Records from 2011 to 2021. Most recent: inspection, 25 May 2021.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 October 2020
No resolution recorded
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel did not complete drydock examination by due date.
46 CFR 176.600(c)(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 October 2020 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 April 2020
No resolution recorded
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Vessel has had outstanding deficiencies for over 7 months pending from its annual inspection on August 18th, 2019. Clear open defs prior to operations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 April 2020 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 September 2019
No resolution recorded
The two required fixed power bilge pumps shall be self-priming and shall each be by different sources of power. Vessel's electrical fire and bilge pump required manual priming. Prove proper operation of electrical fire and bilge pump without manual priming.
46 CFR 182-25-10(a)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 September 2019
No resolution recorded
Inspection of each life jacket. Many of the vessel's life jackets have corroded metal fittings rendering them difficult to don. Prove proper operation of life jackets.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 September 2019
No resolution recorded
Life jackets must be stored in convenient places distributed throughout accommodation spaces. Life jackets are stored above the stairwell. These life jackets are not readily accessible and need to be relocated.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 18 September 2019
No resolution recorded
Each hatch exposed to the weather must be watertight. Hatch to void #3 is currently secured using a piece of wood. Prove hatch complies with 171.124.
46 CFR 171.124
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2019 — due date passed with no resolution recorded
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 18 September 2019
No resolution recorded
Penetrations and openings in watertight bulkheads must have means to make them watertight. Sink drain flows to void #3. Provide means to make sink drain watertight.
46 CFR 171.114
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2019 — due date passed with no resolution recorded
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 18 September 2019
Resolved
Except as otherwise provided in this section, machinery and fuel tank spaces shall be separated from accommodation spaces by watertight and or vapor tight bulkheads of double diagonal wood, marine plywood, steel plate or equivalent. Holes leading from the engine room to the ADA restroom violate vapor tight boundaries. Holes leading from the engine room to the main deck passenger area violate watertight boundaries.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2019
Resolved 17 March 2020
Resolution: Verified that holes had been patched.
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 18 September 2019
No resolution recorded
Exhaust piping shall be led to the point of escape with a minimum number of bends or elbows. MIs on board observed visually with with a gas detector an exhaust leak coming from the starboard M/E's inboard exhaust discharge line. Fix exhaust leak.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2019 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 September 2019
No resolution recorded
Each lighting fixture and lampholder must be fixed.
Corrosion has caused the P/S light adjacent the maneuvering station to be loose. Secure the lighting
fixture.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2019 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 September 2019
No resolution recorded
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use. Grab lines on vessel's BAs are tightly gathered, rendering them difficult to be used in case of an emergency. Stow grab lines so they are ready for immediate use.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2019 — due date passed with no resolution recorded
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 18 September 2019
No resolution recorded
The discharge ends of vent pipes shall terminate on the hull exterior. Corrosion in fuel tank vent piping has caused holes flowing to passenger areas. Fix fuel tank vent piping.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2019 — due date passed with no resolution recorded
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 18 September 2019
No resolution recorded
Spaces containing machinery shall be fitted with at least two ducts to furnish natural or mechanical supply and exhaust ventilation. Corrosion in engine room ventilation has caused holes flowing to passenger areas. Fix engine room ventilation piping.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2019 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 September 2019
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041. Vessel's first aid kit was expired. First aid kit was replaced.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 18 September 2019
Resolved 18 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 November 2018
Resolved
Each major generator shall be fitted with a nameplate of corrosion-resistant material. Generator #1 was missing its nameplate.
46 CFR 183.10-5(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 November 2018
Resolved 6 November 2018
Resolution: Vessel rep produced new nameplates with manufacturer specs and posted onto generator.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 2 November 2017
Resolved
Prove proper operation of lighting in engine room. 46CFR183.432(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 28 November 2017
Resolution: Fixed and proved proper operation of emergency lighting in the engine.
Construction/Loadline › Structures › Superstructure
Issued 2 November 2017
Resolved
Repair holes on main deck in bulkheads (scattered throughout). 46CFR176.25-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2018
Resolved 22 March 2019
Resolution: Repaired in 2018 Drydock
Electrical › Electric Supply System (service) › Battery Installation
Issued 1 September 2016
Resolved
24V battery installation under pilothouse unsecured. Secure batteries from shifting. 46 CFR 183.05-20
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 September 2016
Resolved 13 September 2016
Resolution: Secured batteries from shifting.
Electrical › Electric Supply System (service) › Battery Installation
Issued 1 September 2016
No resolution recorded
Submit plans to OCMI detailing 24V system under pilothouse to include; load calculations, over current protection, and wire sizing. 46 CFR 176.700
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 November 2016 — due date passed with no resolution recorded
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 1 September 2016
Resolved
04 ring buoys inspected missing required lifeline around 01 ring buoy. Provide lifeline around body of ring bouy. 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2016
Resolved 1 September 2016
Resolution: Provided appropriate lifeline IAW 46 CFR 180.70
Construction/Loadline › Hull › Longitudinal Frame
Issued 1 September 2016
Resolved
Stiffeners on longitudinal in steering gear compartment severely corroded and painted over. Submit repair proposal to OCMI. 46 CFR 176.404
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 22 March 2019
Construction/Loadline › Hull › Transverse Frame
Issued 1 September 2016
Resolved
Cracked welds on port frames between stiffeners 3 & 4 in #4 aft space. Submit repair proposal to OCMI. 46 CFR 176.404
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 22 March 2019
Electrical › Electrical Distribution System (service) › Junction Box
Issued 1 September 2016
Resolved
Junction in overhead in steering space spliced incorrectly at fan connection. Make correct connections in junction box. 46 CFR 183.340
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 October 2016
Resolved 7 October 2016
Resolution: Placed spliced wire in junction box.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 1 September 2016
Resolved
Wire spliced incorrectly in 32V charger system in pilot house. Make correct connections in junction box. 46 CFR 183.340
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 October 2016
Resolved 7 October 2016
Resolution: Placed spliced wire in junction box.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 September 2016
Resolved
Identified discrepancy between COI and stability letter concerning Max persons. Vessel may operate with a max of 459 persons onboard.
Action required: 705 - Other - as specified
Due 1 September 2016
Resolved 1 September 2016
Resolution: Ensured COI and stability letter have the same max persons listed.