RANGER

RANGER is a 1971 passenger vessel (inspected). The Coast Guard has recorded 95 inspections since 1984, most recently in May 2021, along with 113 deficiencies — 13 with no resolution recorded —, 5 operational controls, 2 with no removal date recorded and 2 casualty investigations between 2011 and 2015.

Records from 1984 to 2021. Most recent: inspection, 25 May 2021.

Built
1971
Last inspected
25 May 2021
Documentation
Valid · documentation file of 10 September 2026
Controls
2 with no removal date recorded

Identity

WDD3855
Flag
UNITED STATES
367137150
Maury page id
psix-46907

Inspections, by type

…with no type recorded18
…past their stated due date10
Years with a record 35 calendar years (1984–2021)
The 95 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)79.9 ft × 27.2 ft × 8.7 ft
Registered tonnagegross 99 / net 71
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · WARREN, RI, UNITED STATES · built 1971
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portALCATRAZ ISLAND, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
71 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD3855MMSI 367137150 · active · compulsorily equipped · granted 15 June 2016, expires 29 August 2026
WZP8602MMSI 367066740 · cancelled · compulsorily equipped · granted 14 September 2005, cancelled 7 November 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

FREEDOM Passenger (Inspected) · MISLE 45600 · 27 July 2004 · activity 2316938

Inspection history · 95

25 May 2021 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7207247
9 October 2020 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7074780
18 September 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6815325
6 November 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6574638
18 June 2018 Examination of Repairs · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6447973
6 June 2018 Drydock Extension
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6436241
28 November 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6314403
2 November 2017 Annual Inspection · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6299791
2 November 2016 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6040832
1 September 2016 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5973834
13 January 2016 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5796596
14 October 2015 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5742441
25 August 2015 Damage Survey · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5226437
25 August 2015 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5226472
25 August 2015 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5228709
21 March 2014 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4815169
14 March 2014 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4816377
24 May 2012 Deficiency Check · DAPI Audit
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4337676
27 February 2012 Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4267290
13 September 2011 COI Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4139336
16 July 2011 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4086122
31 January 2011 DAPI Audit · Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3939456
3 November 2010 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3884400
4 March 2010 DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3690085
1 February 2010 Drydock Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3665930
26 November 2008 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3368623
30 August 2008 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3312893
8 April 2008 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3180282
3 February 2008 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3141083
29 January 2008 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3132148
20 January 2008 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3133514
10 December 2007 DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3138645
15 November 2007 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3102414
6 September 2006 Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2770492
28 August 2006 Deficiency Check · MTSA Verification · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2764867
3 March 2006 Load Line/Change of Employment
Administrative · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2595401
13 February 2006 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2584341
29 July 2005 MTSA Verification
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2443747
25 May 2005 Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2367214
9 September 2004 MTSA Verification
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2192310
27 July 2004 Type not recorded
No type recorded · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2316938
17 May 2004 COI Inspection · Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2067805
18 March 2004 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2026885
23 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978113
30 July 2003 Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1860694
13 November 2002 Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1704431
1 July 2002 Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1639493
15 March 2002 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1491345
6 November 2001 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1408871
18 April 2000 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1386785
3 November 1999 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1458690
10 November 1998 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1472743
2 June 1998 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1130273
15 April 1998 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 788821
14 November 1996 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1175127
21 August 1996 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 18522
20 August 1996 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 659498
8 August 1996 Examination of Repairs · Damage Survey
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1084569
6 August 1996 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 136189
6 August 1996 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 212389
6 August 1996 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 216236
12 June 1996 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1085007
22 April 1996 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1377751
21 November 1995 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 881967
19 June 1995 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 881528
5 May 1995 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1181994
12 July 1994 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1178102
3 July 1994 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 41774
25 May 1994 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1358459
14 January 1994 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1409065
26 May 1993 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1438069
25 May 1993 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1141053
10 March 1993 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1412480
12 July 1992 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1259434
