Inspection history · 31
19 February 2026
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8312973
10 December 2025
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8281772
3 November 2025
Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8259642
27 October 2025
Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8259061
12 November 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8033537
13 August 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7980783
13 August 2024
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7980811
12 June 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7933671
12 June 2024
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7934217
24 February 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7870228
14 December 2023
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7839241
4 December 2023
Deficiency Check · Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7833206
21 September 2023
Administrative Inspection · Internal Structural Exam · Drydock Extension
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7796068
9 August 2023
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7764333
7 September 2022
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7553456
6 July 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7499215
6 July 2022
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7513113
25 January 2022
Drydock Exam · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7382619
20 September 2021
Drydock Extension
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7316409
8 September 2021
COI Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7302570
12 February 2021
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7138916
26 January 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7130724
8 December 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7108055
8 July 2019
Annual Inspection · In-Service Inspection · Drydock Exam · Administrative Inspection · Deficiency Check · Plan Review (Other than "T")
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6742259
11 September 2018
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6532093
12 April 2018
Administrative Inspection · In-Service Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6390676
7 November 2017
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6302850
2 November 2016
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6040857
8 September 2016
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5995734
4 May 2016
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5879570
27 January 2016
Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5805750
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 3 November 2025
Resolved
A vessel must comply with the applicable requirements for any radio .... installations, including the requirements for a station license and installation certificates to be issued by the FCC, as set forth in 47 CFR part 80. Radio Station Authorization document has Radio Service listed incorrectly as "Ship Recreational or Voluntarily". 46 CFR 121.502
47 CFR 80.405
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2025
Resolved 24 December 2025
Resolution: Received new Station License of correct type and new Bridge to Bridge and Safety Radiotelephony certs to reflect call sign change.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 November 2025
Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Plastic waste can found at snack bar/galley. 46 CFR 116.405(i)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2025
Resolved 15 November 2025
Resolution: Received photo evidence of replacement trash can that is of non-combustible material.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 November 2025
Resolved
Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray. Battery box near port gen did
not prevent shifting of batteries. 46 CFR 120.350
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2025
Resolved 15 November 2025
Resolution: Received photo evidence of adequate bracing material fitted in battery box.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 November 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Dead-end wiring found at Op-station. 46 CFR 120.200
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 November 2025
Resolution: Dead-end wire properly secured during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 November 2025
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Ring Life Buoy located outside of wheelhouse on port side to has several lacerations through the outer layer of protective reinforcement rendering it unserviceable. 46 CFR 115.808(b) / 46 CFR 117.70
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 3 November 2025
Resolution: Replaced life buoy with a compliant one during inspection.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 12 November 2024
Resolved
The marine inspector shall examine and test the main and auxiliary steering apparatus to the extent necessary that its condition is satisfactory and that it is fit for the service intended. MI observed minor water leak at rudder post when vessel is underway. 46 CFR 176.25-35(Old T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2024
Resolved 26 November 2024
Resolution: Received video of steering gear operating u/w.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 November 2024
Resolved
An inspection for renewal of a certificate of inspection shall include an inspection of the structure, machinery
and equipment. The inspection shall be such as to insure that the vessel, as regards the...fire extinguishing equipment...is in satisfactory condition and fit for the service for which it is intended. MI observed minor leak to intake pipe fitting at the fire pump. 46 CFR 176.05-10(Old T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2024
Resolved 26 November 2024
Resolution: Received video of piping while fire pump running.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 12 November 2024
Resolved
Lighting fixtures shall be constructed in accordance with the requirements of Underwriters' Laboratories,
Inc. Standard for Marine Type Electric Lighting Fixtures, Subject 595...MI observed lighting fixture in lazarette on starboard side without bulb or cover. 46 CFR 183.10-25(l)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2024
Resolved 26 November 2024
Resolution: Received picture of installed bulb and cover.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 9 August 2023
Resolved
All vessels except non-self-propelled vessels shall be provided with suitable steering apparatus. Port rudder stock packing seal was leaking water into the lazarette. Make repairs and remove excess of water in lazarette.
