Inspection history · 57
17 July 2012
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4381532
25 June 2012
PII Safety Exam · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4356135
26 February 2010
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3686770
10 August 2007
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3023532
2 April 2007
Administrative Inspection
Administrative · Activities Europe · Activity 2948329
26 October 2006
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2808526
1 August 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2818788
1 May 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2638025
21 April 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2637837
18 April 2006
MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2624069
10 January 2005
Hull Examination · MTSA/ISPS Verification · Construction Oversight · Internal Structural Exam
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2272345
14 June 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2098293
14 June 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2098342
28 April 2004
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2054369
22 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1972291
22 April 2003
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1778659
6 February 2002
MARPOL Annex I Examination · Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1483900
4 February 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1600961
2 January 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1479223
2 August 2001
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1070993
19 June 2001
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1067498
21 May 2001
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1410565
5 May 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1049741
27 March 2000
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1386713
23 June 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1469273
16 June 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 811420
15 June 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1471346
11 December 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 120998
22 May 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1442609
12 May 1997
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1424390
9 September 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 948278
19 May 1996
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 187629
16 May 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1363676
28 April 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357243
21 February 1995
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1396256
19 May 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1382801
14 October 1993
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 963099
9 August 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1154272
2 August 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1157893
3 June 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467834
16 April 1993
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1429745
2 September 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1270337
21 July 1992
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1471944
7 April 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 949217
15 August 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 935478
5 June 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 935977
5 June 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 921687
5 June 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1234362
21 February 1990
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 926721
20 June 1989
MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 890862
20 June 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1345169
29 June 1988
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 898014
2 July 1987
COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1336706
10 November 1986
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1322399
16 April 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 984824
20 December 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278653
8 September 1981
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 966316
Fire Fighting › Fire Hoses › Condition
Issued 25 June 2012
Resolved
0720 - Fire Fighting Equipment - Vsl shall have operational fire hoses as per Vsl Fire Safety Plan. Several hoses failed during testing. Vsl required to replace broken hoses and test ALL hoses stored on deck. - PWSA
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2012
Resolution: USCG personnel witnessed satisfactory tests for all hoses stored on deck.
Fire Fighting › Fire Main › Condition
Issued 25 June 2012
Resolved
0725 - Fixed Fire Extinguishing Installation - Vsl shall have operable fire main. The fire main ruptured during testing producing large leakage. - PWSA
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2012
Resolution: Received Class Survey verifying repair.
Construction/Loadline › Markings › Load Line Mark
Issued 25 June 2012
Resolved
1220 - Freeboard Marks - Loadline marks shall be plainly visible, and painted in contrasting colors. Vsl loadline was not painted in contrasting colors. - ILL Annex I Regulation 8
Action required: 705 - Other - as specified
Due 25 July 2012
Resolved 16 July 2012
Resolution: Received Class Survey verifying repair.
Operations/Management › Vessel Safety Management › Resources and Personnel
Issued 25 June 2012
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2012
Resolution: MSU personnel verified manning requirements and compared mariners with their national licenses.
Operations/Management › Vessel Safety Management › Resources and Personnel
Issued 25 June 2012
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 25 July 2012
Resolved 24 July 2012
Resolution: MSU personnel received application for endorsement from VU for necessary crew members.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 6 February 2002
Resolved
EMERGENCY LIGHTING IWO DIVE QUARTERS NOT WORKING
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 March 2002
Resolved 15 March 2002
Resolution: REPAIRED
Lifesaving › Inflatable Liferafts › Markings
Issued 6 February 2002
Resolved
MISSING LIFERAFT LAUNCHING INSTRUCTIONS.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 14 March 2002
Resolved 15 March 2002
Resolution: INSTALLED
Fire Fighting › Fire Pumps
Issued 6 February 2002
Resolved
EMERGENCY FIRE PUMP DOES NOT SELF PRIME AND PROVIDE FULL PRESSURE. LEGACY COMPONENT DESC: Pressure
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 14 March 2002
Resolved 15 March 2002
Resolution: INSTALLED PRIMING LINE.
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 6 February 2002
Resolved
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 March 2002
Resolved 15 March 2002
Resolution: FABRICATED AND INSTALLED STANDARD DISCHARGE CONNECTION.
Engineering › Pressure Vessel › Relief Valve
Issued 6 February 2002
Resolved
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 March 2002
Resolved 15 March 2002
Resolution: INSTALLED.
Documentation
Issued 21 May 2001
Resolved
Prior to getting underway provide documentation of vessel having 06 lifeboatmen onboard.
