Records from 2016 to 2026. Most recent: inspection, 21 January 2026.
Inspection history · 16
21 January 2026
COC-TVE Annual · PSC B · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8297748
17 January 2026
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8297714
23 January 2025
COC-TVE Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8065608
17 January 2025
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8065249
14 August 2023
PSC B · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7763077
21 September 2022
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7563298
8 September 2022
COC-TVE Annual · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7554097
12 August 2021
COC-TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7285031
15 June 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6977312
21 January 2020
COC-TVE Renew · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6891377
22 November 2017
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6323259
19 June 2017
COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6154474
18 April 2017
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6129783
19 March 2017
COE-Administrative
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6107377
30 November 2016
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6050022
25 May 2016
COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5886909
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 January 2026
Resolved
WHERE CABLES WHICH ARE INSTALLED IN HAZARDOUS AREAS INTRODUCE THE RISK OF FIRE AND EXPLOSION IN THE EVENT OF AN ELECTRICAL FAULT IN SUCH AREAS, SPECIAL PRECAUTIONS AGAINST SUCH RISKS SHALL BE TAKEN TO THE SATISFACTION OF THE ADMINSITRATION. PSCOS OBSERVED 02 DEAD END WIREWS IN THE CARGO PUMP ROOM.
74SOLAS(20)II-1/45.5.4
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 22 January 2026
Resolution: Received class documentation showing proper installation of explosion proof housing for the termination of the wires.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 January 2026
Resolved
ELECTRICAL INSTALLATIONS SHALL BE SUCH THAT THE SAFETY OF PASSENGERS, CREW, AND SHIP FROM ELECTRICAL HAZARDS WILL BE ENSURED. PSCOS OBSERVED AN UNAUTHORIZED SURGE PROTECTOR INSTALLED IN THE BACK OF THE CARGO CONTROL ROOM CONSOLE.
74SOLAS(20)II-1/40.1.3
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 21 January 2026
Resolution: FIXED ON THE SPOT BY REMOVING THE SURGE PROTECTOR AND AN OUTLET WAS ADDED UNDER THE SWITCHBOARD FOR PERMINENANT POWER REQUIREMENTS