Records from 2016 to 2025. Most recent: inspection, 30 December 2025.
Inspection history · 42
30 December 2025
Administrative Inspection · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8288310
20 June 2025
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8162493
5 December 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8042561
5 December 2024
Administrative Inspection · PSC B · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8043516
27 October 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8024231
19 August 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7983734
16 July 2024
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7959888
16 July 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7961390
15 July 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7958531
6 July 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7950489
13 June 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7933943
3 June 2024
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7923249
2 December 2023
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7832612
6 November 2023
PSC B · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7819216
26 April 2023
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7675209
2 February 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7631094
8 November 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7591340
30 September 2022
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7569070
2 June 2022
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7465939
3 March 2022
Ballast Water Examination · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7404926
27 August 2021
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7297390
16 July 2021
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7258110
2 June 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7212982
13 April 2021
Deficiency Check · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7173762
6 January 2021
PSC B · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7119791
26 December 2020
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7116179
1 July 2020
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6992806
16 June 2020
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6977011
5 June 2020
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6968151
7 May 2020
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6949734
28 October 2019
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6842119
16 May 2019
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6685435
18 April 2019
NPV Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6664569
22 October 2018
Ballast Water Examination · PII Safety Exam · Administrative Inspection · Deficiency Check · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6565555
2 May 2018
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6403903
25 April 2018
Administrative Inspection · Ballast Water Examination · PI Safety Exam · ISPS I Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6399291
18 October 2017
ISPS II Exam · Administrative Inspection · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6290224
17 April 2017
ISPS II Exam · Deficiency Check · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6123641
8 November 2016
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6037458
13 October 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6021510
29 March 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5842528
27 January 2016
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5804793
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 30 December 2025
Resolved
In sleeping rooms, an electrical reading lamp shall be installed at the head of each berth. PSCO observed 02 reading lights in the AB state rooms not working.
46 USC 70002
16bc
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 January 2026
Resolved 20 January 2026
Resolution: Received documentation from flag attesting to the correction of this deficiency.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 June 2025
Resolved
... Fire protection systems and fire-fighting systems and appliances shall be properly tested and inspected.
PSCO observed 13 pins missing from CO2 nozzles in forward CO2 space.
SOLAS(04) Ch. II-2/Reg.14.1.2
Code 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 20 June 2025
Resolution: Vessel crew immediately places pins in CO2 nozzles where they were missing.
05 - Radio Communications › N/A - No Subsystem › INMARSAT ship earth station
Issued 5 December 2024
Resolved
On ships engaged in voyages in sea areas A3 and A4, the availability shall be ensured by using such methods as duplication of equipment...
PSCOs observed an error on one of the INMARSAT-C systems, rendering it inoperable.
74SOLAS(20)IV/15.7
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 December 2024
Resolved 17 January 2025
Resolution: Received flag documentation attesting to repairs.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 June 2024
Resolved
Guard rails fitted on superstructures and freeboard decks shall have at least three courses. The opening below the lowest course of the guardrails shall not exceed 230 mm. PSCOs observed a missing bottom rail on the forward stbd side, a broken top raid midship on the stbd side, and multiple vertical stanchions broken on the stbd side.
ICLL (88 Proto) 25(3)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 June 2024
Resolution: Received documentation from class attesting to the repair of the guard rails.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 6 November 2023
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company.
In meeting these requirements, the company should ensure that: records of these activities are maintained.
PSCO's observed the vessels crew did not create a maintenance record in accordance with their safety management system when a fuel oil leak was discovered on board.
74 SOLAS (20) IX/3.1
ISM CODE Part A/10.2.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2023
Resolution: Received flag report attesting to repairs
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 November 2023
Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board.
PSCOs observed a oil fuel leak emanating from a fuel supply pipe between the fuel pump and fuel injector. Additionally, PSCOs observed an oily water mixture in the aft engine room bilge well.
