RANGER is a 1971 passenger vessel (inspected). The Coast Guard has recorded 11 inspections since 2016, most recently in May 2021, along with 25 deficiencies — 13 with no resolution recorded —, 2 operational controls, 2 with no removal date recorded and 2 casualty investigations between 2011 and 2015.

Records from 2011 to 2021. Most recent: inspection, 25 May 2021.

Built
1971
Last inspected
25 May 2021
Documentation
Valid · documentation file of 10 August 2026
Controls
2 with no removal date recorded

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 May 2021
…past their stated due date10
Operational controls 2 with no removal date recorded
Years with a record 6 calendar years (2016–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD3855
Flag
UNITED STATES
Maury page id
psix-46907

Documentation record

Registered dimensions (L × B × D)79.9 ft × 27.2 ft × 8.7 ft
Registered tonnagegross 99 / net 71
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWARREN, RI, UNITED STATES · built 1971
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portALCATRAZ ISLAND, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
71 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 11

25 May 2021 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7207247
9 October 2020 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7074780
18 September 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6815325
6 November 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6574638
18 June 2018 Examination of Repairs · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6447973
6 June 2018 Drydock Extension
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6436241
28 November 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6314403
2 November 2017 Annual Inspection · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6299791
2 November 2016 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6040832
1 September 2016 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5973834
13 January 2016 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5796596

