Records from 2016 to 2025. Most recent: inspection, 3 September 2025.
Documentation record
Registered dimensions (L × B × D)139.2 ft × 110.0 ft × 12.5 ft
Registered tonnagegross 199 / net 135
ITC dimensions (L × B × D)139.2 ft × 110.0 ft × 12.5 ft
ITC tonnagegross 1,799 / net 539
BuilderBOCONCO INC · BAYOU LA BATRE, AL, UNITED STATES · built 2009
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 19 November 2025 · expires 30 November 2026
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it199 - Regulatory (Subpart C or D), Gross Ton
1799 - Convention (Subpart B), Gross Ton
135 - Regulatory (Subpart C or D), Net Ton
539 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 17
3 September 2025
Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8225899
15 April 2024
Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7895740
31 October 2023
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7818349
8 June 2023
MARPOL Annex VI Survey · MTSA/ISPS Verification · MARPOL Annex I Examination · COI Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7700944
28 April 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7439722
11 April 2022
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7428497
23 March 2022
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7417089
21 September 2021
Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7316985
27 May 2021
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7208353
5 November 2020
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7090486
2 April 2019
Annual Inspection · Drydock Exam · MTSA Verification · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6654473
11 February 2019
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6623580
19 June 2018
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6449704
5 March 2018
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6366314
10 August 2017
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6236705
16 March 2017
Hull Examination · Administrative Inspection · Deficiency Check · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6105848
1 June 2016
MTSA/ISPS Verification · MARPOL Annex V Examination · MARPOL Annex IV Survey · MARPOL Annex I Examination · Annual Inspection · MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5894441
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 3 September 2025
Resolved
Each propeller on a rescue boat must be fitted with a propeller guard with a maximum opening of 3in. on all sides on which a person is likely to be exposed. The rescue boat did not have a propeller guard.
46 CFR 133.135(a)
46 CFR 160.156-7(11)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 October 2025
Resolved 5 September 2025
Resolution: A prop guard for the rescue boat was purchased and installed.
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 3 September 2025
Resolved
The garbage record book along with receipts obtained from reception facilities shall be kept on board and readily available for inspection. Completed pages within the record book were not signed by the Master, and receipts from discharge to a reception facilities or vessels were not being obtained/ kept onboard. Receipts should be in the format specified in MARPOL Annex V appendix II - MEPC.1/Circ.834/Rev.1
MARPOL 73/78(2020 cons) Annex V / Reg. 10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 October 2025
Resolved 5 September 2025
Resolution: The Master was educated on the requirement to review/sign completed GRB pages, and the company generated a standard receipt that will be used for discharge to reception facilities.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 April 2022
Resolved
If a grounded distribution system is provided, there must be only one connection to ground; e-gen switchboard ground detection gauge displayed a 2 amp ground.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2022
Resolved 29 April 2022
Resolution: Vessel located ground fault on electric motor and has invoice for new motor.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 28 April 2022
Resolved
Every ship of 400 gross tons and above shall maintain an Oil Record Book per the Oil Record Book instructions; Oil Record Book quantities were not consistently recorded. [name withheld], [name withheld], and Vessel Rep.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 28 April 2022
Resolution: Master, Chief engineer and Vessel Rep informed of requirement for consistent quantities to be logged.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 April 2022
Resolved
Annual inspection's scope is to include fire hazards; discovered fuel small fuel leak at the starboard jacking thruster and small hydraulic leaks from hydraulic lines on both port and starboard rudders, rectified on the spot.
46 CFR 126.510(a)
46 CFR 126.430
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 28 April 2022
Resolution: Connections tightened, leaks cleaned to the satisfaction of the MI.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 21 September 2021
Resolved
Disposable hydrostatic release past expiration date.
Action required: 10 - Deficiency Rectified
Due 21 September 2021
Resolved 21 September 2021
Resolution: Purchased and installed new hydrostatic release
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 September 2021
Resolved
Jacking gear hydraulic low level alarm not producing an audible alarm
Action required: 10 - Deficiency Rectified
Due 21 October 2021
Resolved 21 September 2021
Resolution: Wiring re-installed and operation proved to CGMI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 21 September 2021
Resolved
Port MDE high temp alarm inoperable
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2021
Resolved 1 October 2021
Resolution: installed and tested new alarm
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 November 2020
Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2020
Resolved 5 November 2020
Resolution: Conducted annual inspection
Construction/Loadline › Hull › Hull Plating
Issued 17 March 2017
Resolved
Section of aft leg rack damaged from previous event including pinions.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 June 2018
Resolution: Completed repairs to aft leg & rack. All tests complete.