properly secured
Stability › Weathertight Integrity › General
Issued 13 August 2015 Resolved
Provide devices that properly attach watertight hatches to prevent loss.
Due 20 August 2015
Resolved 4 September 2015
Resolution: Devices now properly attached.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 4 August 2014 Resolved
Provide proof of insulation for the piping leading from the turbo to the manifold
Due 13 August 2014
Resolved 6 August 2014
Resolution: Recieved photograph showing proper insulation of hot piping.
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 9 December 2008 Resolved
Vessel had a 8 inch bell, replace with 12 inch bell
Action required: 705 - Other - as specified
Due 8 June 2009
Resolved 8 June 2009
Resolution: Provided a 12 inch bell
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 December 2008 Resolved
Excessiive dead end wiring under pilot house controls, remove
Action required: 705 - Other - as specified
Due 8 June 2009
Resolved 8 June 2009
Resolution: Resoleved by third party (Electician)
Lifesaving › Work Vest › General
Issued 9 December 2008 Resolved
Rescue harness for rescue platform expired. Replace
Action required: 705 - Other - as specified
Due 8 June 2009
Resolved 8 June 2009
Resolution: Provided a new rescue harness
Lifesaving › Buoyant Apparatus › Readily Accessible
Issued 9 December 2008 Resolved
Provide spacers for Buoyant Apparatus
Action required: 705 - Other - as specified
Due 8 June 2009
Resolved 8 June 2009
Resolution: Provided spacers for Buoyant Apparatus
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 9 December 2008 Resolved
Conduct drills for man overboard and fire. Also include the proper donning f the rescue harness for all crew
Action required: 705 - Other - as specified
Due 8 June 2009
Resolved 8 June 2009
Resolution: Conducted drills for man overboard and fire. Also include the proper donning f the rescue harness for all crew
Personnel › Training › Hull Integrity
Issued 10 December 2007 Resolved
Vessel master and owner/operator failed to notifiy OCMI of repairs needed to vsl and conducted unauthorized repairs.
Action required: 705 - Other - as specified
Due 10 December 2007
Resolved 10 December 2007
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 7 December 2007 Resolved
The vessel lost the center shaft in the Aug/Sept 2007 time frame and began to take on water through the shaft tube.
Action required: 705 - Other - as specified
Resolved 7 December 2007
Resolution: Witnessed sat operation of the center shaft/engine coupling through a sea trial.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Notice of Marine Casualty
Issued 5 December 2007 Resolved
Vessel owner/operators failed to make report of marine casualty following loss of center shaft while underway with passengers.
Action required: 705 - Other - as specified
Resolved 5 December 2007
Operations/Management › Casualty Reporting/Post-Casualty Actions › Filing Written Report of Marine Casualty
Issued 5 December 2007 Resolved
Vessel owner/operators failed to submit CG-2692 within 5 days of casualty.
Action required: 705 - Other - as specified
Resolved 5 December 2007
Construction/Loadline
Issued 18 May 1999 Resolved
PROCEED TO SHIPYARD VIA INLAND WATERS TO COMPLETE PERMANENT REPAIRS TO PORTSIDE SHELL & FRAMINING, IWO ENGINE ROOM FWD BKHD, MAIN DECK IWO PORT SIDE GENERATOR ROOM, BULKWARK & CARGO RAIL.
Condition: Unknown
Due 18 May 1999
Resolved 18 May 1999
Documentation
Issued 28 May 1996 Resolved
Provide FCC Safety Radiotelephony Certificate or third party certificate._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 May 1996
Resolved 28 May 1996
Construction/Loadline
Issued 30 April 1996 Resolved
Replace broken windshield in pilot house in front of steering station.
Condition: Unknown
Due 30 May 1996
Resolved 28 May 1996
Lifesaving
Issued 30 April 1996 Resolved
Remove unauthorized electric heaters from crews berthing._x001C_ _x001C_ _x001C_ Use UL 1025, UL 1096 or UL 1042 heaters I.A.W. 46/111.83-3
Condition: Unknown
Due 7 May 1996
Resolved 28 May 1996
Construction/Loadline
Issued 30 April 1996 Resolved
Replace broken window on port side of house just forward of exit door._x001C_
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Documentation
Issued 30 April 1996 Resolved
Provide FCC radio Safety Telephony Certificate or third party certificate.
Condition: Unknown
Due 30 May 1996
Resolved 28 May 1996
Engineering
Issued 30 April 1996 Resolved
Make available for internal inspection the port air receiver.
Condition: Unknown
Due 14 May 1996
Resolved 28 May 1996
Navigation
Issued 30 April 1996 Resolved
Provide current Coast Pilot [name withheld] and Tide Table publications._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 May 1996
Resolved 28 May 1996
Lifesaving
Issued 30 April 1996 Resolved
Replace three (3) undersized liferings with 24" Ring Buoys.
Condition: Unknown
Due 7 May 1996
Resolved 28 May 1996
Engineering
Issued 30 April 1996 Resolved
Replace both inoperative relief valves for the two air receivers in the engine room.
Condition: Unknown
