Records from 2007 to 2026. Most recent: inspection, 20 May 2026.
Inspection history · 25
20 May 2026
MSP Additional Oversight - Risk Assessment · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8376746
20 January 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8298443
2 September 2025
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8225158
21 April 2025
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8115952
20 June 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7932705
11 March 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7876200
4 March 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7874014
13 December 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7838720
28 November 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7830710
20 November 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7827481
17 August 2023
Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7770524
18 July 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7746031
17 April 2023
In-Service Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7669976
22 March 2022
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7416282
21 December 2021
Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7364576
10 August 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7028800
10 December 2019
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6870782
4 June 2019
Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6702947
8 November 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6577266
7 June 2018
MTSA Verification · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6436945
29 December 2017
Administrative Inspection
Administrative · Navigation Center · Activity 6330205
16 November 2017
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6581993
8 March 2017
Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6100597
5 July 2016
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5933019
8 June 2016
Excursion Permit
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5901351
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 20 May 2026
Resolved
Exhaust piping shall be led to the point of escape with a minimum number of bends or elbows. It shall be gastight throughout its length and shall be properly supported by non-combustible hangers or blocks.
MI observed exhaust leak on STBD MDE.
46 CFR 182.20-20(a)
"Old T"
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2026
Resolved 23 June 2026
Resolution: Recieved photo of newly installed exhaust bellow for STBD MDE.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 20 January 2026
Resolved
The construction & arrangement of a vessel must allow the safe operation of the vessel... giving consideration to provision of a seaworthy hull. MI observed hull dent surpassing 1.5 ft prior credit dry dock, Crop & Renew up to 1 frames of good metal. 46 CFR 116.100 (a)
Action required: 705 - Other - as specified
Resolved 29 April 2026
Resolution: MI's observed NDT ALL SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 January 2026
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment... under all practicable conditions. MI observed bilge pumps unable to be tested. Prior to credit Drydock, test all bilge pumps. 46 CFR 119.500
Action required: 705 - Other - as specified
Resolved 20 May 2026
Resolution: All bilge pumps tested
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 20 January 2026
Resolved
Deck rails must be designed & constructed to withstand a point load of 91 kilograms (200 lbs) applied at any point in any direction. MI observed corroded deck rail posts port of the wheelhouse. Refit with new posts prior credit Drydock.
46 CFR 116.900 (b)
Action required: 705 - Other - as specified
Resolved 29 April 2026
Resolution: Vsl provied photos of deck rails renewed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 January 2026
Resolved
MI's observed areas beneath the port side EM exit sliding doors completely corroded. Rectify prior next Drydock.
Action required: 705 - Other - as specified
Resolved 20 May 2026
Resolution: MI's observed crop & renewed sliding door frame
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 20 January 2026
Resolved
MI's observed kick pipes in overhead lazarette deck fixed with cloth rendering area not completely weather tight. Rectify prior next Drydock.
Action required: 705 - Other - as specified
Resolved 20 May 2026
Resolution: MI's observed laz space completely watertight
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 January 2026
Resolved
MI observed space above sewage tank inaccessible due to vessel design & obstructions. Prior next drydock provide UT shots of the above mentioned space
Action required: 705 - Other - as specified
Resolved 20 May 2026
Resolution: MI's observed UT Shots of subject vessel ALL SAT
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 21 April 2025
Resolved
"WHEN OPERATING A VESSEL... THE OPERATOR MUST SECURE EACH TYPE I OR TYPE III... ACCEPTABLE METHODS OF SECURING THE DEVICE INCLUDE: PADLOCKING THE OVERBOARD DISCHARGE VALVE IN THE CLOSED POSITION." VESSEL'S MSD OVERBOARD VALVE WAS UNSECURED. LOCK OR SECURE THE VALVE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2025
Resolution: Lock provided.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 21 April 2025
Resolved
"EACH DOOR... USED AS A MEANS OF ESCAPE MUST BE CAPABLE OF BEING OPENED BY ONE PERSON..." DOOR ON DECK ABOVE MAIN, ON PORT SIDE FORWARD, WAS FOUND LOCKED IN FAST ROUTE, WITH CREW UNABLE TO FIND KEY OR OPEN. ENSURE DOOR CAN BE OPENED.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2025
Resolution: Door repaired.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 March 2024
Resolved
"A vessel that is exposed to salt water more than three months in any 12 month period... must undergo a dry dock examination and internal structural at least once every two years..." Vessel lapsed its DDX/ISE inspection. Complete Credit DDX and ISE prior to carrying passengers.
46 CFR 115.600(c)(1)
46 CFR 115.600(c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2024
Resolution: Credit DDX was given
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 December 2023
Resolved
The intent of this part is to insure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation. The vessel broke one starboard bow window via allision while at Pier 40.
Provide or conduct the following, prior to carrying passengers:
1. Causal analysis report for the allision that occurred on December 12th, 2023.
2. Being the third allision since August 2023 at Pier 40, provide a risk mitigation plan for future moorings at Pier 40.
3. Complete temporary repair of window to the satisfaction of Coast Guard Marine inspector
"OLD T"
46 CFR 177.01-5(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2023
Resolution: Vessel completed temp window repair.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 December 2023
Resolved
Prior to credit DDX complete the following:
1. Repair the window to the satisfaction of a CG Marine Inspector
Action required: 705 - Other - as specified
Resolved 2 April 2024
Resolution: Credit DDX was given
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 December 2023
Resolved
Notice of casualty-- "Immediately after the addressing of resultant safety concerns, the owner, agent, master, or person in charge of a vessel... an occurrence materially and adversely affecting the vessel's seaworthiness or fitness for service or route..." A notification of broken window was not made known prior to inspection.