Deficiency record · 25

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 October 2020 No resolution recorded
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel did not complete drydock examination by due date. 46 CFR 176.600(c)(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 October 2020 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 April 2020 No resolution recorded
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Vessel has had outstanding deficiencies for over 7 months pending from its annual inspection on August 18th, 2019. Clear open defs prior to operations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 April 2020 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 September 2019 No resolution recorded
The two required fixed power bilge pumps shall be self-priming and shall each be by different sources of power. Vessel's electrical fire and bilge pump required manual priming. Prove proper operation of electrical fire and bilge pump without manual priming. 46 CFR 182-25-10(a)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 September 2019 No resolution recorded
Inspection of each life jacket. Many of the vessel's life jackets have corroded metal fittings rendering them difficult to don. Prove proper operation of life jackets.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 September 2019 No resolution recorded
Life jackets must be stored in convenient places distributed throughout accommodation spaces. Life jackets are stored above the stairwell. These life jackets are not readily accessible and need to be relocated.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 18 September 2019 No resolution recorded
Each hatch exposed to the weather must be watertight. Hatch to void #3 is currently secured using a piece of wood. Prove hatch complies with 171.124. 46 CFR 171.124
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2019 — due date passed with no resolution recorded
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 18 September 2019 No resolution recorded
Penetrations and openings in watertight bulkheads must have means to make them watertight. Sink drain flows to void #3. Provide means to make sink drain watertight. 46 CFR 171.114
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2019 — due date passed with no resolution recorded
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 18 September 2019 Resolved
Except as otherwise provided in this section, machinery and fuel tank spaces shall be separated from accommodation spaces by watertight and or vapor tight bulkheads of double diagonal wood, marine plywood, steel plate or equivalent. Holes leading from the engine room to the ADA restroom violate vapor tight boundaries. Holes leading from the engine room to the main deck passenger area violate watertight boundaries.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2019
Resolved 17 March 2020
Resolution: Verified that holes had been patched.
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 18 September 2019 No resolution recorded
Exhaust piping shall be led to the point of escape with a minimum number of bends or elbows. MIs on board observed visually with with a gas detector an exhaust leak coming from the starboard M/E's inboard exhaust discharge line. Fix exhaust leak.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2019 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 September 2019 No resolution recorded
Each lighting fixture and lampholder must be fixed. Corrosion has caused the P/S light adjacent the maneuvering station to be loose. Secure the lighting fixture.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2019 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 September 2019 No resolution recorded
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use. Grab lines on vessel's BAs are tightly gathered, rendering them difficult to be used in case of an emergency. Stow grab lines so they are ready for immediate use.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2019 — due date passed with no resolution recorded
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 18 September 2019 No resolution recorded
The discharge ends of vent pipes shall terminate on the hull exterior. Corrosion in fuel tank vent piping has caused holes flowing to passenger areas. Fix fuel tank vent piping.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2019 — due date passed with no resolution recorded
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 18 September 2019 No resolution recorded
Spaces containing machinery shall be fitted with at least two ducts to furnish natural or mechanical supply and exhaust ventilation. Corrosion in engine room ventilation has caused holes flowing to passenger areas. Fix engine room ventilation piping.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2019 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 September 2019 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041. Vessel's first aid kit was expired. First aid kit was replaced.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 18 September 2019
Resolved 18 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 November 2018 Resolved
Each major generator shall be fitted with a nameplate of corrosion-resistant material. Generator #1 was missing its nameplate. 46 CFR 183.10-5(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 November 2018
Resolved 6 November 2018
Resolution: Vessel rep produced new nameplates with manufacturer specs and posted onto generator.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 2 November 2017 Resolved
Prove proper operation of lighting in engine room. 46CFR183.432(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 28 November 2017
Resolution: Fixed and proved proper operation of emergency lighting in the engine.
Construction/Loadline › Structures › Superstructure
Issued 2 November 2017 Resolved
Repair holes on main deck in bulkheads (scattered throughout). 46CFR176.25-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2018
Resolved 22 March 2019
Resolution: Repaired in 2018 Drydock
Electrical › Electric Supply System (service) › Battery Installation
Issued 1 September 2016 Resolved
24V battery installation under pilothouse unsecured. Secure batteries from shifting. 46 CFR 183.05-20
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 September 2016
Resolved 13 September 2016
Resolution: Secured batteries from shifting.
Electrical › Electric Supply System (service) › Battery Installation
Issued 1 September 2016 No resolution recorded
Submit plans to OCMI detailing 24V system under pilothouse to include; load calculations, over current protection, and wire sizing. 46 CFR 176.700
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 November 2016 — due date passed with no resolution recorded
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 1 September 2016 Resolved
04 ring buoys inspected missing required lifeline around 01 ring buoy. Provide lifeline around body of ring bouy. 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2016
Resolved 1 September 2016
Resolution: Provided appropriate lifeline IAW 46 CFR 180.70
Construction/Loadline › Hull › Longitudinal Frame
Issued 1 September 2016 Resolved
Stiffeners on longitudinal in steering gear compartment severely corroded and painted over. Submit repair proposal to OCMI. 46 CFR 176.404
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 22 March 2019
Construction/Loadline › Hull › Transverse Frame
Issued 1 September 2016 Resolved
Cracked welds on port frames between stiffeners 3 & 4 in #4 aft space. Submit repair proposal to OCMI. 46 CFR 176.404
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 22 March 2019
Electrical › Electrical Distribution System (service) › Junction Box
Issued 1 September 2016 Resolved
Junction in overhead in steering space spliced incorrectly at fan connection. Make correct connections in junction box. 46 CFR 183.340
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 October 2016
Resolved 7 October 2016
Resolution: Placed spliced wire in junction box.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 1 September 2016 Resolved
Wire spliced incorrectly in 32V charger system in pilot house. Make correct connections in junction box. 46 CFR 183.340
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 October 2016
Resolved 7 October 2016
Resolution: Placed spliced wire in junction box.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 September 2016 Resolved
Identified discrepancy between COI and stability letter concerning Max persons. Vessel may operate with a max of 459 persons onboard.
Action required: 705 - Other - as specified
Due 1 September 2016
Resolved 1 September 2016
Resolution: Ensured COI and stability letter have the same max persons listed.

Casualty record · 2

16 July 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4086122
25 August 2015Routine · role: Involved in a Marine Casualty · activity 5228709
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.