CAPITOL HORNBLOWER is a 1983 passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 2016, most recently in May 2026, along with 35 deficiencies — 4 with no resolution recorded —, 2 operational controls and 2 casualty investigations between 2008 and 2026.

Records from 2008 to 2026. Most recent: inspection, 19 May 2026.

Built
1983
Last inspected
19 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 19 May 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDN4476
Flag
UNITED STATES
Maury page id
psix-55037

Documentation record

Registered dimensions (L × B × D)76.6 ft × 22.1 ft × 7.4 ft
Registered tonnagegross 76 / net 51
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1983
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSACRAMENTO, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 22 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it76 - Regulatory (Subpart C or D), Gross Ton
51 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 24

19 May 2026 Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8375899
30 March 2026 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8334528
30 March 2026 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8338815
26 January 2026 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8347257
25 February 2025 COI Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8080362
24 April 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7900313
9 January 2024 Drydock Exam · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7846481
28 September 2023 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7800587
17 May 2023 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7691382
9 March 2023 Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7648181
7 February 2023 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7633639
3 November 2022 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7592258
22 September 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7564686
2 June 2022 Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7464243
30 July 2021 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7275240
4 May 2021 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7189310
3 March 2020 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6904583
31 January 2020 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6900535
19 March 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6644659
7 January 2019 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6607662
16 August 2018 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6514240
14 May 2018 Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6414321
29 March 2017 Annual Inspection · Administrative Inspection · Deficiency Check · Plan Review (Other than "T")
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6113456
14 March 2016 Annual Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5832969