74 SOLAS (97) II-2/15.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2023
Resolution: Received flag report attesting to repairs
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 6 November 2023
Resolved
Hydraulic power-operated steering gear shall be provided with the following: arrangements to maintain the cleanliness of the hydraulic fluid taking into consideration the type and design of the hydraulic system.
During the operational test, PSCOs observed a leak emanating from the No. 1 steering gear pump.
74 SOLAS (04) II-1/29.12.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2023
Resolution: Received flag report attesting to repairs
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 6 November 2023
Resolved
Except as provided in paragraph (3) of this regulation, ventilator openings shall be provided with weathertight closing appliances. PSCOs observed missing gasket material on the port side separator room ventilator opening.
ICLL 66 Annex I/19.4
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 6 November 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 30 September 2022
Resolved
Guard rails or bulwarks shall be fitted around all exposed decks. PSCO's observed 03 guardrails on the port side of the vesssel not properly afixed to the stanchions on the exposed main deck of the vessel.
ICLL 66 Annex 1 Reg. 25(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2022
Resolved 8 October 2022
Resolution: Vessel satisfactorily repaired the guardrails and provided pictures.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 June 2021
Resolved
Main and auxiliary machinery essential for the propulsion and safety of the ship shall be provided with effective means for its operation and control...PSCO's received a report of loss of propulsion approximately 10NM offshore due to main engine failure. The vessel required dead-ship tow and must submit report attesting to cause of the failure and completion of repairs.
74 SOLAS (04) II-1/31.1
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2021
Resolution: PSCO's attended vessel to verify. Vessel also submitted class survey accepted by flag.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 13 April 2021
Resolved
Oil filtering equipment referred to in paragraph 1 of this regulation shall be of a design approved by the administration and shall be such as will ensure that any oily mixture discharged into the sea after passing through the system has an oil content of less than 15 ppm. The 3 way valve is not functioning properly. valve is unable to close as intended.
MARPOL(17 Cons.) Annex I/ Reg.14.6
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 April 2021
Resolution: Oil content meter and three-way valve replaced satisfactory
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 13 April 2021
Resolved
Any required fixed fire detection and fire alarm system with manually operated call points shall be capable of immediate operation at all times. Fire control panel alerts continuous alarm in engine room. Crew unable to clear alarm.
74 SSOLAS(97 Cons.) II-2/31.1.1
Action required: 10 - Deficiency Rectified
Due 13 April 2021
Resolved 13 April 2021
Resolution: Crew identified the issue with the continuous alarm and were able to clear it from the control panel
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 6 January 2021
Resolved
Each emergency generating set arranged to be automatically started shall be equipped with starting devices approved by the administration with a stored energy capability of at least three consecutive starts. the emergency generator failed due to faulty battery charger.74SOLAS(04)II-1/44.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2021
Resolution: Received email from vessel agent containing an invoice for two new battery chargers along with pictures of them installed. Team was sent to the vessel and witnessed starting of emergency generator on both circuits.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 26 December 2020
Resolved
Any required fixed fire detection and fire alarm system with manually operated call points shall be capable of immediate operation at all times. Fire control panel alerts continuous alarm in zone 1. Crew is unable to clear it. 74SOLAS(97 CONS) II-2/13.1.1 17bc
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 December 2020
Resolution: PSCOs received attestation letter from Flag addressing both deficiencies have been resolved. PSCOs attended the vessel tested both smoke detectors from Zone 1 satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 26 December 2020
Resolved
In addtition to complying with the specific provisions for fire integrity of bulheads...the minimum fire integrity of bulkheads and decks shall be as prescribed in tables 44.1 and 44.2. PSCO observed penetration in the bulkhead separating the [name withheld] accomodation space and the corridor. 74SOLAS(97 CONS) II-2/44.1 16bc
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 December 2020
Resolution: PSCOs received attestation letter from Flag addressing both deficiencies have been resolved. PSCOs attended the vessel, observed penetration on "B" class boundary patched.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 16 June 2020
Resolved