Condition: Unknown
Due 22 May 2001
Resolved 23 May 2001
Electrical
Issued 21 May 2001
Resolved
Survey vessel and properly terminate all deadend wires.
Condition: Unknown
Due 5 July 2001
Resolved 5 July 2001
Lifesaving
Issued 21 May 2001
Resolved
Provide emergency lighting for embarkation of liferafts.
Condition: Unknown
Due 5 July 2001
Resolved 5 July 2001
Engineering
Issued 21 May 2001
Resolved
Stencil direction arrow with off showing direction to secure emergency fuelshutoffs.
Condition: Unknown
Due 5 July 2001
Resolved 5 July 2001
Deck/Cargo
Issued 27 March 2000
Resolved
PROVIDE CERTIFICATION FOR DECK CRANE. DO NOT OPERATE CRANE UNTIL CERTIFICATION RECORDS WITNESSED BY AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 27 April 2000
Resolved 11 April 2000
Electrical
Issued 27 March 2000
Resolved
DEMONSTRATE LOW LUB-OIL PRESSURE SHUT DOWN ON 05 GENERATORS.
Condition: Unknown
Due 27 April 2000
Resolved 11 April 2000
Documentation
Issued 22 May 1997
Resolved
PROVIDE CORRECTED COPIES OF FIRE & LIFESAVING PLAN.
Condition: Unknown
Due 27 June 1997
Resolved 8 August 1997
Accommodation/Occupational Safety
Issued 22 May 1997
Resolved
PROVIDE COPY OF ABS SURVEYOR'S REPORT REGARDING MODIFICATIONS TO TANKS/ ACCOMMODATIONS.
Condition: Unknown
Due 20 July 1997
Resolved 8 August 1997
Documentation
Issued 16 May 1996
Resolved
PROVIDE A SHIPBOARD OIL POLLUTION EMERGENCY PLAN (SOPEP) APPROVED FOR THIS VESSEL.
Condition: Unknown
Due 16 August 1996
Resolved 13 June 1996
Lifesaving
Issued 21 February 1995
Resolved
PLACE SAFETY NETTING AROUND VESSEL'S HELICOPTER DECK AS PER 46CFR108.235(e).
Condition: Unknown
Due 21 February 1995
Resolved 21 February 1995
Lifesaving
Issued 21 February 1995
Resolved
VESSEL'S HELICOPTER DECK IS TO BE MADE FREE OF VERTICAL PROJECTIONS WITHIN ITS MANEUVERING ZONE AS REQUIRED IN NVIC 9-81 PARAGRAPH 2(1)a & b and 46CFR108.235.
Condition: Unknown
Due 21 February 1995
Resolved 21 February 1995
Accommodation/Occupational Safety
Issued 21 February 1995
Resolved
PRIOR TO USING THE NEW LIVING QUARTERS, THEY MUST BE INSPECTED AND FOUND SATISFACTORY BY A U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 21 February 1995
Resolved 21 February 1995
Navigation
Issued 21 February 1995
Resolved
PERSON IN CHARGE IS TO ENSURE THE VESSEL'S RUNNING LIGHTS ARE IN ACCORDANCEWITH THE INTERNATIONAL REGULATIONS FOR PREVENTION OF COLLISIONS AT SEA, 1972 (72 COLREGS).
Condition: Unknown
Due 3 March 1995
Resolved 3 March 1995
Documentation
Issued 3 June 1993
Resolved
PROVIDE ONBOARD A DOCUMENT WITH CORRECT OWNERS ADDRESS.
Condition: Unknown
Due 3 June 1993
Resolved 3 June 1993
Construction/Loadline
Issued 16 April 1993
Resolved
PRIOR TO GETTING VESSEL UNDERWAY, RENEW 4" OVERBOARD DISCHARGE CHECK VALVE_x001C_FOR BILGE/BALLAST SYSTEM.
Condition: Unknown
Due 3 May 1993
Resolved 28 April 1993
Fire Fighting
Issued 21 July 1992
Resolved
PROVIDE TWO COMPLETE FIREMANS' OUTFITS TO BE LOCATED IN SEPARATE UNLOCKED LOCATIONS. VESSEL RESTRICTED TO OTHER THAN INTERNATIONAL VOYAGES.
Condition: Unknown
Due 21 August 1992
Resolved 2 September 1992
Deck/Cargo
Issued 16 April 1986
Resolved
PROVIDE COAST GUARD APPROVED DRAWINGS FOR INSTALLED OILY WATER SEPARATOR SYSTEM.
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986