Deficiency record · 35

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 May 2026 Resolved
Each life jacket must be marked with Type I retroreflective material approved in accordance with § 164.018 in subchapter Q of this chapter, or other standard specified by the Commandant. Marine Inspector observed 05 child life jackets with unsatisfactory retroreflective material. Operator to replace retroreflective material to the satisfaction of the Marine Inspector. Capacity of vessel to carry children on board to be reduced by 05 until rectified. 46 CFR 122.604 (h)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 June 2026
Resolution: Operator submitted satisfactory photos to clear deficiency for child life jackets.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 19 May 2026 No resolution recorded
The intent of this part is to insure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. Primary consideration shall be given to the provision of a seaworthy hull. Marine Inspector observed significant pitting on interior of hull in forward void. Operator to conduct repairs to the satisfaction of the Marine Inspector prior to next credit dry dock. 46 CFR 177.01-5(a) "Old-T"
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 March 2026 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Vessel had reported experiencing a reduction in propulsion to STBD main engine; provide root cause analysis, effect repairs, and conduct satisfactory sea trial. Vessel is prohibited from carriage of passengers. Allowed one time transit to Pier 19. 46 CFR 119.100
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 May 2026
Resolution: Observed satisfactorily running starboard engine during underway portion of inspection. Operator stated reduction in propulsion was due to faulty ECU. Replaced ECU.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 25 February 2025 No resolution recorded
The intent of this part is to insure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. MI found stress fracture weld cracks in the lazarette. Stress fractures are located on both port and starboard side strut bearing internal support aft frames. Vessel conducted satisfactory NDT dye pen test, cracks will be monitored, conduct repairs prior to next credit dry dock to satisfaction of MI. 46 CFR 177.01-5(a)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 25 February 2025 No resolution recorded
The intent of this part is to insure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. MI found crack in the lazarette, starboard side main diesel engine exhaust support frame. MI will monitor the crack until vessel can conduct repairs prior to next credit dry dock. 46 CFR 177.01-5(a)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 25 February 2025 No resolution recorded
Through hull fittings and shutoff valves shall be metal. MI found plastic overboard discharge located on the port side in the sewage tank void. Conduct repairs prior to next credit dry dock to the satisfaction of the MI. 46 CFR 182.40-1(a)(3)
Condition: Improper Installation
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 25 February 2025 Resolved
The intent of this part is to insure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. MI found pitting in the lazarette. Pitting was located between the second and third transverse frames on both port and starboard side. Clean and descale, identify extent of pitting in identified areas, and provide original plate thickness to the satisfaction of the MI. 46 CFR 177.01-5(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2025
Resolved 21 May 2025
Resolution: Vessel cleaned areas and added protective coating, photos attached to doc tab. Special note was added for these areas to be monitored.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 25 February 2025 Resolved
The intent of this part is to insure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. MI found pitting in dry stores void on the forward bulkhead located underneath the air compressor. Clean and identify extent of pitting in identified area, and provide original plate thickness to satisfaction of the MI. 46 CFR 177.01-5(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2025
Resolved 12 May 2025
Resolution: Vessel cleaned/descaled and added protective coating.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 25 February 2025 Resolved
The intent of this part is to insure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. MI found corrosion in the lazarette on the forward bulkhead water pipe through bulkhead penetration. Clean and identify extent of corrosion in identified area, and provide original plate thickness to satisfaction of the MI. 46 CFR 177.01-5(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2025
Resolved 12 May 2025
Resolution: Vessel cleaned/descaled and added protective coating.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 February 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Hydraulic steering line in the engine room is leaking onto the port main diesel engine battery box. Conduct repairs to the leaking hydraulic line to the satisfaction of the MI. 46 CFR 115.830(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2025
Resolved 12 May 2025
Resolution: Tightened hose to prevent leakage.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 February 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems. MI found worn inlet fuel hose for the aft most fuel filter for the aft generator. Conduct repairs to the worn fuel hose to the satisfaction of the MI. 46 CFR 115.804
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2025
Resolved 12 May 2025
Resolution: Replaced fuel hose.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 February 2025 Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment,and reasonably safe from electrical shock of personnel. Dead end wires found on the exterior stern of the vessel above the A/C unit. Conduct repairs to remove dead end wires to the satisfaction of the MI. 46 CFR 183.01-5(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2025
Resolved 12 May 2025
Resolution: Removed the dead end wires.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 February 2025 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment. Top side fire station #2 valve for the hose was leaking at the valve stem. Conduct repairs to valve stem to the satisfaction of the MI. 46 CFR 115.810(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2025
Resolved 12 May 2025
Resolution: Tightened bonet to prevent leakage.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 February 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. MI found exposed nails and drill bit in the overhead of the starboard side sewage tank void. Conduct repairs to remove hazards to the satisfaction of the MI. 46 CFR 115.830(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2025
Resolved 12 May 2025
Resolution: Removed exposed overhead nails.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 25 February 2025 Resolved
Penetrations and openings in watertight bulkheads must have means to make them watertight. MI found numerous through bulkhead penetrations were not watertight for required watertight bulkheads on frames 4, 11, 19, and 27. Conduct repairs to the through bulkhead penetrations lacking watertight integrity to the satisfaction of the MI. 46 CFR 171.114(a)(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2025
Resolved 21 May 2025
Resolution: Vessel sent photos of through bulkhead penetration repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 25 February 2025 Resolved
On a vessel on an exposed or partially protected route, a watertight coaming with a height of at least 150 millimeters (6 inches) must be provided under each weathertight door in a cockpit or a well, or on the main deck of a flush deck vessel. Vessel had no coamings on the main deck for the door leading outside to the bow and door leading outside to the stern. Conduct repairs to install coamings with the proper height to the satisfaction of the MI. 46 CFR 116.1160(d)(1)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2025
Resolved 25 March 2025
