PEPIN is a 1972 towing vessel. The Coast Guard has recorded 22 inspections since 1992, most recently in July 2026, along with 41 deficiencies — 17 with no resolution recorded — and 3 casualty investigations between 2003 and 2024.

Records from 1992 to 2026. Most recent: inspection, 29 July 2026.

Built
1972
Last inspected
29 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 29 July 2026
…with no type recorded9
…past their stated due date15
Operational controls None recorded without a removal date
Years with a record 14 calendar years (1992–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI5169
113244
Flag
UNITED STATES
Maury page id
psix-113244

Documentation record

Registered dimensions (L × B × D)54.0 ft × 22.0 ft × 7.9 ft
Registered tonnagegross 76 / net 51
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF BOAT BUILDING CORP. · BILOXI, MS, UNITED STATES · built 1972
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMIAMI, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 April 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it51 - Regulatory (Subpart C or D), Net Ton
76 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 7

Inspection history · 22

29 July 2026 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8449757
23 September 2025 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8115923
5 May 2025 Deficiency Check · Drydock Exam · Administrative Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8115920
27 January 2025 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8070103
20 August 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7971929
16 July 2024 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7961390
21 July 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7748169
25 April 2022 Administrative Inspection · Initial Certification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7439033
2 August 2016 DAPI Audit
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6033999
25 July 2016 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5952554
19 January 2016 Deficiency Check · Industry Initiated Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5799579
15 October 2009 MTSA Verification · Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3614978
14 September 2006 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2778922
27 June 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2692903
23 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978434
7 July 2003 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1839876
28 February 2003 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1769829
27 June 2002 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1637687
23 December 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1637667
29 January 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 507173
5 March 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 131330
6 April 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 524006