The ring, lines and letters shall be painted in white or yellow on a dark background...the marks shall be plainly visible. PSCO's observed that the initial markings for the classification society were difficult to read due to the old classification society initials have not been repainted to contrast with current classification society. ICLL 66 Annex I/8
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2020
Resolved 18 June 2020
Resolution: Vessel painted white the correct lettering for the classification society on the hull.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 June 2020
Resolved
Ships shall be provided with hoses the number...of which shall be to the satisfaction of the administration. PSCO's discovered a missing fire hose near the forward locker. SOLAS 74 (97 Cons) II-2/ 4.7.2
Action required: 10 - Deficiency Rectified
Due 16 June 2020
Resolved 16 June 2020
Resolution: Vessel Agent brought a new hose and assembly to the vessel to replace the missing hose.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 June 2020
Resolved
Each hose shall be provided with a nozzle and necessary couplings. Hoses specified in this chapter shall...be kept ready for use. PSCO's observed the fire hose on the port bridge wing and nozzle were in poor condition. The hose has several pin hole leaks and the nozzle could not change fog positions and leaked. SOLAS 74 (97 CONS) 11-2/4.7.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2020
Resolved 18 June 2020
Resolution: Hoses and nozzles were replaced. In good working condition now.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 June 2020
Resolved
Doors required to be self-closing shall not be fitted with hold back hooks. PSCO's observed the class A self-closing door between the galley and the pantry has been fitted with a hold back hook. SOLAS 74 (97 Cons) 11-2/47.2
Action required: 10 - Deficiency Rectified
Due 16 June 2020
Resolved 16 June 2020
Resolution: PSCO's witness the chief engineer removing the hold back hook and wall mount assembly from the bulkhead.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 May 2019
Resolved
Each enclosed space entry and rescue drill shall include checking and use of instruments for measuring the atmosphere in enclosed spaces. Ships onboard atmospheric testing instrument was one month out of calibration. Crew was unfamiliar with intervals required for calibration. 74SOLAS(14Cons.) III/19.3.6.2.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2019
Resolved 31 May 2019
Resolution: Received flag report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 18 April 2019
Resolved
THE CONDITION OF THE SHIP SHALL BE MAINTAINED TO ENSURE THAT THE SHIP WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER. FIRE PUMP GUAGE IS INOPERABLE DUE TO MISSING NEEDLE. 74 SOLAS (14 CONS) I/11(A)
Action required: 10 - Deficiency Rectified
Due 18 April 2019
Resolved 18 April 2019
Resolution: GAUGE WAS REPLACED WITH A SPARE AND TESTED SUCCESSFULLY
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 18 April 2019
Resolved
MACHINERY AND ASSOCIATED PIPING AND FITTINGS SHALL BE OF A CONSTRUCTION ADEQUATE FOR THEIR SERVICE AND SHALL BE SO INSTALLED TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ONBOARD. EMERGENCY DIESEL GENERATOR HAS AN EXHAUST LEAK, CAUSING CO2 SPIKE IN SPACE. 74 SOLAS (2014 CONS.) II-1/ 26.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2019
Resolved 16 May 2019
Resolution: Flange was repaired and tested for leaks. No leaks detected. See attached report of corrections.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 18 April 2019
Resolved
FALLS USED IN LAUNCHING SHALL BE RENEWED AT INTERVALS NOT MORE THAN 5 YEARS. RESCUE BOAT DAVIT FALLS WERE REPLACED MARCH 2014. 74 SOLAS (2014 CONS.) III/20.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2019
Resolved 16 May 2019
Resolution: Wire rope was renewed. See attached report of corrections.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 22 October 2018
Resolved
1299- Water/Weather tight Conditions- Load Lines Shall be permanently marked on the side of the ship to the satisfaction of the administration. PSCO's observed Load Lines marked inconsistently with the issued certificate. -ICLL(66) ANNEX I Reg. 8
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 22 October 2018
Resolved 25 October 2018
Resolution: Loadline matching loadline certificate was permanently affixed to the hull. Recieved attestation from class.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 October 2018
Resolved
0999- Working and Living Conditions- All electrical cables and wiring external to equipment shall be installed as to not impair their original flame retarding properties. PSCO's observed step up and down transformer in provision store compartment with multiple modifications to the wiring. The ships 220V system was spliced with 110V wiring to a refrigerator. -74SOLAS(2004 Cons.) II-I/45.5.2
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 22 October 2018
Resolved 25 October 2018
Resolution: Vessel installed proper wiring connected to transformer for 110V output. Recieved attestation from class.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 28 April 2018
Resolved
9900 - No person may use any equipment for transfer operations unless the vessel tests the equipment. The annual static liquid pressure test of the transfer pipe system for the vessel was not tested at 1.5 times the maximum allowable working pressure. 33CFR156.170(c)(4) Prior to bunkering U.S.
