Records from 1994 to 2026. Most recent: inspection, 18 February 2026.
Documentation record
Registered dimensions (L × B × D)72.0 ft × 26.0 ft × 10.7 ft
Registered tonnagegross 170 / net 116
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderOFFSHORE SHIPBUILDERS INC · HOUMA LA, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 9 February 2026 · expires 28 February 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it170 - Regulatory (Subpart C or D), Gross Ton
116 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDE7330MMSI 367391930 · active · compulsorily equipped · granted 6 November 2018, expires 23 January 2029
WDA7743MMSI 369110000 · cancelled · compulsorily equipped · granted 12 April 2002, cancelled 9 August 2011
WCZ4953MMSI not assigned · cancelled · compulsorily equipped · granted 13 September 1999, cancelled 30 April 2004 · licensed under a name not among this hull’s recorded names (not shown)
WCY9874MMSI 338440000 · expired · compulsorily equipped · granted 9 April 1999, cancelled 13 June 2009 · licensed under a name not among this hull’s recorded names (not shown)
WCY4524MMSI not assigned · expired · compulsorily equipped · granted 11 June 1998, cancelled 16 August 2008 · licensed under a name not among this hull’s recorded names (not shown)
WCR2501MMSI not assigned · expired · compulsorily equipped · granted 1 May 1995, cancelled 2 July 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s
MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 27
18 February 2026
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8324141
16 May 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8137250
13 May 2025
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8134751
18 September 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8004938
8 April 2024
MTSA Verification · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7892239
7 April 2024
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7893525
22 June 2023
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7720307
24 May 2022
Initial Certification · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7465215
20 June 2013
MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4630330
20 March 2013
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 4553816
20 March 2013
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4554630
6 June 2012
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4335744
18 May 2012
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4315027
17 April 2011
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3991691
10 May 2010
MTSA Verification · Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3735705
12 January 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3663771
21 August 2006
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2755309
10 January 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2272053
22 August 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2176633
22 August 2004
Uninspected Other · Examination of Repairs · MTSA Verification · Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2181504
26 April 2004
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2053192
22 April 2004
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2053111
1 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1968471
7 February 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1747252
10 June 1999
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1511129
11 December 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 120998
8 July 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 368466
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 24 May 2022
Resolved
Each towing vessel operating in oceans and coastwise service must have a line throwing appliance approved under approval series 160.040
Vessel did not have proper line throwing device and additional equipment.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 23 July 2022
Resolved 24 June 2022
Resolution: Obtained complement of line-throwing appliances and auxiliary equipment.
Construction/Loadline › Hull › Bottom Plating
Issued 27 August 2004
Resolved
Make temporary repairs to holed sections of hull and provide repair proposal to MSO Port Arthur, TX to include permanent repairs. See COTP Order 2004-159.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 August 2004
Resolution: Replaced bottom plate 5'' x 6'' port fuel tank and 6'' x 10'' portside FWD
Electrical › Lighting (service) › Lighting Fixture
Issued 22 August 2004
Resolved
Bulbs missing from masthead
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2004
Resolved 30 August 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 August 2004
Resolved
Steering senser, bare wires
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2004
Resolved 30 August 2004
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 22 August 2004
Resolved
Cover for breaker
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2004
Resolved 30 August 2004
Electrical › Electrical Distribution System (service) › Panelboard
Issued 22 August 2004
Resolved
Electrical panel cover missing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2004
Resolved 30 August 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 August 2004
Resolved
Secure sagging wires in engine room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 10 May 2010
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 22 August 2004
Resolved
Secure EXT. in engine room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 10 May 2010
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 22 August 2004
Resolved
Clean up engine room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 10 May 2010
Operations/Management › Cargo Transfer/Lightering › Conducted IAW Vessel Transfer Procedures
Issued 22 August 2004
Resolved
A description of each transfer system on vessel
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 10 May 2010
Operations/Management › Drills/Instruction › Safety Orientation
Issued 22 August 2004
Resolved
Noise hazard, post in engine room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 10 May 2010
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 22 August 2004
Resolved
List of each products transfer
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 10 May 2010
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 22 August 2004
Resolved
# of persons required to be on duty during transfer ops.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 10 May 2010
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 22 August 2004
Resolved
Placard for type III missing, need to have a placard
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 10 May 2010