Records from 2016 to 2025. Most recent: inspection, 2 December 2025.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 December 2025
Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed. STBD engine in inoperable due to maintenance and repairs. Repairs to the STBD engine and sea trials required prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 December 2025
Resolution: STBD Engine repaired. Sea Trial complete.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 December 2025
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. (1)The light fixture in the port side engine space is not properly secured. Secure the light fixture. (2) An electrical connection in the engine room was secured using a wire nut. Repair the wire to the satisfaction of the Marine Inspector. (3) An open enclosure with exposed wire was identified in the starboard wheelhouse. Install a cover on the enclosure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2025
Resolved 29 December 2025
Resolution: Cover installed on enclosure.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 2 December 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Dead end wire found in port outboard side of switchboard. Repair or remove wire.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2025
Resolved 29 December 2025
Resolution: Wire removed.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 2 December 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Insulation on the shore tie receptacle has been removed, and a combustible line was attached to it. Insulation must be continuous up to the fitting.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2025
Resolved 6 January 2026
Resolution: Received photographic evidence of repair to shore tie
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 December 2025
No resolution recorded
Acid batteries shall be located in a tray of lead or other suitable material resistant to deteriorating action by the electrolyte. Excessive corrosion is present on the port side battery box, and the inboard support has been cut, rendering the support ineffective. Clean the battery space and repair or replace the battery box as necessary.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2026 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 December 2025
Resolved
In systems and applications where flexible hoses are permitted to be clamped. Two clamps must be used on each end of the hose, or one hose clamp can be used if the pipe ends are expanded or beaded to provide a positive stop against hose slippage. Install double hose clamps on all required hoses on the port engine to comply with applicable standards and ensure safe operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2026
Resolved 29 December 2025
Resolution: Double hose clamps installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 December 2025
Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 150 F, must be suitably insulated where necessary to prevent injuries. Install appropriate exhaust lagging on port and stbd side aft bulkhead of engine room and port side of shaft compartment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2026
Resolved 29 December 2025
Resolution: Lagging installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 December 2025
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments under all practical conditions. Secure the bilge pump to the deck to ensure safe and reliable operation as per manufacturer.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2026
Resolved 29 December 2025
Resolution: Bilge pump secured.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 December 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(1) Charts of large enough scale to make safe navigation possible. Vessel did not have updated navigation charts.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2026
Resolved 29 December 2025
Resolution: Charts updated.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 2 December 2025
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Placard for model # 8830A missing, post placards.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 December 2025
Resolution: Placard installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 December 2025
Resolved
Where life preservers are stowed so that they are not readily visible to passengers, the containers in which they are stowed shall be marked "Life Preservers" and with the number contained therein, in at least 1- inch letters and figures. This legend should indicate the separate stowage of children's life preservers. Label child lifejackets storage space.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 January 2026
Resolution: Received photographic evidence of Proper signage.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 December 2024
Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practicable. MI identified several areas overhead in the engine room missing essential Structural Fire Protection. Adequately address the SFP.
46 CFR 177.10-5 OLD T
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2024
Resolution: Structual fire protection adequately addressed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 December 2024
Resolved
...each life jacket must be approved in accordance with either §§ 160.002, 160.005, or 160.055 in subchapter Q of this chapter, or other standard. MI observed approximately 73 life-jackets with unsatisfactory retro-reflective tape. Repair/replace.
46 CFR 117.71 (c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2024
Resolution: Life jackets replaced/repaired. O/O confirmed 403 (above requried amount) available on board.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 December 2024
Resolved
The intent of this part is to insure that each vessel is provided with safe, readily available and sufficient firefighting equipment of the type necessary to extinguish any fires which are likely to be encountered in normal operation.” No firefighting equipment service records were on board to review. Provide records.
46 CFR 181.01-5(a)OLD T
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2024
Resolution: Out of service fire extingiushers replaced with new.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 December 2024
Resolved
A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys of not less than 610 millimeters (24 inches) in diameter. MI observed 01 life buoy missing. Replace within 7 days.
46 CFR 117.70(a)(3)
Action required: 705 - Other - as specified
Resolved 12 December 2024
Resolution: Life buoy replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 3 December 2024
Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry:(1) Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.121; and(2) Three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel had 03 expired orange flares w/o any other viable options onboard. Ensure vessel had required amount of flares on board within 7 days.
46 CFR 117.68 (b)(1)(2)
Action required: 705 - Other - as specified
Resolved 12 December 2024
Resolution: 3 smoke flares and 3 red hand flares available onboard.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 3 December 2024
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Max pax of 288 was not marked on 2nd deck. Rectify with signage w/in 7 days.