7 July 1992 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1269417
3 June 1992 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 951256
13 April 1992 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1267322
3 June 1991 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 912241
14 May 1991 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1211308
13 February 1991 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 910493
29 May 1990 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 899344
13 February 1990 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 920321
24 May 1989 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 896740
8 December 1988 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 897600
20 May 1988 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1195745
23 December 1987 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1007922
18 June 1987 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1011675
12 February 1987 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1321197
25 November 1986 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1012210
9 October 1986 Credit Drydock
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1317129
29 October 1985 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1301416
25 October 1985 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1299601
3 September 1985 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1297985
24 May 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 988833
29 October 1984 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 975098

Deficiency record · 113

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 October 2020 No resolution recorded
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel did not complete drydock examination by due date. 46 CFR 176.600(c)(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 October 2020 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 April 2020 No resolution recorded
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Vessel has had outstanding deficiencies for over 7 months pending from its annual inspection on August 18th, 2019. Clear open defs prior to operations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 April 2020 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 September 2019 No resolution recorded
The two required fixed power bilge pumps shall be self-priming and shall each be by different sources of power. Vessel's electrical fire and bilge pump required manual priming. Prove proper operation of electrical fire and bilge pump without manual priming. 46 CFR 182-25-10(a)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 September 2019 No resolution recorded
Inspection of each life jacket. Many of the vessel's life jackets have corroded metal fittings rendering them difficult to don. Prove proper operation of life jackets.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 September 2019 No resolution recorded
Life jackets must be stored in convenient places distributed throughout accommodation spaces. Life jackets are stored above the stairwell. These life jackets are not readily accessible and need to be relocated.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 18 September 2019 No resolution recorded
Each hatch exposed to the weather must be watertight. Hatch to void #3 is currently secured using a piece of wood. Prove hatch complies with 171.124. 46 CFR 171.124
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2019 — due date passed with no resolution recorded
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 18 September 2019 No resolution recorded
Penetrations and openings in watertight bulkheads must have means to make them watertight. Sink drain flows to void #3. Provide means to make sink drain watertight. 46 CFR 171.114
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2019 — due date passed with no resolution recorded
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 18 September 2019 Resolved
Except as otherwise provided in this section, machinery and fuel tank spaces shall be separated from accommodation spaces by watertight and or vapor tight bulkheads of double diagonal wood, marine plywood, steel plate or equivalent. Holes leading from the engine room to the ADA restroom violate vapor tight boundaries. Holes leading from the engine room to the main deck passenger area violate watertight boundaries.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2019
Resolved 17 March 2020
Resolution: Verified that holes had been patched.
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 18 September 2019 No resolution recorded
Exhaust piping shall be led to the point of escape with a minimum number of bends or elbows. MIs on board observed visually with with a gas detector an exhaust leak coming from the starboard M/E's inboard exhaust discharge line. Fix exhaust leak.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2019 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 September 2019 No resolution recorded
Each lighting fixture and lampholder must be fixed. Corrosion has caused the P/S light adjacent the maneuvering station to be loose. Secure the lighting fixture.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2019 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 September 2019 No resolution recorded
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use. Grab lines on vessel's BAs are tightly gathered, rendering them difficult to be used in case of an emergency. Stow grab lines so they are ready for immediate use.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2019 — due date passed with no resolution recorded
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 18 September 2019 No resolution recorded
The discharge ends of vent pipes shall terminate on the hull exterior. Corrosion in fuel tank vent piping has caused holes flowing to passenger areas. Fix fuel tank vent piping.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2019 — due date passed with no resolution recorded
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 18 September 2019 No resolution recorded
Spaces containing machinery shall be fitted with at least two ducts to furnish natural or mechanical supply and exhaust ventilation. Corrosion in engine room ventilation has caused holes flowing to passenger areas. Fix engine room ventilation piping.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2019 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 September 2019 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041. Vessel's first aid kit was expired. First aid kit was replaced.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 18 September 2019
Resolved 18 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 November 2018 Resolved
Each major generator shall be fitted with a nameplate of corrosion-resistant material. Generator #1 was missing its nameplate. 46 CFR 183.10-5(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 November 2018
Resolved 6 November 2018
Resolution: Vessel rep produced new nameplates with manufacturer specs and posted onto generator.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 2 November 2017 Resolved
Prove proper operation of lighting in engine room. 46CFR183.432(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 28 November 2017
Resolution: Fixed and proved proper operation of emergency lighting in the engine.