Due 14 May 1996
Resolved 28 May 1996
Accommodation/Occupational Safety
Issued 30 April 1996 Resolved
Properly route dryer exhaust vent out of space. Also use metal duct and hose.
Condition: Unknown
Due 27 May 1996
Resolved 28 May 1996
Fire Fighting
Issued 30 April 1996 Resolved
Replace fire pump discharge pressure gauge.
Condition: Unknown
Due 14 May 1996
Resolved 28 May 1996
Engineering
Issued 2 May 1995 Resolved
REPLACE ALL PLASTIC PETCOCKS ON RACOR FILTERS WITH STEEL.
Condition: Unknown
Due 2 May 1995
Resolved 2 May 1995
Navigation
Issued 3 May 1994 Resolved
REPAIR STBD. JOCKEY BAR BOLT
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Lifesaving
Issued 3 May 1994 Resolved
RENEW LIFE JACKET LIGHTS ON 10 LIFEJACKETS, VESSEL TO SEGREGATE UNUSABLE JACKETS SO THEY ARE NOT USED. VESSEL IS RESTRICTED TO 44 PASSENGERS UNTIL THIS ITEM IS CORRECTED
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Lifesaving
Issued 3 May 1994 Resolved
RENEW BATTERY IN EPIRB. VESSEL IS RESTRICTED TO 20 MILES OF HARBOR OF SAFE REFUGE, UNTILL THIS ITEM IS CORRECTED.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Engineering
Issued 3 May 1994 Resolved
DOUBLE NUT SELECTOR VALVE ACCUTATOR ON CENTER AND STBD. REDUCTION GEARS
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Electrical
Issued 3 May 1994 Resolved
RENEW MOUNTING BOX FOR STBD DECK FLOODLIGHT.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Electrical
Issued 3 May 1994 Resolved
REPAIR/RENEW MISSING E-LIGHT IN ENGINE ROOM PORT SIDE AFT.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Electrical
Issued 3 May 1994 Resolved
DEMONSTRATE PROPER OPERATION OF BOTH S/S GENERATOR OVERSPEED TRIPS.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Electrical
Issued 3 May 1994 Resolved
REINSTALL WIRING IN STBD. MOST SWITCH BOX ON CENTER MAIN ENGINE.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Engineering
Issued 3 May 1994 Resolved
PROPERLY REPAIR CRACKED ENGINE MOUNT ON CENTER ENGINE PORT SIDE AFT.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Engineering
Issued 3 May 1994 Resolved
PROPERLY BRACKET AND SHORTEN ALL F/O, L/O, AND HYDRAULIC HOSE ON ALL ENGINES AND STEERING.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Fire Fighting
Issued 3 May 1994 Resolved
HAVE ALL FIRE EXTINGUISHERS SERVICED ON BOARD.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Engineering
Issued 3 May 1994 Resolved
INSTALL PYREX GLASS SIGHT TUBE AND GUARDS IN LUBE OIL STORAGE TANK.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Documentation
Issued 3 May 1994 Resolved
PROVIDE ON BOARD WASTE MANAGEMENT PLAN/MARPOL V PLACARDS
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Electrical
Issued 3 May 1994 Resolved
PROPERLY BLANK CIRCUIT PANEL AND FIX HINGES ON DOOR IN GENERATOR ROOM STBD SIDE AFT.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Engineering
Issued 22 November 1989 Resolved
REMOVE PUSH-ON FOSE FITTINGS ON MAIN ENGINE OIL SENTINEL SYSTEMS AND INST. APPROVED FITTINGS.
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Engineering
Issued 22 November 1989 Resolved
INSTALL APPROVED TYPE OF FLEXIBLE HOSE ON MAIN ENGINE TURBOCHARGER OIL SUP.LINES FOR HIGH TEMPERATURE APPLICATION.
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Construction/Loadline
Issued 9 February 1984 Resolved
REPLACE EMERGENCY ESCAPE HATCH OVER ENGINE ROOM STARBOARD SIDE NOT LATER THAN 09MAR84.
Condition: Unknown
Due 9 February 1984
Resolved 9 February 1984
Unknown
Issued 9 February 1984 Resolved
THE FOLLOWING ITEM PERTAINS TO THE M/V C/RAVAGER, O.N. DN611414
Condition: Unknown
Due 9 February 1984
Resolved 9 February 1984
Engineering
Issued 25 February 1983 Resolved
REMOVE OR REPLACE WITH GLASS, THE SIGHT GLASS ON THE LUBE OIL TANK.
Condition: Unknown
Due 25 February 1983
Resolved 25 February 1983
Accommodation/Occupational Safety
Issued 25 February 1983 Resolved
REPLACE PLASTIC STOVE VENT PIPE WITH METAL VENT PIPING.
Condition: Unknown
Due 27 March 1983
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 25 February 1983 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL C/RAVAGER, DN611414.
Condition: Unknown
Due 25 February 1983
Resolved 25 February 1983
Engineering
Issued 25 February 1983 Resolved
FABRICATE AND INSTALL DRIP PANS UNDER ALL ENGINE AND GENERTOR FUEL FILTERS.
Condition: Unknown
Due 25 February 1983
Resolved 25 February 1983
Electrical
Issued 25 February 1983 Resolved
REPAIR/REPLACE LIGHT SWITCH IN RUDDER COMPARTMENT.
Condition: Unknown
Due 25 February 1983
Resolved 25 February 1983
Accommodation/Occupational Safety
Issued 25 February 1983 Resolved
REPAIR ALL VENT COVERS ON MAIN DECK.
Condition: Unknown
Due 25 February 1983
Resolved 25 February 1983

Casualty record · 3

28 March 2001Routine · role: Involved in a Marine Casualty · activity 1618838
25 November 2008Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 3369019
11 April 2025Routine · role: Involved in a Marine Casualty · activity 8117702
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

DELTA TRAVELER (2001–2008). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.