Inspection history · 36
18 June 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8162115
15 April 2025
Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8111703
11 April 2025
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8117702
6 January 2025
Internal Structural Exam · Hull Examination · Deficiency Check · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8059088
6 September 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7998181
6 September 2024
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7998195
12 June 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7933618
21 May 2024
Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7916038
4 April 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7890510
4 April 2024
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7900390
4 January 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7845724
16 October 2023
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7809506
2 May 2023
Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7679386
15 March 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7651677
14 October 2022
Drydock Exam · In-Service Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7577595
7 September 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7553925
7 July 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7500204
7 July 2022
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7500970
17 May 2022
Internal Structural Exam · Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7403911
29 March 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7421726
9 September 2021
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7308738
9 September 2021
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7312021
12 August 2021
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7284788
31 March 2021
Internal Structural Exam · COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7153946
5 February 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6944540
15 August 2019
Examination of Repairs · COI Inspection · Construction Oversight · Drydock Exam · Inclining Experiment · Internal Structural Exam · Plan Review (Other than "T")
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6789922
19 November 2018
Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6565906
12 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6538707
8 September 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6547780
15 August 2017
Internal Structural Exam · COI Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6236794
10 August 2017
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6449899
18 July 2016
Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5945353
2 July 2016
Damage Survey · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5929907
9 February 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5811767
8 February 2016
Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5812092
8 February 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5816181
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 September 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel reported loss of power to stbd main engine on approach to dock. Vessel restricted from carrying passengers until satisfactory tech report is received and sea trials are witnessed by attending Inspector. 46 CFR 119.200
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 September 2024
Resolution: MI witnessed sea trials. Vessel fully operational.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 May 2024
Resolved
If a vessel is not equipped with a single source of power for emergency lighting, it must have individual battery powered lights which:(1) Are automatically actuated upon loss of normal power;(2) Are not readily portable;(3) Are connected to an automatic battery charger; and(4) Have sufficient capacity for a minimum of 2 hours of continuous operation. Vessel was found with a dozen emergency lights that were inoperable. Repair emergency lights to the satisfaction of the attending Marine Inspector.
46 CFR 120.432(b)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2024
Resolution: Attended vessel and verified all E light in working order.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 21 May 2024
Resolved
Each hose must:(1) Be lined commercial firehose that conforms to UL 19 “Standard for Safety for Lined Fire Hose and Hose Assemblies” (incorporated by reference, see 114.600 of this chapter), or hose that is listed and labeled by an independent laboratory recognized by the Commandant as being equivalent in performance; The fire hose attached to station number 1 was found with a pin hole leak at the end of the hose close to the nozzle. Hose was destroyed in front of a Marine Inspector and a new hose was installed and tested to the satisfaction of the Marine Inspector.
46 CFR 118.320(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 21 May 2024
Resolution: Vessel replaced the hose while MI was still on board.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 May 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to: (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Vessel charging station was found with 4 dead end wires that are exposed to passengers. Repair the dead end wires to the satisfaction of the Marine Inspector.
46 CFR 120.200(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2024
Resolved 31 May 2024
Resolution: Dead end wired have been removed
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 May 2024
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: (7) Inspection and testing of smoke and fire detecting systems (including sensors and alarms). Main deck visual fire indicator was improperly installed with tape. Reinstall the visual fire indicator to the satisfaction of the attending Marine Inspector.
46 CFR 115.810(a)(7)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2024
Resolved 31 May 2024
Resolution: Fire indicator properly mounted
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 21 May 2024
Resolved
Vessel was found with no master key control system, control access, use of master keys, and handling protocols. Develop and implement required master key requirements to the satisfaction of the Marine Inspector.
46 USC 3106
CVC Policy Letter 23-06
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2024
Resolved 13 August 2024
Resolution: Operator submitted seniority and senior deck hand list that have access to master keys.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 21 May 2024
Resolved
Drills. The VSO must ensure that at least one security drill is conducted at least every 3 months. Vessel was found with a seven month gap in their security drills in 2023. Log the drills conducted during the annual inspection to the satisfaction of the Marine Inspector.
33 CFR 104.230(b)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2024
Resolved 31 May 2024
Resolution: Completed Security drill
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 21 May 2024
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”, unless such markings are deemed unnecessary by the cognizant [name withheld] forward crew accommodation space was found with an emergency exit that is unmarked. Mark the emergency escape to the satisfaction of the Marine Inspector.