Construction/Loadline › Structures › Superstructure
Issued 2 November 2017 Resolved
Repair holes on main deck in bulkheads (scattered throughout). 46CFR176.25-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2018
Resolved 22 March 2019
Resolution: Repaired in 2018 Drydock
Electrical › Electric Supply System (service) › Battery Installation
Issued 1 September 2016 Resolved
24V battery installation under pilothouse unsecured. Secure batteries from shifting. 46 CFR 183.05-20
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 September 2016
Resolved 13 September 2016
Resolution: Secured batteries from shifting.
Electrical › Electric Supply System (service) › Battery Installation
Issued 1 September 2016 No resolution recorded
Submit plans to OCMI detailing 24V system under pilothouse to include; load calculations, over current protection, and wire sizing. 46 CFR 176.700
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 November 2016 — due date passed with no resolution recorded
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 1 September 2016 Resolved
04 ring buoys inspected missing required lifeline around 01 ring buoy. Provide lifeline around body of ring bouy. 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2016
Resolved 1 September 2016
Resolution: Provided appropriate lifeline IAW 46 CFR 180.70
Construction/Loadline › Hull › Longitudinal Frame
Issued 1 September 2016 Resolved
Stiffeners on longitudinal in steering gear compartment severely corroded and painted over. Submit repair proposal to OCMI. 46 CFR 176.404
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 22 March 2019
Construction/Loadline › Hull › Transverse Frame
Issued 1 September 2016 Resolved
Cracked welds on port frames between stiffeners 3 & 4 in #4 aft space. Submit repair proposal to OCMI. 46 CFR 176.404
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 22 March 2019
Electrical › Electrical Distribution System (service) › Junction Box
Issued 1 September 2016 Resolved
Junction in overhead in steering space spliced incorrectly at fan connection. Make correct connections in junction box. 46 CFR 183.340
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 October 2016
Resolved 7 October 2016
Resolution: Placed spliced wire in junction box.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 1 September 2016 Resolved
Wire spliced incorrectly in 32V charger system in pilot house. Make correct connections in junction box. 46 CFR 183.340
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 October 2016
Resolved 7 October 2016
Resolution: Placed spliced wire in junction box.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 September 2016 Resolved
Identified discrepancy between COI and stability letter concerning Max persons. Vessel may operate with a max of 459 persons onboard.
Action required: 705 - Other - as specified
Due 1 September 2016
Resolved 1 September 2016
Resolution: Ensured COI and stability letter have the same max persons listed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 August 2015 Resolved
Properly repair affected area. Follow Sector SF's Dead Ship Tow requirements if moving from berth.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2015
Resolved 11 September 2015
Resolution: Observed proper repair of the affected area and start/run of stbd generator.
Fire Fighting › Fire Main › Material
Issued 21 March 2014 Resolved
Remove elbow on the fire main in the #3 void (wooden deck) and properly isolate system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2014
Resolved 27 March 2014
Resolution: Elbow piping removed and sytem properly isolated.
Construction/Loadline › Structures › Superstructure
Issued 21 March 2014 Resolved
crop and renew bottom of port boarding door frame
Condition: Improper/Lack of Maintenance
Due 4 April 2014
Resolved 4 April 2014
Resolution: Bottom of door frame renewed.
Construction/Loadline › Structures › Deck Plating
Issued 21 March 2014 Resolved
repair deck fairing starboard of snack bar
Due 4 April 2014
Resolved 4 April 2014
Resolution: Deck fairing repaired
Construction/Loadline › Structures › Superstructure
Issued 21 March 2014 Resolved
crop and renew bottom elbow deck drain port aft inside main deck
Due 4 April 2014
Resolved 4 April 2014
Resolution: bottom elbow of deck drain renewed.
Construction/Loadline › Structures › Deck Plating
Issued 21 March 2014 Resolved
crop and renew deck areas as marked on main deck adjacent to starboard side heads
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2014
Resolved 4 April 2014
Resolution: deck area properly renewed.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 March 2014 Resolved
Do not operate vessel with passengers onboard until Dry Dock Exam has been conducted to the satisfaction of the attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2014
Documentation › Logs/Records › Drug Test Records
Issued 24 May 2012 Resolved
Crewmembers not properly trained prior to assuming safety sensitive positions regarding company's drug and alcohol policy in accordance with 46 CFR 16.401.
Due 24 June 2012
Resolved 24 May 2012
Resolution: DER emailed updated crewmember training template.
Construction/Loadline › Penetrations › Pipe Flange
Issued 13 September 2011 Resolved
Properly dead end through hull pipe in sewage tank room.