46 CFR 122.602 (f)
Action required: 705 - Other - as specified
Resolved 12 December 2024
Resolution: Max pax marked on top deck.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 December 2024
Resolved
An exposed hazard, such as gears or rotating machinery, must be protected by a cover, guard, or rail. MI observed exposed gears/rotating machinery on port side generator. Replace within 7 days.
46 CFR 116.960
Action required: 705 - Other - as specified
Resolved 12 December 2024
Resolution: Machinery guard installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 December 2024
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection.” MI identified several lights on the switchboard in the engine room are extinguished. Ensure all lights work as intended.
46 CFR 183.01-15 OLD T
Action required: 705 - Other - as specified
Resolved 12 December 2024
Resolution: Switchboard lights replaced and in good working order.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 December 2024
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. During high level bilge alarm tests, the shaft void and engine room high level alarms failed to illuminate or alarm at the bridge. Ensure all high level bilge alarms are functioning within 30 days.
46 CFR 183.01-15 OLD T
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 December 2024
Resolution: E/R and void shaft space high bilge alarms confirmed alarming on bridge.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 December 2024
Resolved
Each life jacket carried on board the vessel must be marked in accordance with 122.604 of this chapter. There were no signs or labels posted at stowage location for child life jackets. Ensure child life jackets are adequately labeled within 30 days.
46 CFR 117.71 (e)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 December 2024
Resolution: Child life jackets location marked.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 December 2024
Resolved
The intent of this part is to insure that each vessel is provided with safe, readily available and sufficient fire fighting equipment of the type necessary to extinguish any fires which are likely to be encountered in normal operation.. MI observed noticeable leak on fire pump in engine room. Address leak within 30 days.
46 CFR 181.01-5 (a)OLD T
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 December 2024
Resolution: Leak on fire pump rectified.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 December 2024
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. MI observed a junction box for the ventilation fan located in sewage tank space missing cover. Additionally MI identified an obstruction in the ventilation fan. Address both the cover and obstruction within 30 days.
46 CFR 183.01-15 OLD T
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 December 2024
Resolution: Onstruction removed. Fan is out of service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 December 2024
Resolved
The intent of this part is to insure that the main propulsion machinery installed on each vessel is suitable for the vessel and its operation…” During testing, the starboard main engine was unable to be secured from the pilot house. Ensure the starboard ME can be secured as designed.
46 CFR 182.01-5 (a)OLD T
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 December 2024
Resolution: Confirmed ME can be secured from bridge.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 December 2024
Resolved
Switches other than those mounted on the switchboard shall be of the enclosed type.” MI identified start batteries for the Main Engine located outside of a switch box or panel in the engine room. Ensure the batteries are adequately addressed.
46 CFR 183.05-15 OLD T
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 December 2024
Resolution: Switches replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 December 2024
Resolved
The intent of this part is to insure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection.” MI identified chunks of missing fixed ballast underneath the sewages takes, with liquid in the bilge. Remove the liquid for further CG inspection.
46 CFR 177.01-5 (a)OLD T
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 December 2024
Resolution: Liquid removed and space inspected by MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 September 2023
Resolved
Vessel is required one mate per COI and allowed to drop to a senior deckhand per routes and conditions; Senior deckhand list was not current and person identified as the "senior deckhand" during inspection does not have the required training and knowledge to serve that position currently as stated to Coast Guard Marine Inspector (CGMI).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2023
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 13 September 2023
Resolved
Vessel must maintain current and up to date charts for intended voyage; vessel's charts were from Mar 2022, must get up to date charts.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2023
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 September 2023
Resolved
Vessel navigational lights must meet UL 1104 and must meet proper arch of viability and distance; vessel's side light were of an unknown type & mounted wrong, the stern light has an unknown new LED bulb.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 September 2023
Resolved
The maximum number of passengers permitted must not be more than that allowed by regulation, vessel has folding chairs throughout the main deck and second deck which does not meet fixed seating criterion; must have CGMI conduct measurements with vessel operator to determine correct passengers allowed by regulation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 September 2023
Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practicable. Vessel must rectify the following electrical hazards.
-Light switch with wasted cover and frayed wire in exhaust void.
-Worn wiring in exhaust void must be replaced and secured with metallic clips IAW regulation.
