MAURY USCG vessel records
← All vessels

ASP TREASURES

ASP TREASURES is a 2016 tank ship. The Coast Guard has recorded 16 inspections since 2016, most recently in January 2026, along with 2 deficiencies and 3 operational controls.

Records from 2016 to 2026. Most recent: inspection, 21 January 2026.

Built
2016
Last inspected
21 January 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 January 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9732242
1385472
Flag
PANAMA
Maury page id
psix-1385472

Documentation record

Tonnage as PSIX records it62659 - Convention (Subpart B), Gross Ton
35897 - Convention (Subpart B), Net Ton
195941 - Displacement, Metric Ton
115063 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SAN JACINTO Tank Ship · MISLE 1407345 · 22 November 2017 · activity 6323259

Inspection history · 16

21 January 2026 COC-TVE Annual · PSC B · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8297748
17 January 2026 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8297714
23 January 2025 COC-TVE Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8065608
17 January 2025 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8065249
14 August 2023 PSC B · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7763077
21 September 2022 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7563298
8 September 2022 COC-TVE Annual · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7554097
12 August 2021 COC-TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7285031
15 June 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6977312
21 January 2020 COC-TVE Renew · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6891377
22 November 2017 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6323259
19 June 2017 COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6154474
18 April 2017 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6129783
19 March 2017 COE-Administrative
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6107377
30 November 2016 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6050022
25 May 2016 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5886909

Deficiency record · 2

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 January 2026 Resolved
WHERE CABLES WHICH ARE INSTALLED IN HAZARDOUS AREAS INTRODUCE THE RISK OF FIRE AND EXPLOSION IN THE EVENT OF AN ELECTRICAL FAULT IN SUCH AREAS, SPECIAL PRECAUTIONS AGAINST SUCH RISKS SHALL BE TAKEN TO THE SATISFACTION OF THE ADMINSITRATION. PSCOS OBSERVED 02 DEAD END WIREWS IN THE CARGO PUMP ROOM. 74SOLAS(20)II-1/45.5.4
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 22 January 2026
Resolution: Received class documentation showing proper installation of explosion proof housing for the termination of the wires.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 January 2026 Resolved
ELECTRICAL INSTALLATIONS SHALL BE SUCH THAT THE SAFETY OF PASSENGERS, CREW, AND SHIP FROM ELECTRICAL HAZARDS WILL BE ENSURED. PSCOS OBSERVED AN UNAUTHORIZED SURGE PROTECTOR INSTALLED IN THE BACK OF THE CARGO CONTROL ROOM CONSOLE. 74SOLAS(20)II-1/40.1.3
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 21 January 2026
Resolution: FIXED ON THE SPOT BY REMOVING THE SURGE PROTECTOR AND AN OUTLET WAS ADDED UNDER THE SWITCHBOARD FOR PERMINENANT POWER REQUIREMENTS

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.