Condition: Improper/Lack of Maintenance
Due 13 October 2011
Resolved 14 September 2011
Resolution: Pipe has been properly plugged and welded.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 13 September 2011 Resolved
Provide 30X30 mesh screen for fuel tank vents.
Condition: Improper/Lack of Maintenance
Due 13 October 2011
Resolved 14 September 2011
Resolution: Flame screens installed.
Engineering › Bilge Water Management System › Strainer
Issued 13 September 2011 Resolved
Renew bilge suction strainer in no.2 void.
Condition: Improper/Lack of Maintenance
Due 14 October 2011
Resolved 14 September 2011
Resolution: New strainer installed.
Documentation › Logs/Records › Drug Test Records
Issued 31 January 2011 Resolved
All required personnel are not in the random drug testing pool as required by 46 CFR 16.230. C/TPA informed of discrepancy and testing pool updated. Individual that was accidentally excluded from pool was immediately subjected to drug test and removed from safety sensitive functions until test results return from lab.
Due 2 March 2011
Resolved 31 January 2011
Documentation › Logs/Records › Drug Test Records
Issued 31 January 2011 Resolved
Copy of latest MIS form not available for review as required by 46 CFR part 16.500.
Due 2 March 2011
Resolved 3 February 2011
Resolution: Received electronic copy of MIS report.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 3 November 2010 Resolved
Properly repair fire pump mechanical seal and prove proper operation.
Due 18 November 2010
Resolved 21 December 2010
Construction/Loadline › Hull › Bottom Plating
Issued 1 February 2010 Resolved
Provide repair proposals for the keel area damaged by yard, and hole in port rudder. (In accordance with NVIC 7-68).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 February 2010
Construction/Loadline › Structures › Superstructure
Issued 1 February 2010 Resolved
Provide repair proposals for the following areas; port side pilot house door, port side exterior light mount on 2nd deck, stbd side engine room exhaust ducting and affected deck plating.
Due 1 March 2010
Resolved 4 March 2010
Construction/Loadline › Hull › Bottom Plating
Issued 1 February 2010 Resolved
Affect repairs in accordance with approved repair proposals.
Action required: 705 - Other - as specified
Due 1 March 2010
Resolved 4 March 2010
Documentation › Logs/Records › Drug Test Records
Issued 10 December 2007 Resolved
Company policy missing as required by 46 CFR part 16.401.
Due 10 January 2008
Resolved 1 February 2008
Documentation › Logs/Records › Drug Test Records
Issued 10 December 2007 Resolved
Security of records not maintained in accordance with 49 CFR 40.333.
Due 10 January 2008
Resolved 1 February 2008
Documentation › Logs/Records › Drug Test Records
Issued 10 December 2007 Resolved
Documentation of pre-employment testing not kept for entire employment period as required by 46 CFR 16.260.
Due 10 January 2008
Resolved 10 December 2007
Documentation › Logs/Records › Drug Test Records
Issued 10 December 2007 Resolved
Drug and alcohol history checks not being completed as required by 49 CFR 40.25.
Due 10 January 2008
Resolved 1 February 2008
Documentation › Logs/Records › Drug Test Records
Issued 10 December 2007 Resolved
Random drug testing was found to not be conducted in accordance with 46 CFR 16.230. Company unsure if testing rate is greater than or equal to 50% annually.
Due 10 January 2008
Resolved 1 February 2008
Documentation › Logs/Records › Drug Test Records
Issued 10 December 2007 Resolved
Statistically based method not currently being used to determine when random testing takes place as required by 46 CFR part 16.230.
Due 10 January 2008
Resolved 1 February 2008
Documentation › Logs/Records › Drug Test Records
Issued 10 December 2007 Resolved
All required personnel are not in the random drug testing pool as required by 46 CFR 16.230.
Due 10 January 2008
Resolved 1 February 2008
Documentation › Logs/Records › Drug Test Records
Issued 10 December 2007 Resolved
Employee assistance program statement not posted as required by 46 CFR 16.401.
Due 10 January 2008
Resolved 1 February 2008
Documentation › Logs/Records › Drug Test Records
Issued 10 December 2007 Resolved
Employee Assistance Program (EAP) hotline phone number not posted as required by 46 CFR part 16.401.