Deficiency record · 41

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 July 2026 Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must:(1) Be maintained to ensure proper operation. Operator reported water in the STBD MDE engine.
Action required: 60 - Rectify deficiencies prior to movement
Due 11 August 2026
Resolved 10 August 2026
Resolution: Received overhaul techical report, and attended vessel for operation test. Deficiency cleared.
01 - Certificates & Documentation › 011 - Ships Certificates › Pollution Prevention by Noxious Liquid Sub in Bulk
Issued 23 September 2025 No resolution recorded
Each towing vessel must carry at least one appropriately-sized lifejacket, approved under approval series 160.002, 160.005, 160.055, 160.155, 160.176, or 160.255 for each person on board. The vessel is restricted to three persons onboard until they get a fourth lifejacket on the vessel.
Action required: 705 - Other - as specified
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 23 September 2025 No resolution recorded
A towing vessel of at least 26 feet, but less than 79 feet, in length must carry a minimum of two lifebuoys located on opposite sides of the vessel where personnel are normally present. Lifebuoys are not installed at locations where personnel are normally present.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2025 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › Pollution Prevention by Noxious Liquid Sub in Bulk
Issued 23 September 2025 No resolution recorded
Each lifejacket must be marked: With Type I retro-reflective material approved under approval series 164.018. The arrangement of the retro-reflective material must meet IMO Resolution A.658(16) (incorporated by reference, see § 136.112 of this subchapter). The retro-reflective tape of all 3 of the lifejackets onboard needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2025 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › Pollution Prevention by Noxious Liquid Sub in Bulk
Issued 23 September 2025 No resolution recorded
Lifejackets must have the following attachments and fittings: Each lifejacket must have a lifejacket light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the lifejacket. One of the lifejacket lights was not working and needs to be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2025 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 September 2025 No resolution recorded
Each watertight door and watertight hatch must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR—KEEP CLOSED” or “WATERTIGHT HATCH—KEEP CLOSED”. The two forward watertight hatches need to be labeled.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2025 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 September 2025 No resolution recorded
The hull of each documented vessel must be marked as required by part 67 of this chapter. The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. The hailing port is missing from the stern.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2025 — due date passed with no resolution recorded
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 23 September 2025 No resolution recorded
No later than July 22, 2019, the owner or managing operator must implement a health and safety plan. The health and safety plan must document compliance with this part and include recordkeeping procedures. health and safety is missing the following: procedures for an unsafe condition and procedures for equipment usage.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2025 — due date passed with no resolution recorded
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 23 September 2025 No resolution recorded
A towing vessel must carry adequate and up-to-date charts, maps, and nautical publications for the intended voyage, including: “U.S. Coast Pilot” or similar publication. Vessel needs new and up to date U.S. Coast Pilot.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2025 — due date passed with no resolution recorded
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 September 2025 No resolution recorded
Each towing vessel must be equipped with navigation lights, shapes, and sound signals in accordance with the International Regulations for Prevention of Collisions at Sea (COLREGS) or 33 CFR part 84 as appropriate to its area of operation. The anchor light needs to be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2025 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 September 2025 No resolution recorded
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. The wire in the cable on the mast corroded and exposed and needs to be properly insulated to prevent an electrical hazard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2025 — due date passed with no resolution recorded
08 - Alarms › N/A - No Subsystem › General alarm
Issued 23 September 2025 No resolution recorded
Each towing vessel must be fitted with a general alarm that: Is activated at each operating station and can notify persons onboard in the event of an emergency. There needs to be a general alarm at the aft operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2025 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 23 September 2025 No resolution recorded
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. This is not meant to restrict access to towing equipment such as winches, drums, towing gear or steering compartment equipment necessary for the operation of the vessel. There is an exposed rotating belt hazard on the starboard side aft engine air compressor.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2025 — due date passed with no resolution recorded
14 - Pollution Prevention › 143 - MARPOL Annex III › Marking and labelling
Issued 23 September 2025 Resolved
All suction valves necessary for the operation of the fire main must be kept in the open position or capable of operation from the same place where the remote fire pump control is located. When testing fixed fire pump, it was observed that fire main sea suction valve was closed. CORRECTED ON THE SPOT.
Action required: 10 - Deficiency Rectified
Resolved 23 September 2025
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 September 2025 No resolution recorded
Portable and semi-portable fire extinguishers must be inspected, maintained, and tested in accordance with the inspection, maintenance procedures, and hydrostatic pressure tests required by Chapters 7 and 8 of NFPA 10, Standard for Portable Fire Extinguishers. The spare fire extinguisher in the crew mess/galley needs to be placed in an approved bracket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2025 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 September 2025 No resolution recorded
The connections of flexible cable plugs and socket outlets must be designed to prevent unintended separation. The potable water pump was found to be electrically connected using a flexible cable plug that is not designed to prevent unintended separation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2025 — due date passed with no resolution recorded
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 23 September 2025 No resolution recorded
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks that provide strength and support equivalent to fixed rails. Railings need to be installed on both the forward and aft sections of the vessel in the areas not containing the interior grab rails on the house of the vessel or the aft step deck prior to the vessel completing its next drydock in July 2027.
Action required: 705 - Other - as specified
Due 31 July 2027
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 September 2025 No resolution recorded
The connections of flexible cable plugs and socket outlets must be designed to prevent unintended separation. Permanently installed extension cord found installed in engine room overhead that is not designed to prevent unintended separation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2025 — due date passed with no resolution recorded
08 - Alarms › N/A - No Subsystem › General alarm
Issued 23 September 2025 No resolution recorded
Alarms required by 46 CFR 143.203(a) must: (1) Be visible and audible at each operating station. The alarm located at the operating station may be a summary alarm; if the alarm at the operating station is a summary alarm, the specific alarm condition must be indicated at the machinery or bilge location; (2) Have a means to test actuation at each operating station or have a continuous self-monitoring alarm system which actuates if an alarm point fails or becomes disabled; (3) Continue until they are acknowledged; and (4) Not interfere with night vision at the operating station. The aft operating station on this vessel does not have the required alarms installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2025 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 20 August 2024 Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. Vessel does not have a means for closing openings in ventilation intake funnel on PORT and STBD funnel.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2024