46 CFR 185.202(a)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2023
Resolution: Vessel has been instructed to maka sure proper notifications are made in the event of a marine casualty.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 November 2023
Resolved
A number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided. Vessel reported having only 32 child size life jackets on board due to breach of security. Vessel is restricted to carrying 311 passengers until proper number of life jackets are returned on board.
Action required: 705 - Other - as specified
Resolved 15 December 2023
Resolution: Vessel purchased new lifejackts.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 November 2023
Resolved
The vessel owner or operator must ensure the implementation of security measures to: control access to the vessel. Vessel reported breach of security where individual(s) gained access to the vessel overnight. Conduct security audit prior to carrying passengers.
Action required: 10 - Deficiency Rectified
Resolved 21 November 2023
Resolution: Recieved audit to the satisfaction of the attending MI
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 July 2023
Resolved
Vessel experienced an engine room fire (Cause to be determined)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 August 2023
Resolution: Issue of fire was determined and the damage from the fire has been rectified.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 17 April 2023
Resolved
Emergency remote shut off for engine room exhaust fan not operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 2 May 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 March 2022
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail.
The forward section of the port/starboard main engines missing guard rails.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 April 2022
Resolved 29 March 2022
Resolution: MI received photograph of guard over exposed machinery for each main engines.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 June 2019
Resolved
POST 2019 CHART ON BRIDGE.
Action required: 705 - Other - as specified
Due 12 June 2019
Resolved 13 June 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 June 2019
Resolved
MOUNT FIRE AXE INSIDE BRIDGE.
Action required: 705 - Other - as specified
Due 12 June 2019
Resolved 13 June 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 June 2019
Resolved
Wire splice inside port cabinet door on "New Mar" device shall be made in an enclosure (junction box).
Action required: 705 - Other - as specified
Due 12 June 2019
Resolved 13 June 2019
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 4 June 2019
Resolved
Service isolation valve for collision bulkhead bilge pipe. Submit video of hand operation via remote valve.
Action required: 705 - Other - as specified
Due 12 June 2019
Resolved 13 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 4 June 2019
Resolved
Cover all insulation in PFD Storage areas.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2019
Resolution: PICS SUBMITTED.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 June 2019
Resolved
Stbd locker inboard eye level: Junction box needs cover.
Action required: 705 - Other - as specified
Due 12 June 2019
Resolved 13 June 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 June 2019
Resolved
All high level bilge alarm wire connections must be made in an enclosure (junction box).
Action required: 705 - Other - as specified
Due 12 June 2019
Resolved 13 June 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 June 2019
Resolved
Port locker breaker box missing dead cover.
Action required: 705 - Other - as specified
Due 12 June 2019
Resolved 13 June 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 June 2019
Resolved
Port locker outboard junction box needs cover and protection from water source leaking on it.
Action required: 705 - Other - as specified
Due 12 June 2019
Resolved 13 June 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 June 2019
Resolved
Post Restricted Access sign above port & stbd locker stairwell.
Action required: 705 - Other - as specified
Due 12 June 2019
Resolved 13 June 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 June 2019
Resolved
SECURITY: Vessel had not conducted a security drill in over 1 year.
Action required: 10 - Deficiency Rectified
Resolved 4 June 2019
Resolution: ran a drill in our presence.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 8 November 2018
Resolved
Vsl is broadcasting incorrect Name and Vsl is broadcasting incomplete dimension information (AIS Antenna Position "X" equals 0)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 1 July 2022
Resolution: Vessel is broadcasting correct information on AIS.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 8 March 2017
Resolved
Cover black paint on all life jackets with retroflective tape. If over 50 percent of orange has been covered with retroflective tape, the life jacket will be condemed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 March 2017
Resolved 9 March 2017
Resolution: Attend vessel and all life jackets were painted international orange with the appropriate amount of retroflective tape.
Engineering › Steering Gear System › Pin
Issued 8 March 2017
Resolved
Repair clevis pin on the steering system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 March 2017
Resolved 9 March 2017
Resolution: Attended vessel and tested steering system. All sat.
Electrical › Electric Supply System (service) › Cable
Issued 8 March 2017
Resolved
Remove all 16AWG cable on bridge cousole if on power or lighting circut. Put all wire splices inside of an enclosure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 10 May 2017
Resolution: Recieved photographs from operator clearing the def.
Communications › Alarms/Indicators › Bilge Alarm
Issued 13 July 2016
Resolved
Vessel's bilge alarm's for the laz and galley spaces are not displaying a visual alarm indication. Vessel must repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 July 2016
Resolved 14 July 2016
Resolution: Received email with pictures showing all visual bilge alarms are properly working.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 13 July 2016
Resolved
Vessel must provide the following DAPI information: Company Policy; Crew List and EAP enrollment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2016
Resolved 14 July 2016
Resolution: Received email with proof of Company policy, crew list, and EAP enrollment.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 July 2016
Resolved
Vessel must undergo an annual inspection within 3 months of COI date (03APR) PTCP
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2016
Resolution: Vessel completed fourth annual inspection.