46 CFR 182.30-1(a) "Old T"
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 August 2023
Resolution: Tightened rudder stock packing.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 August 2023
Resolved
Carbon dioxide warning signs. Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked. Space storing the CO2 cylinders was not marked at the entrance.
46 CFR 122.612(i)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 9 August 2023
Resolution: Installed proper signage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 September 2022
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including operational test of the means provided for pumping bilges. Bilge strainer in fuel tank void is not of a suitable material.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2022
Resolved 6 October 2022
Resolution: Replaced bilge suction with metal strainers
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 September 2021
Resolved
Each life jacket carried on board the vessel must be marked IAW 122.604 of this chapter. MI found 98 Adult and 13 child life jackets that had worn reflective tape. 01 adult life jacket had quarter-size whole in shell, MI observed disposal of life jacket. Vessel is required to have life jackets on board that meet number of passengers to match COI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 September 2021
Resolved 9 September 2021
Resolution: Vessel Rep provided photographs of retro-reflective tape added to PFD and bought new Child PFD.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 September 2021
Resolved
Penetrations in watertight bulkhead must be as high and inboard as practicable and made watertight. MI observed penetrations in the subdividsion bulkhead from fuel tank space to aft of engine room. Crew corrected on the spot.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Resolved 8 September 2021
Resolution: penetration corrected on the spot to satisfaction of MI.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 12 February 2021
Resolved
Stowage. If the buoyant apparatus (BA) does not have a painter attachment fitting, a means for attaching the painter must be provided by a wire or line which encircles the body of the device and will not slip off. BA painter rigging found at two connections to be fastened to the grab line vice the BA, and in two places through the lifeline festoon vice the painter attachment. 46 CFR 117.137(d); 160.010-4.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 February 2021
Resolution: Vessel representative provided photos of properly rigged floats.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 8 July 2019
Resolved
Charts and nautical publications. As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Vsl uses only electronic charts, which indicated 2013-17 upload and updates.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 October 2019
Resolved 29 October 2019
Resolution: Vsl uses online chart update. 2nd Captain logged onto service website, and able to update onboard charts to 28 SEP 2019 corrections within 5 minutes.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 8 July 2019
Resolved
If the buoyant apparatus does not have a painter attachment fitting, a means for attaching the painter must be provided by a wire or line which encircles the body of the device. Buoyant apparatus must have a fitting with an inside diameter of at least 50 mm (2 in.) for the attachment of a painter. The painter between #3 and #4 BA was fastened via the grab line, vice the manufacturer pendant, another painter, between #2 and #3 BA was fastened via the grab line fitting.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 October 2019
Resolved 29 October 2019
Resolution: Vsl moved the painter from grab line to the painter fitting. Due to the arrangement, vsl called [name withheld] discussed approval for using the grab line fitting vice painter fitting (as proof that grab line fittings also encircle the BA).
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 September 2018
Resolved
Fized fire system distribution piping is not the appropriate size adjacent to CO2 tank. Piping is required to extend 2 inches beyond last orifice as per 46 CFR 118.410d(2). Vsl rep will determine with Fire technician a course of action.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2018
Resolved 28 September 2018
Resolution: Provided appropriate piping size and capping to the satisfaction of the Marine Inspector.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 8 September 2016
Resolved
Waterlight on lifefloat inoperable, replace battery. 46 CFR 180.175
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2016
Resolved 8 September 2016
Resolution: Provided new battery in waterlight. Waterlight operable.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 8 September 2016
Resolved
Condemned 10 lifejackets. 501 lifejackets total onboard. Limited to 501 total persons onboard. 46 CFR 180.71
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2016
Resolved 13 September 2016
Resolution: Provided 07 additional lifejackets, total persons onboard raised to 508 IAW COI.