Resolved 4 September 2024
Resolution: Ventilation closure device installed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 August 2024 Resolved
The officer in charge of a navigational watch must conduct a navigation assessment for the intended route and operations prior to getting underway. Vessel does not complete navigation assessments prior to getting underway.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2024
Resolved 29 August 2024
Resolution: Vessel created proper navigation assessment.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 August 2024 Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. Breaker panel in the mess deck is not properly labeled for individual breakers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2024
Resolved 29 August 2024
Resolution: Breaker panel properly labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 August 2024 Resolved
Electrical systems and equipment must function properly and minimize shock hazards. Breaker panel in engine room is missing required blank within electrical panel.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2024
Resolved 29 August 2024
Resolution: Proper blanks installed in breaker panel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 August 2024 Resolved
Lifebuoys must have the following attachments and fittings. (2)At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light approved under approval series 161.010 or 161.110. STBD side lifebuoy floating light did not work.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2024
Resolved 29 August 2024
Resolution: Life float light replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 20 August 2024 Resolved
Each watertight door and watertight hatch must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR—KEEP CLOSED” or “WATERTIGHT HATCH—KEEP CLOSED”. All water tight hatches on the main deck are missing proper labeling.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2024
Resolved 4 September 2024
Resolution: water tight hatches on main deck, properly labeled.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 20 August 2024 Resolved
A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised. Both PORT and STBD aft deck hatch's have wasted sealing edge and will not properly seal to prevent water ingress.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 January 2025
Resolution: New man holes installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 August 2024 Resolved
The following systems must be equipped with gauges at the machinery location: (1) Main engine lubricating oil pressure and main engine RPM and (3) Auxiliary generator engine lubricating oil pressure and auxiliary generator engine RPM. Main engines and auxiliary generators do not have RPM gauges installed in the machinery space.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2024
Resolved 4 September 2024
Resolution: New gauges installed for RPM.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 August 2024 Resolved
Portable and semi-portable fire extinguishers must be inspected, maintained, and tested in accordance with the inspection, maintenance procedures, and hydrostatic pressure tests required by Chapters 7 and 8 of NFPA 10. (ii) Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Crew is not conducting and documenting monthly fire extinguisher inspections per NFPA 10 and galley fire extinguisher was found with tamper seal missing.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 20 August 2024
Resolution: Discussed with operator how to complete and document monthly extinguisher checks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 August 2024 Resolved
All pressure vessels must have the Maximum Allowable Working Pressure (MAWP) indicated by a stamp, nameplate, or other means visible to the crew. Air compressor pressure vessel has no markings visible to indicate MAWP.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2024
Resolved 29 August 2024
Resolution: MAWP nameplate relocated to be visible.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 August 2024 Resolved
46 143.260 (e)Each remote valve control must be marked in clearly legible letters, at least 25 millimeters (1 inch) high, indicating the purpose of the valve and the way to operate it. Valves are not labeled with operating instructions.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2024
Resolved 29 August 2024
Resolution: valves properly labled for operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 July 2023 Resolved
46 CFR 143.275: There must be an installed or portable bilge pump for emergency dewatering. Renew bilge system and perform testing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 August 2023
Resolved 2 August 2023
Resolution: Repaired bilge pump breaker switch
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 July 2023 Resolved
46 CFR 142.220: Each towing vessel must be maintained and operated so as to minimize fire hazards. Empty and clean bilges in engine room and fwd compartment taking care not to inadvertently discharge into the waterway.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 August 2023
Resolved 2 August 2023
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 July 2023 Resolved
46 CFR 142.325(c): Each life float and rigid buoyant apparatus must be fitted with a... electric floating water light.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 2 August 2023
Resolved 2 August 2023
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 21 July 2023 Resolved
46 CFR 142.325(a)(2): A fixed fire pump must be capable of being energized remotely ... and at the pump. Renew means of local starting at the fire pump.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2023
Resolved 8 August 2023
Resolution: Fire pump local start/stop switch installed, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 July 2023 Resolved
46 CFR 143.205(c)(1): Propulsion machinery including shafting must be maintained to ensure proper operation. Renew or replace starboard side shaft packing to eliminate leakage.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2023
Resolved 2 August 2023
Resolution: Shaft packing replaced, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 12 July 2022 Resolved
Each life float must be fitted with a life line, pendants, painter, and floating electric water light approved under approval series 161.010. Provide painter and floating water light. 46 CFR 141.325(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2022
Resolved 12 July 2022
Resolution: Life float painter and water light provided.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 12 July 2022 Resolved
Survival craft must be marked in accordance with the requirements of 199.176 and 199.178 of this chapter. Properly mark the life float and associated paddles. 46 CFR 141.315
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2022
Resolved 12 July 2022
Resolution: All properly marked.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 12 July 2022 Resolved
The float-free link is designed to be broken by the buoyant force of the life float or buoyant apparatus so that the float or apparatus breaks free of a vessel that sinks in water deeper than the length of the painter. Provide properly sized weak link. 46 CFR 160.073
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2022
Resolved 12 July 2022
Resolution: Properly sized weak link provided.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 July 2022 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists. High bilge alarm reads low l/o pressure on the bridge. Local indication in the engine room is correct. Prove proper operation of the bridge alarm. 46 CFR 143.230
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2022
Resolved 13 July 2022
Resolution: Video evidence of proper operation received.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 July 2022 Resolved
Towing vessels 65 feet or less may meet the requirements in 33 CFR 183.810 or paragraph (a) of this section. Replace the broken light cover on the stbd running light, and replace the lens on the mast head light. 46 CFR 143.415
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2022
Resolved 2 August 2022
Resolution: Lens replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 July 2022 Resolved
Machinery must be designed and maintained to provide for safe operation of the towing vessel and for the safety of persons on board. Indicators of exhaust leaks were found. Make permanent repairs to the starboard main engine exhaust. 46 CFR 143.205
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2022
Resolved 2 August 2022
Resolution: Exhaust leaks repaired.

Casualty record · 3

28 February 2003Routine · role: Involved in a Marine Casualty · activity 1769829
25 July 2016Routine · role: Involved in a Marine Casualty · activity 5952554
16 July 2024Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 7961390
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

PADDY CROSBY (2003). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.