Due 10 January 2008
Resolved 1 February 2008
Documentation › Logs/Records › Drug Test Records
Issued 10 December 2007 Resolved
Crewmembers not properly trained prior to assuming safety sensitive positions regarding company's drug and alcohol policy in accordance with 46 CFR 16.401.
Due 10 January 2008
Resolved 1 February 2008
Documentation › Logs/Records › Drug Test Records
Issued 10 December 2007 Resolved
Supervisors had not received 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR part 16.401.
Due 10 January 2008
Resolved 14 April 2008
Documentation › Logs/Records › Drug Test Records
Issued 10 December 2007 Resolved
Company does not have a Substance Abuse Professional (SAP) name and contact information to make available to employees, per 49 CFR 40.287.
Due 10 January 2008
Resolved 7 February 2008
Documentation › Logs/Records › Drug Test Records
Issued 10 December 2007 Resolved
MIS form not submitted by March 15 as required by 46 CFR part 16.500.
Due 10 January 2008
Resolved 1 February 2008
Documentation › Logs/Records › Drug Test Records
Issued 10 December 2007 Resolved
Copy of latest MIS form not available for review as required by 46 CFR part 16.500.
Due 10 January 2008
Resolved 1 February 2008
Documentation › Logs/Records › Drug Test Records
Issued 10 December 2007 Resolved
No copy of contract or proof of enrollment in Consortium as required by 46 CFR 16.
Due 10 January 2008
Resolved 1 February 2008
Documentation › Logs/Records › Drug Test Records
Issued 10 December 2007 Resolved
Covered employees list not up to date in accordance with 46 CFR 16.230.
Due 10 January 2008
Resolved 1 February 2008
Documentation › Logs/Records › Drug Test Records
Issued 15 November 2007 Resolved
Provide proof of company Drug and Alochol Program policy.
Due 15 December 2007
Resolved 15 November 2007
Electrical › Electric Generation Source (service) › Conductor
Issued 15 November 2007 Resolved
Replace electrical welding cables in way of generator jumper wiring with Marine Grade, UL approved Boat Cable.
Due 15 December 2007
Resolved 15 November 2007
Documentation › Certificates/Documents › FCC SSL
Issued 15 November 2007 Resolved
Provide proof of current FCC SSL. Proof may be emailed or faxed to [phone withheld].
Due 15 December 2007
Resolved 15 November 2007
Construction/Loadline › Structures › Door
Issued 3 March 2006 Resolved
Install a minimum 1/2 inch thick plywood blank over all lower passenger cabin windows and port lights with thru bolts thru the cabin sides at each window.
Action required: 705 - Other - as specified
Due 3 March 2006
Resolved 10 March 2006
Resolution: Attended vessel afloat dockside and found this item satisfactory this date.
Construction/Loadline › Structures › Door
Issued 3 March 2006 Resolved
Repair each amidships sliding door with new rubber weather seals at all four sides to make both doors weather tight and perform a satisfactory hose test at 60 psi to satisfaction of USCG inspector.
Action required: 705 - Other - as specified
Due 3 March 2006
Resolved 10 March 2006
Resolution: Attended vessel afloat dockside and found this item satisfactory this date.
Construction/Loadline › Structures › Door
Issued 3 March 2006 Resolved
Close and seal aft stbd sliding door to make watertight and perform a satisfactory hose test at 60 psi to satisfaction of USCG inspector.
Action required: 705 - Other - as specified
Due 3 March 2006
Resolved 10 March 2006
Resolution: Attended vessel afloat dockside and found this item satisfactory this date.
Construction/Loadline › Structures › Door
Issued 3 March 2006 Resolved
Repair aft cabin sliding door with new rubber weather seals at all four sides to make both doors weather tight and perform a satisfactory hose test at 60 psi to satisfaction of USCG inspector.
Action required: 705 - Other - as specified
Due 3 March 2006
Resolved 10 March 2006
Resolution: Attended vessel afloat dockside and found this item satisfactory this date.
Construction/Loadline › Structures › Door
Issued 3 March 2006 Resolved
Remove and stow aft cockpit bulwark door and install safety chains / guardrails in place of door.
Action required: 705 - Other - as specified
Due 3 March 2006
Resolved 10 March 2006
Resolution: Attended vessel afloat dockside and found this item satisfactory this date.