Action required: 703 - Prior to bunkering operations
Resolved 2 May 2018
Resolution: Annual static liquid pressure test was completed.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 28 April 2018
Resolved
9900 - Transfer proceudres must be permanently posted or available at a place where the proceudures can be easily seen and used by members of crew when engaged in transfer operations. No proceudures for transfer operations could be made available and easily seen during transfer operations. 33CFR155.740(c) Prior to bunkering U.S.
Action required: 703 - Prior to bunkering operations
Resolved 2 May 2018
Resolution: Transfer procedures were provided for each side of the vessel, near PIC transfer points (including the engine room).
Lifesaving › Inflatable Liferafts › Container Construction
Issued 17 April 2017
Resolved
The liferaft shall be packed in a container that is constructed as to withstand hard wear under conditions encountered at sea. The Stbd side liferaft container is cracked in 02 places. 74 SOLAS (97) III/39.7.1.1
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 April 2017
Resolution: New Liferaft was placed on vessel.
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 17 April 2017
Resolved
All ships of 500GT and upwards shall have a Gyro Compass bearing repeater to take bearings over an arc at the horizon of 360 degrees. The brindge wing Port side gyro-compass bearing repeater is inoperable. 74 SOLAS (14 Con) V/19.2.5.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 April 2017
Resolution: Gyro compass repeater was fixed and tested to the satisfaction of the attending surveyor and CG examiner.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 October 2016
Resolved
1299 - Other Load Lines - Efficient guard rails shall be fitted. Guard rail on forward port side was wasted all the way through at the weld of the post. ILLC 60/Annex1/25.2
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 October 2016
Resolved 13 October 2016
Resolution: Rail was sufficiently welded and corrected on the spot.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 October 2016
Resolved
0899 - Other accident prevention - All electrical installations shall be such that the safety of the crew will be ensured. Exposed conduit box and broken light in cargo hold were discovered. 74 SOLAS 04 con. II-1/40.3
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 October 2016
Resolved 13 October 2016
Resolution: Conduit box cover plate was installed and light in cargo hold was replaced.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 13 October 2016
Resolved
1730 - Oily-water separating equip - The condition of the ship and its equipment shall be maintained to conform with present regulations to ensure that the ship shall remain fit to proceed to sea. Oily water separator overboard discharge pipe was factured and leaking into the bilge. 74 SOLAS 04 con. I/11
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 8 November 2016
Resolution: Fractured pipe for overboard discharge replaced and no leaking found.
Construction/Loadline › Markings › Load Line Mark
Issued 29 March 2016
Resolved
1220 - The ring lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. STBD-side loadline mark was not in a contrasting color to the hull. Ref: ICLL 66 (88) Reg 8
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2016
Resolved 29 March 2016
Resolution: Loadline mark painted with contrasting color to hull.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 29 March 2016
Resolved
2120 - Every ship of 400 GT and above shall be provided with a Garbage Record Book. Each completed page of the Garbage Record Book shall be signed by the master of the ship. The pages of the Garbage Record Book have not been signed since April 2015.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2016
Resolved 29 March 2016
Resolution: Master signed records IAW MARPOL regulations.