46 CFR 122.606
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2024
Resolved 31 May 2024
Resolution: Emergency escape has been properly labled
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 21 May 2024
Resolved
An internal structural examination conducted in compliance with § 115.600 of this part may be conducted while the vessel is afloat or out of the water and consists of a complete examination of the vessel's main strength members, including the major internal framing, the hull plating, voids, and ballast, cargo, and fuel oil tanks. Heavy pitting was noticed in the starboard wing in the sewage void between the last and second to last transverse frames. Conduct internal hull survey and submit results to the satisfaction of the Marine Inspector prior to credit of next drydock.
46 CFR 115.610(b)
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 February 2025
Resolved 6 January 2025
Resolution: Accepted 3rd party hull exam report.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 May 2024
Resolved
The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable. The fwd crew accommodation space was found with a microwave, air fryer, and spray paint that do not meet the requirements of the constructed fire protection boundaries of a low risk accommodation space. Vessel crew removed items off the ship to meet the requirements of that space.
46 CFR 116.405(a)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 21 May 2024
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 2 May 2023
Resolved
All piping, valves, and fittings shall be in accordance with good marine practice and suitable for the purpose intended. Fire Hose No. 2 valve was seized and inoperable. Vessel's crew lossened valve and MI witnessed operation of valve.
46 CFR 181.15-5(c) "Old T"
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 May 2023
Resolution: Vessel's crew lossened valve and MI witnessed operation of valve.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 May 2023
Resolved
The door must be self-closing with a closure time of not less than 5 seconds and not more than 10 seconds and be capable of closing against a 3.5 list of vessel. Main Deck port side fire door did not close automatically. Hinge was tightened and door closed correcly.
46 CFR 116.435 (c)(7)(i)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 May 2023
Resolution: Hinge was tightened and door closed correcly.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 2 May 2023
Resolved
Have a nozzle that has a 1/2 inch solid stream orifice or a combination nozzle. Nozzles for No. 3,5,6 fire hoses were seized and inoperable. Nozzles were loosened and witnessed operating satisfactorily.
46 CFR 181.15-10 (d)(2) "Old T"
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 May 2023
Resolution: Nozzles were loosended and witnessed operating satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 May 2023
Resolved
Each portable fire extinguisher on a vessel must be of a type approval by the commandant. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant OCMI, but must be not less than the minimum number required by table 118.500(a) of this section. Vessel has an incorrect fire extinguisher at operating station. Correct with propoer fire extinguisher according to the regulations.
46CFR 118.500(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2023
Resolved 26 July 2023
Resolution: Fire extinguisher replaced with 10BC IAW COI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 March 2023
Resolved
A drydock examination conducted in compliance with § 115.600 of this part must be conducted while the vessel is hauled out of the water or placed in a drydock or slipway. During the examination all accessible parts of the vessel's underwater body and...propellers...shall be made available for examination. Submit repair proposal for damaged propeller and make repairs to the satisfaction of the attending marine inspector prior to carriage of passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2023
Resolution: Completed repair. Achieved 80% blue fit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 March 2023
Resolved
The marine inspector may conduct a visual examination and may require nondestructive testing of the propeller shafting whenever the condition of shafting is in question. Vessel hit an object while underway and the condition of the shaft is unknown. Obtain dye penetrate testing on the shaft taper and key way and submit report to the marine inspector. 46 CFR 115.670(b)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2023
Resolution: Test completed; no problems found.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 March 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Leak found on port cardan shaft. Submit engineering report on condition or necessary repairs to the satisfaction of the marine inspector. 46 CFR 119.200(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2023
Resolution: Vessel sent engineering report. See attached document.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 17 May 2022
Resolved
Structures that are located on or above the line of the uppermost complete deck that are open to the weather are exempt from tonnage as open space. The vessel had multiple doors that are not "open to the weather" and were permanently sealed in. The vessel operator to remove these permanent seals for the doors to maintain compliance with vessel's tonnage certificate.