Construction/Loadline › Structures › Scuttle
Issued 3 March 2006 Resolved
Repair all deck scuttle hatch gaskets and dogs to make these hatches watertight.
Action required: 705 - Other - as specified
Due 3 March 2006
Resolved 10 March 2006
Resolution: Attended vessel afloat dockside and found this item satisfactory this date.
Construction/Loadline › Structures › Door
Issued 3 March 2006 Resolved
Install weather-stripping around all 4 sides of engine room door to make weather tight.
Action required: 705 - Other - as specified
Due 3 March 2006
Resolved 10 March 2006
Resolution: Attended vessel afloat dockside and found this item satisfactory this date.
Construction/Loadline › Structures › Door
Issued 3 March 2006 Resolved
Repair engine room door so that it closes and latches properly.
Action required: 705 - Other - as specified
Due 3 March 2006
Resolved 10 March 2006
Resolution: Attended vessel afloat dockside and found this item satisfactory this date.
Construction/Loadline › Penetrations › Pipe Flange
Issued 3 March 2006 Resolved
Repair cable penetrations in galley / snack bar concession deck to make watertight.
Action required: 705 - Other - as specified
Due 3 March 2006
Resolved 10 March 2006
Resolution: Attended vessel afloat dockside and found this item satisfactory this date.
Construction/Loadline › Structures › Manhole
Issued 3 March 2006 Resolved
Repair or fabricate a new hatch cover for under galley void space to make this watertight and latchable.
Action required: 705 - Other - as specified
Due 3 March 2006
Resolved 10 March 2006
Resolution: Attended vessel afloat dockside and found this item satisfactory this date.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 3 March 2006 Resolved
Repack both propeller shafts.
Action required: 705 - Other - as specified
Due 3 March 2006
Resolved 10 March 2006
Resolution: Attended vessel afloat dockside and found this item satisfactory this date.
Construction/Loadline › Structures › Ventilators
Issued 3 March 2006 Resolved
Install ball check vent heads or blind over the steering gear compartment vent head and both vent heads for lazarette.
Action required: 705 - Other - as specified
Due 3 March 2006
Resolved 10 March 2006
Resolution: Attended vessel afloat dockside and found this item satisfactory this date.
Engineering › Bilge Water Management System › Pump
Issued 3 March 2006 Resolved
Perform an operational test of all bilge alarms and bilge pumping systems.
Action required: 705 - Other - as specified
Due 3 March 2006
Resolved 10 March 2006
Resolution: Attended vessel afloat dockside and found this item satisfactory this date.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 3 March 2006 Resolved
Provide a valid certificate of documentation for the vessel.
Action required: 705 - Other - as specified
Due 3 March 2006
Resolved 10 March 2006
Resolution: Received satisfactory attestation from VDOC this vessel DOC is valid this date and being processed for new ownership.
Communications › Radio Communications › EPIRB
Issued 17 May 2004 Resolved
REPLACE EPIRB HYDROSTATIC RELEASE.
Action required: 705 - Other - as specified
Due 1 June 2004
Resolved 17 May 2004
Resolution: HYDROSTATIC RELEASE REPLACED.
Lifesaving › Buoyant Apparatus
Issued 17 May 2004 Resolved
REPLACE HYDROSTATIC RELEASE FOR BA HOLD DOWN. LEGACY COMPONENT DESC: HYDROSTATIC RELEASE
Action required: 705 - Other - as specified
Due 1 June 2004
Resolved 1 June 2004
Resolution: RELEASE REPLACED.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 17 May 2004 Resolved
PROVIDE WASTE MANAGEMENT PLAN.
Action required: 705 - Other - as specified
Due 1 June 2004
Resolved 1 June 2004
Resolution: PLAN PROVIDED.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 17 May 2004 Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS.
Action required: 705 - Other - as specified
Due 1 June 2004
Resolved 1 June 2004
Resolution: SERVICE COMPLETED.
Lifesaving › Hand Flares › Quantity
Issued 17 May 2004 Resolved
PROVIDE 6 RED AND 6 ORANGE SMOKE FLARES AS REQUIRED.
Action required: 705 - Other - as specified
Due 1 June 2004
Resolved 17 May 2004
Resolution: FLARES PROVIDED.