-All wire penetrations through bulkheads must be vapor tight
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 October 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 September 2023
Resolved
Seating accommodations for passengers are required to be provided when the maximum number of passengers has been determined using the fixed seating criteria in 176.01-25(b) of this sub chapter. Provide updated General Arrangement plan from Naval Architect to determine maximum passenger count. Vessel is restricted to carrying a maximum of 412 passengers until GA plan is provided and accurate passenger count is determined.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 October 2023
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 May 2023
Resolved
A power driven fire pump shall be installed on each mechanically propelled "L" vessel. Fire pump was not operational. 46 CFR 181.10-1(a) OLD T.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 May 2023
Resolved
Firehose nozzle must be bronze or another material that has strength and corrosion resistance properties equal to those of bronze. Vessel's nozzle was plastic. 46 CFR 181.15-10(d)(2) OLD T
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 May 2023
Resolved
Portable fire extinguishers shall be installed and located to the satisfaction of Officer in Charge of Marine Inspections. 03 portable fire extinguishers were not installed properly. 46 CFR 181.30-10(b) OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 12 May 2023
Resolution: Verified installation.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 May 2023
Resolved
All piping, valves, and fittings shall be in accordance with good marine practices and suitable for the purpose intended. The main distribution pipe for the fire main downstream from the sea strainer was damaged. 46 cfr 181.15-5(c)
Action required: 10 - Deficiency Rectified
Resolved 8 May 2023
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 March 2023
Resolved
Repair windows as laid out in proposal. Clips required
on widows being glued in without a metal frame.
Action required: 705 - Other - as specified
Resolved 28 April 2023
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 March 2023
Resolved
Audio Gage engine room and aft void along the centerline to the third longitudinal frame both port and stbd.
Request USCG attendance on day of audio gaging.
Action required: 705 - Other - as specified
Due 11 May 2023
Resolved 27 April 2023
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 March 2023
Resolved
C/R 02 transverse web frames and 03 longitudinal frames in fwd void identified during inspection on 11Apr2023.
Action required: 705 - Other - as specified
Due 11 May 2023
Resolved 28 April 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 14 September 2022
Resolved
MI discovered a hole in the bulkhead between the machinary space and aft void space
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2022
Resolved 17 October 2022
Resolution: Vsl Operator subimitted photos of repairs and testing. MI reviewed all documents and found all to be in satisfactory condition.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 14 September 2022
Resolved
Remove unused pipe that runs through the bulkhead between the tank room and the eng. room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2022
Resolved 17 October 2022
Resolution: Vsl Operator subimitted photos of repairs and testing. MI reviewed all documents and found all to be in satisfactory condition.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 September 2022
Resolved
Emergency fuel shut off valve is easily accessible to passengers. Provide a mean to prevent passengers for pulling valve
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2022
Resolved 17 October 2022
Resolution: Vsl Operator subimitted photos of repairs and testing. MI reviewed all documents and found all to be in satisfactory condition.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 June 2022
Resolved
MI received an anonymous tip that the vessel's hull was damaged while mooring to the pier. After responding, the MI found a hole in the hull of the vessel.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2022
Resolved 22 June 2022
Resolution: MI witnessed satisfactory NDT/repair of vessels hull.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 June 2021
Resolved
Machinery must be maintained in such a manner as to afford adequate protection from machinery failure. Starboard steering hydraulic cylinder leaking. Repair or replace hydraulic cylinder.
Rectify w/in 7 days
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2021
Resolved 13 July 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 June 2021
Resolved
Machinery must be maintained in such a manner as to afford adequate protection from personnel injury. Marine Inspector's gas meter alarmed upon entering shaft alley space. Rectify issue and provide a Marine Chemist Certificate certifying the space as gas free along with a casual analysis. Inform all crew of hazard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2021
Resolved 13 July 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 May 2021
Resolved
Remove scaling from forepeak to permit safe operation of bilge intake
Action required: 705 - Other - as specified
Due 10 June 2021
Resolved 21 June 2021
Resolution: Attended vessel and verified rectification.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 September 2020
Resolved
OWNERS AND OPERATORS MUST MAKE THE VESSEL READY FOR INSPECTION IN ACCORDANCE WITH THIS SUBCHAPTER IF ISSUANCE OF A COI IS DESIRED. PRESENTLY THIS VESSEL HAS MISSED ITS ANNUAL COI INSPECTION AND IS RESTRICTED FROM CARRYING >6 PASSENGERS FOR HIRE. THIS INFORMATION WAS BRIEFED TO THE VESSEL REPRESENTATIVE JAMES SILECCHIA WITH THE UNDERSTANDING THAT THE VESSEL WILL DISCONTIUE COMMERCIAL OPERATIONS UNTIL READY FOR INSPECTION. WHEN READY FOR INSPECTION, THE OWNER/OPERATOR SHALL SUBMIT AN APPLICATION FOR INSPECTION (FORM CG-3752) TO THE EMAIL PROVIDED BELOW PRIOR TO RETURNING TO COMMERICAL OPERATIONS.THE CONDITION OF THE VESSEL, ITS EQUIPMENT AND ANY ASSOCIATED DRY DOCK INSPECTIONS AS NEEDED MUST BE ACCEPTABLE TO THE COGNIZANT OCMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2021
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 4 April 2018
Resolved
Adequate life jackets must be provided for all passengers.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 November 2019
Resolution: Reduced pax count for only the amount of jackets onboard.