Records from 2003 to 2024. Most recent: inspection, 5 November 2024.
Documentation record
Registered dimensions (L × B × D)65.0 ft × 24.0 ft × 6.0 ft
Registered tonnagegross 62 / net 50
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCHIASSON WELDING SERVICE · LAROSE, LA, UNITED STATES · built 1997
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBELLE CHASE, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 February 2026 · expires 28 February 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it62 - Simplified, Gross Ton
50 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 20
5 November 2024
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8029988
29 March 2024
Internal Structural Exam · COI Inspection · Examination of Repairs · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7887057
25 July 2023
Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7735912
20 March 2023
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7647603
11 August 2022
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7444698
3 August 2021
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7256267
28 September 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7071716
24 September 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7065408
1 June 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7062538
20 June 2019
Initial Certification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6719982
22 August 2016
Type not recorded
No type recorded · Station Venice · USCG Heartland District (CGD-H) · Activity 5980153
28 August 2015
Deficiency Check · Industry Initiated Exam · MARPOL
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5746301
31 October 2013
Spot Check (Safety)
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4747092
20 August 2012
Industry Initiated Exam · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4446707
28 April 2011
Type not recorded
No type recorded · Station Venice · USCG Heartland District (CGD-H) · Activity 3997752
31 March 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3443523
14 March 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3443488
7 July 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2125123
4 March 2004
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2022729
7 February 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1747252
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 10 June 2024
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space. No emergency lighting in crew accommodation spaces. Provide sufficient illumination for safe egress.
46 CFR 143.410(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2024
Resolved 10 June 2024
Resolution: Received pictures proof of installation and operation of e-lgihting in the P-way out side of the crew accomodations. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 July 2023
Resolved
Both generator windings were excessively soiled with debris.
Action required: 705 - Other - as specified
Due 1 August 2023
Resolved 26 July 2023
Resolution: Both Generators were disassembled, cleaned of all soil and debris, reassembled, and tested for proper operation
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 25 July 2023
Resolved
Fixed fire pump was unable to reach 50 PSI.
Action required: 705 - Other - as specified
Due 1 August 2023
Resolved 26 July 2023
Resolution: Troubleshot the fire pump and found faulty gauge. Installed new calibrated gauge and tested for proper function. Test sat, pump holds pressure at 50 psi.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 July 2023
Resolved
Exhaust leaks were noted on the main engines.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2023
Resolved 27 July 2023
Resolution: Vessel crew removed lagging, no exhaust was identified, area was cleaned and tested. Lagging was replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 July 2023
Resolved
Flammable liquids found outside suitable container in the engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2023
Resolved 26 July 2023
Resolution: All flammable items were removed from vessel and stored in shoreside container and will remain there until new approved vessel flammable locker arrives.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 25 July 2023
Resolved
Bilges were soiled with pooled oil.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2023
Resolved 26 July 2023
Resolution: All deck plates were removed, all oily waste was removed from bilges and cleaned of oily residue. Bilges dried and deck plates reinstalled.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 25 July 2023
Resolved
Grease fitting on watertight doors were found painted, preventing proper maintenance of the closure devices.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2023
Resolved 27 July 2023
Resolution: New zerk fittings installed and lubricated in accordance with manufacturers recommendations. Watertight doors tested; test sat.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 28 September 2020
Resolved
Sub M vessels are required to maintain approved type work vests. Found all crew work vests of an approved type not compatible with the vessel. Replace work vests.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2020
Resolved 5 October 2020
Resolution: Submitted photo evidence of newly purchased approved work vests for all crew.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 September 2020
Resolved
Paint lockers require a dedicated 40-B fire extinguisher. Found 10-B:C extinguisher for paint locker. Replace with appropriate size extinguisher.
Action required: 10 - Deficiency Rectified
Due 12 October 2020
Resolved 28 September 2020
Resolution: Installed a servicable spare 40-B portable extinguisher in close proximity to the paint locker.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 September 2020
Resolved
Fire extinguishing equipment must be suitable for route and service. Found 160-B semi-portable extinguisher mounted in a location where the hose would not reach the engine room. Relocate 160-B.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2020
Resolved 5 October 2020
Resolution: Photos submitted showing the 160-B relocated to acceptable location for engine room servicing.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 September 2020
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Found electrical splice open to atmosphere. Remove or enclose wiring.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2020
Resolved 5 October 2020
Resolution: Photo submitted showing electrical connection in a suitble enclosure.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 September 2020
Resolved
A Towing vessel may not be operated without having onboard a valid COI. Vessel is outside its inspection interval requirement, vessel cannot operate until inspection is completed.
46 CFR 136.200(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2020
Resolution: Completed COI inspection. Sector New Orleans to issue COI documentation.