Operations/Management › Drills/Instruction
Issued 13 November 2002 Resolved
CONDUCT UNDERWAY MAN OVERBOARD AND FIRE DRILLS. LEGACY COMPONENT DESC: Man Overboard Recovery
Action required: 705 - Other - as specified
Due 30 June 2003
Resolved 30 July 2003
Resolution: DRILLS CONDUCTED.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 13 November 2002 Resolved
CONDUCT UNDERWAY VESSEL MACHINERY AND OPERATING SYSTEM TESTS.
Action required: 705 - Other - as specified
Due 30 June 2003
Resolved 30 July 2003
Resolution: ALL UNDERWAY TESTS SAT.
Electrical › Electrical Distribution System (service)
Issued 13 November 2002 Resolved
INSTALL ELECTRICAL MATTING IN FRONT OF SWITCHBOARD IN THE ENGINEROOM. LEGACY COMPONENT DESC: Non-conducting Deck Covering
Action required: 705 - Other - as specified
Due 30 June 2003
Resolved 30 July 2003
Resolution: MATTING INSTALLED.
Navigation › Collision/Grounding Avoidance
Issued 13 November 2002 Resolved
REPAIR ANCHOR LIGHT. LEGACY COMPONENT DESC: Navigation Lights
Action required: 705 - Other - as specified
Due 30 June 2003
Resolved 30 July 2003
Resolution: ANCHOR LIGHT REPAIRED.
Lifesaving › Lifebuoys
Issued 13 November 2002 Resolved
INSTALL RETROREFLECTIVE TAPE ON RING BUOY ON THE PORT SIDE UPPER DECK. LEGACY COMPONENT DESC: Markings (ship name/port)
Action required: 705 - Other - as specified
Due 30 June 2003
Resolved 30 July 2003
Resolution: RETRO TAPE INSTALLED ON RING BUOY.
Lifesaving
Issued 6 November 2001 Resolved
CONDUCT MAN OVERBOARD AND FIRE DRILLS AT THE BEGINNING OF THE OPERATING SEASON.
Condition: Unknown
Due 30 June 2002
Resolved 1 July 2002
Resolution: DRILLS COMPLETED SAT.
Lifesaving
Issued 2 June 1998 Resolved
Within the next 30 days, conduct underway drills to the satisfaction of theattending Marine Inspector.
Condition: Unknown
Due 6 July 1998
Resolved 14 August 1998
Construction/Loadline
Issued 14 November 1996 Resolved
PROPERLY REPAIR PIN HOLE IN FORWARD BULKHEAD OF THE ENGINE ROOM.
Condition: Unknown
Due 21 September 2015
Resolved 21 September 2015
Electrical
Issued 14 November 1996 Resolved
TIGHTEN LOOSE WIRE ON 3-71 GENERATOR SET.
Condition: Unknown
Due 21 September 2015
Resolved 21 September 2015
Construction/Loadline
Issued 14 November 1996 Resolved
FREE UP FROZEN CHECK VALVE IN BILGE SUCTION LINE FOR MSD SPACE.
Condition: Unknown
Due 21 September 2015
Resolved 21 September 2015
Lifesaving
Issued 14 November 1996 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE CONDUCT UNDERWAY FIRE, ABANDON SHIP AND MAN OVERBOARD DRILLS.
Condition: Unknown
Due 21 September 2015
Resolved 21 September 2015
Lifesaving
Issued 14 November 1996 Resolved
POST VESSEL'S STATION BILL.
Condition: Unknown
Due 21 September 2015
Resolved 21 September 2015
Engineering
Issued 14 November 1996 Resolved
RENEW PORT ENGINE FLEXIBLE FUEL LINE.
Condition: Unknown
Due 21 September 2015
Resolved 21 September 2015
Construction/Loadline
Issued 8 August 1996 Resolved
PRIOR TO THE CARRIAGE OPF PASSENGERS, MAKE THE VESSEL EXTERIOR HULL AVAILABLE FOR EXAMINATION DUE TO GROUNDING.
Condition: Unknown
Due 8 August 1996
Resolved 14 August 1996
Lifesaving
Issued 21 November 1995 Resolved
RENEW DEFECTIVE WATER LIGHT FOR BUOYANT APPARATUS ON UPPER DECK.
Condition: Unknown
Due 21 September 2015
Resolved 21 September 2015
Fire Fighting
Issued 21 November 1995 Resolved
REWIRE BILGE/FIRE PUMP AND PROVIDE PROPER GUARD.