Resolution: Vessel wants to submit exemption letter to MSC to be exempt from following this regulation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 February 2025 Resolved
Each life jacket must be marked with Type I retro reflective material approved in accordance with § 164.018 in subchapter Q of this chapter. MI found 6 adult life jackets with wasted retro. Vessel conducted satisfactory repairs to all 6 life jackets. 46 CFR 122.604(h)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 25 February 2025
Resolution: Vessel replaced retro on all 6 life jackets to the satisfaction of the MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 25 February 2025 Resolved
On a vessel on an exposed or partially protected route, a watertight coaming with a height of at least 150 millimeters (6 inches) must be provided under each weathertight door in a cockpit or a well, or on the main deck of a flush deck vessel. Vessel had no coamings on the main deck for the door leading outside to the bow and door leading outside to the stern. Submit exemption request to MSC or submit repair proposal to MI and conduct repairs to the satisfaction of the MI at vessels next haul out. Vessels route is restricted to protected waters until vessel receives approval letter from MSC for the exemption or vessel installs 6 inch coamings. 46 CFR 116.1160(d)(1)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 19 May 2026
Resolution: Operator installed coaming on main deck door leading to the bow. Vessel was granted an exemption for main deck door leading to the stern.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 April 2024 Resolved
Portable fire extinguishers shall be installed and located to the satisfaction of the Officer in Charge, Marine Inspection. 10-B:C fire extinguisher in engine room must be replaced with a 40-B:C fire extinguisher IAW with COI requirement. 46 CFR 181.30-10(b) OLD T.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2024
Resolved 28 May 2024
Resolution: Operator has correct etinguisher in the vacinty of the e/r
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 March 2023 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel only had 260 adult life jackets. Vessel is limited to 260 adults until able to procure and properly store 44 additional adult life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 May 2023
Resolution: Obtained new life preservers
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 9 March 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; Light in starboard portion of engine room is missing cover. Repair light fixture to the satisfaction of the marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2023
Resolved 17 May 2023
Resolution: Repaired light fixture
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 June 2022 Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level in each of the following normally unmanned spaces. The engine room and lazarette failed to sound at the operating station during operational tests. 46 CFR 119.530(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2022
Resolved 28 June 2022
Resolution: Vessel rep provided video of high water level alarms working SAT.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 June 2022 Resolved
All griddles, broilers, and deep fat fryers must be fitted with a grease extraction hood that complies with 46 CFR 118.425. There are no evidence that the extraction hood over the installed griddle meets UL 710, and no fire extinguishing system is installed. 46 CFR 118.400(e)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2022
Resolved 19 May 2026
Resolution: Operator does not use griddle. Operator removed power from the griddle. Updating deficiency to special note to verify griddle remains not in use at each annual inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 June 2022 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. The center helm pump piping is leaking from several fittings. 46 CFR 122.100
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2022
Resolved 28 June 2022
Resolution: Vessel's rep tightened loose fitting and provided video/pictures. No further leaks
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 May 2021 Resolved
At each initial and subsequent inspection for certification the marine inspector shall examine and test the following items to the extent necessary to determine that they are in proper operating condition and fit for the service for which they are intended: Sea valves and bulkhead closure valves. All overboard discharge and intake valves shall be checked. Fore peak overboard bilge discharge valve inoperable. Fix valve. 46 CFR 176.25-10 (a)(6) OLD T
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 5 May 2021
Resolution: Valve linkage was put back together. Valve operable
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 May 2021 Resolved
Each fixture globe, lens, or diffuser must have a high strength guard or be made of high strength material. Light fixture in engine room missing guard. Provide guard. 46 CFR 111.75-20 (b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2021
Resolved 21 May 2021
Resolution: Operator sent picture of new guard in place over light in engine room.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 14 May 2018 Resolved
THE GENERAL CONSTRUCTION OF THE VESSEL SHALL BE SUCH AS TO MINIMIZE FIRE HAZARDS INOSFAR AS REASONABLE AND PRACTICABLE. VESSELS THAT CARRY MORE THAN 150 PASSENGERS SHALL MEET THE REQUIREMENTS OF 46 CFR 72.05 OF SUBCHAPTER H. AREAS AROUND BOTH ENGINE ROOM SOFT PATCHES AND AFT ENGINEROOM BULKHEAD ARE MISSING REQUIRED STRUCTURAL FIRE PROTECTION INSULATION.46CFR177.10-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2018
Resolved 5 February 2019
Resolution: Corrected during dry dock 07 JAN 2019
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 14 August 2017 Resolved
Prove adequate means of recovering unconscious man overboard while underway; utilizing full sized Oscar, to the satisfaction of the attending marine inspector, prior to carrying passengers. 46CFR185.25-10
Action required: 705 - Other - as specified
Due 25 August 2017
Resolved 8 September 2017
Resolution: MOB drill conducted sat.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 29 March 2017 Resolved
Restore retro-reflective tape on 20 child sized life jackets. 46CFR180.25-25
Due 12 April 2017
Resolved 14 April 2017
Navigation › Piloting/Steering › Coast Guard Light List
Issued 29 March 2017 Resolved
Provide updated Coast Guard Light List.
Due 12 April 2017
Resolved 29 March 2017
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 29 March 2017 Resolved
Provide updated Tide/Tidal Current Tables
Due 12 April 2017
Resolved 29 March 2017
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 14 March 2016 Resolved
Apply retro-reflective tape to 07 Adult and 04 Child PFD's
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 25 April 2016
Resolution: Owner opted to purchase new PFD's: 07 Adult and 04 Child
Lifesaving › Lifefloat › Painter
Issued 14 March 2016 Resolved
Secure life floats with painter lines to each weak link and ajoining life float.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 25 April 2016
Resolution: Life floats secured with painter lines to each weak link and ajoining life float.
Lifesaving › Lifefloat › Serviceable
Issued 14 March 2016 Resolved
Replace 15 passenger Life Float. Restricted to 203 pasengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 25 April 2016
Resolution: New 15 passenger life float installed on roof of operator station cabin.
Lifesaving › Lifefloat › Paddle
Issued 14 March 2016 Resolved
Install 04 paddles for 02 Life Floats.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 25 April 2016
Resolution: 04 paddles secured with 02 life floats on stern.

Casualty record · 2

3 July 2008Routine · role: Moored/Anchored in Vicinity of Primary Subject · serious marine incident, as classified · 1 injured · activity 3261830
30 March 2026Routine · role: Involved in a Marine Casualty · activity 8338815
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

ESCAPE (2008). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.