46 CFR 69.117 (d)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2022
Resolved 14 June 2022
Resolution: MI received photos of fixes for the tonnage opening.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 9 September 2021
Resolved
A self-propelled vessel must meet the applicable requirements for main and auxiliary steering apparatus in Subchapter F (marine Engineering) and J (Electrical Engineering) of this chapter. Vessel encountered intermittent steering failure from helm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 September 2021
Resolved 13 September 2021
Resolution: Verified operational test and cleared def.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 31 March 2021
Resolved
A door in a stairwell, stairway, and main verticle zone bulkhead must meet requirements; hold back mechanism for the door must be released upon disruption of power. The doors on upper deck on starboard forward and aft are not releasing upon shutdown of power.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Resolved 31 March 2021
Resolution: Crew was able to get doors to release four times without failure upon inital corrective action.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 19 November 2018
Resolved
46CFR 176.25-35: The marine inspector shall examine and test the main and auxiliary steering apparatus to the extent necessary to determine that its condition is satisfactory and that it is fit for the service intended. Continuous water ingress from port rudder. Vessel must determine cause and repair prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2018
Resolved 25 November 2018
Resolution: USCG Marine Inspector verified via sea trial the proper operation and function of the port and starboard rudder with water ingress resolved by adjusting and addition of shaft packing.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 November 2018
Resolved
46CFR 180.25-15: All life preservers shall be marked with the vessel's name. Numerous life preservers had vessel name missing or too faded to see.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2018
Resolved 17 December 2018
Resolution: Operator submitted photos displaying noted def as corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 November 2018
Resolved
46CFR 180.25-25: ALl life preservers must have retroreflective material attached to its front and back sides. Many life preservers had retroreflective material falling off, or faded and requiring replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2018
Resolved 17 December 2018
Resolution: Operator submitted photos displaying noted def as corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 November 2018
Resolved
46CFR 183.01-15: All electrical installations shall be to the satisfaction of the [name withheld] deck starboard side aft electrical outlet unsecured and hanging from bulkhead with wiring exposed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2018
Resolved 25 November 2018
Resolution: Outlet re-secured to bulkhead and confirmed by CG Marine Inspector on site.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 19 November 2018
Resolved
46CFR 185.30-15: All escape hatches and other emergency exits shall be marked on both sides with 1" letters EMERGENCY EXIT, KEEP CLEAR. Focsle emergency escape hatch not marked on outside.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2018
Resolved 17 December 2018
Resolution: Operator emailed photos of emergency escape hatch marked as per regulation.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 November 2018
Resolved
46CFR 116.435(c)(7)(ii): Hold back hooks are not allowed on horizontal A Class fire doors. If installed, must allow release from a control space or upon distruption of power. Hold back hook installed in self closing A class fire door leading to engine room.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 19 November 2018
Resolved 19 November 2018
Resolution: Hold back hooks removed from door and bulkhead at engine room.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 12 September 2018
Resolved
ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 31 March 2021
Resolution: Verified corrected AIS data this date.
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 15 August 2017
Resolved
Renew IBA launching instructions for the two aft installed IBAs. 46CFR122.518
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 14 September 2017
Resolution: Operator order/received 12 new sets of instructions and will be posting on the entire fleet.
Engineering › Bilge Water Management System › Strainer
Issued 15 August 2017
Resolved
Each bilge suction shall have a strainer with at least three times the area of the bilge pipe. Current arrangement has the strainer too close to the hull for proper operation (void fwd of the E/R). Prove proper operation of the suction line. Old T 46CFR182.25-5
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 29 August 2019
Resolution: New approved bilge piping being installed.
Engineering › Fuel Oil Service System › Filter
Issued 20 July 2016
Resolved
Fuel strainers need to be provided with threaded caps.
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 3 August 2016
Lifesaving › Inflatable Buoyant Apparatus › Float Free
Issued 20 July 2016
Resolved
Replace twisted shackles on 3 of 4 IBAs. Clear painter line of all obstructions. Determine permanent means to remove slack from the system.
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 3 August 2016
Stability › Unintentional Flooding › General
Issued 18 July 2016
Resolved
Port rudder post is leaking water. Packing needs to be serviced.
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 3 August 2016
Construction/Loadline › Structures › Door
Issued 2 July 2016
Resolved
Prove proper operation of 2nd deck gull wing door / hinges, replace broken windows.
Action required: 705 - Other - as specified
Due 2 August 2016
Resolved 2 February 2017
Resolution: Door repaired, windows replaced.
Engineering › Steering Gear System › Rudder
Issued 8 February 2016
Resolved
Renew port side rudder stop and prove proper operation of the vessel's steering gear system to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2016