Condition: Unknown
Due 21 September 2015
Resolved 21 September 2015
Lifesaving
Issued 21 November 1995 Resolved
CONDUCT FIRE AND BOAT DRILLS PRIOR TO THE 1996 OPERATING SEASON.
Condition: Unknown
Due 21 September 2015
Resolved 21 September 2015
Construction/Loadline
Issued 21 November 1995 Resolved
ADJUST BILGE STRAINER IN STEERING COMPARTMENT.
Condition: Unknown
Due 21 September 2015
Resolved 21 September 2015
Engineering
Issued 21 November 1995 Resolved
RENEW FRAYED AIR COMPRESSOR HOSE ON THE STBD MAIN ENGINE.
Condition: Unknown
Due 21 September 2015
Resolved 21 September 2015
Accommodation/Occupational Safety
Issued 21 November 1995 Resolved
LABEL MEANS OF ESCAPE FROM THE ENGINE ROOM.
Condition: Unknown
Due 21 September 2015
Resolved 21 September 2015
Construction/Loadline
Issued 5 May 1995 Resolved
REPLACE BILGE STRAINER TO BILGE PIPING IN THE #2 VOID SPACE.
Condition: Unknown
Due 21 September 2015
Resolved 21 September 2015
Lifesaving
Issued 5 May 1995 Resolved
CONDUCT FIRE AND BOAT DRILLS IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 21 September 2015
Resolved 21 September 2015
Accommodation/Occupational Safety
Issued 25 May 1994 Resolved
PROVIDE PRESSURE RATING OR BUILDER'S DATA PLATE FOR SANITARY FLUSH PRESSURETANK.
Condition: Unknown
Due 30 June 1994
Resolved 7 July 1994
Engineering
Issued 25 May 1994 Resolved
MOUNT OIL TEMP GAGE FOR PORT MAIN ENGINE.
Condition: Unknown
Due 30 June 1994
Resolved 14 July 1994
Lifesaving
Issued 25 May 1994 Resolved
COMDUCT EMERGENCY DRILLS IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 12 July 1994
Resolved 12 July 1994
Engineering
Issued 25 May 1994 Resolved
INSTALL GUARDS FOR ALTERNATOR BELTS TO P&S MAIN ENGINES.
Condition: Unknown
Due 30 June 1994
Resolved 14 July 1994
Accommodation/Occupational Safety
Issued 25 May 1994 Resolved
INSTALL PRESSURE RELIEF VALVE FOR SANITARY PRESSURE TANK.
Condition: Unknown
Due 30 June 1994
Resolved 7 July 1994
Accommodation/Occupational Safety
Issued 25 May 1994 Resolved
MARK ENGINE ROOM EMERGENCY ESCAPE "EMERGENCY ESCAPE-KEEP CLEAR"
Condition: Unknown
Due 12 July 1994
Resolved 12 July 1994
Construction/Loadline
Issued 25 May 1994 Resolved
INSTALL EXAUST VENT DUCTS TO BILGE BELOW DECK PLATES.
Condition: Unknown
Due 30 June 1994
Resolved 14 July 1994
Documentation
Issued 25 May 1994 Resolved
VESSEL WAS NOT PROPERLY MARKED WITH NAME OF VESSEL ON BOW OR STERN.
Condition: Unknown
Due 30 June 1994
Resolved 7 July 1994
Accommodation/Occupational Safety
Issued 25 May 1994 Resolved
NEW FRESH WATER PRESSURE TANK NOT MARKED WITH ASME APPROVAL. PROVE ASME APPROVAL OR RENEW SAME.
Condition: Unknown
Due 30 June 1994
Resolved 7 July 1994
Lifesaving
Issued 3 June 1992 Resolved
Conduct drills in presence of a CG Marine Inspector.
Condition: Unknown
Due 21 September 2015
Resolved 21 September 2015
Accommodation/Occupational Safety
Issued 25 November 1986 Resolved
UNTIL SUCH TIME AS FIXED SEATING IS REINSTALLED THE TOTAL NUMBER OF PASSEN-GERS ALLOWED IS RESTRICTED TO 395.
Condition: Unknown
Due 21 September 2015
Resolved 21 September 2015

Casualty record · 2

16 July 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4086122
25 August 2015Routine · role: Involved in a Marine Casualty · activity 5228709
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.