Records from 1994 to 2025. Most recent: inspection, 15 July 2025.
Documentation record
Registered dimensions (L × B × D)66.4 ft × 24.0 ft × 10.2 ft
Registered tonnagegross 158 / net 107
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderF B WALKER & SONS INC · PASCAGOULA, MS, UNITED STATES · built 1976
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portJEFFERSON CITY, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 February 2026 · expires 28 February 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it107 - Regulatory (Subpart C or D), Net Ton
158 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 17
15 July 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8136130
4 April 2025
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8104981
16 December 2024
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8048173
17 July 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7926381
7 November 2023
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7821640
18 July 2022
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7509928
14 March 2022
Administrative Inspection · Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7411531
14 March 2022
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7412900
27 February 2022
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7405374
28 July 2021
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7270683
12 April 2021
Initial Certification · Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7181526
20 June 2020
Damage Survey · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6981936
20 June 2020
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7001748
27 September 2012
Industry Initiated Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4451235
9 March 1995
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 659165
14 October 1994
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 371498
13 October 1994
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 139919
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 March 2022
Resolved
Machinery and electrical equipment must be designed and maintained to provide for safe operation of vessel. The steering system breakers trip when the vessel is steered hard causing a loss of control.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 March 2022
Resolution: Received email notification contaiing objective evidence sufficient to clear deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 August 2021
Resolved
Starboard main engine's ECM is OOC. Prove proper operation of engine.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 September 2021
Resolution: Repairs made, engine operated satisfactorily.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 August 2021
Resolved
A remote fuel shut off valve must be installed on fuel lines feeding engines. Remote operating cables are inoperative. Prove proper operation of remote fuel shutoff valves.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 September 2021
Resolution: Operating cables replaced, valves operated satisfactorily.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 August 2021
Resolved
The forward masthead light is inoperative. Prove proper operation of masthead light.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 September 2021
Resolution: Light assembly replaced and functioned normally.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 August 2021
Resolved
Fire detection panel has trouble alarm and, since silenced, fire alarm only indicates visible indication with no audible alarm. Prove proper operation of fire detection panel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 September 2021
Resolution: Fire detection panel repaired and operated normally.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 25 August 2021
Resolved
Prove ability to test all set points for required engine alarms.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 September 2021
Resolved 20 September 2021
Resolution: Tests conducted satisfactorily.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 August 2021
Resolved
Fuel tank vents are obstructed. Prove proper fuel tank venting.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 September 2021
Resolution: Obstruction removed and all is sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 25 August 2021
Resolved
Forward hold deck hatch is not watertight because of missing gasket. Replace gasket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 September 2021
Resolved 20 September 2021
Resolution: Gasket replaced, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 August 2021
Resolved
Electric heater in forward hold is not mounted. Mount heater securely.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 September 2021
Resolved 20 September 2021
Resolution: Heater installed sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 August 2021
Resolved
Securely mount electrical junction box in forward hold.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 September 2021
Resolved 20 September 2021
Resolution: Junction box mounted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 August 2021
Resolved
Portable fire extinguisher in forward hold is loose. Mount fire extinguisher in appropriate bracket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 September 2021
Resolved 20 September 2021
Resolution: Bracket mounted sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 25 August 2021
Resolved
Emergency lighting must be provided for all internal crew working and living spaces. Ensure all such spaces meet requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 September 2021
Resolved 20 September 2021
Resolution: Photo-luminescent tape installed around perifery of exits as allowed by reg. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 25 August 2021
Resolved
All three engine room water tight doors are missing dogs. Return doors to water tight condition.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 September 2021
Resolved 20 September 2021
Resolution: Repairs made as necessary.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 August 2021
Resolved
Both generator's windings are coated in oil residue. Trouble shoot and repair leaks as necessary and clean windings.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2021
Resolved 20 September 2021
Resolution: Generator windings cleaned and leaks repaired as necessary.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 July 2021
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the associated fleet that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no long be permitted to operate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 October 2021
Resolved 25 August 2021
Resolution: Issued Initial COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 June 2020
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protections against hazards to life, property, and environment. The vessel struck a dike causing damage to the starboard shaft/propeller. Make proper repairs and prove proper operation of the starboard running gear to the satisfaction of the attending USCG Marine Inspector.
Preliminary plan is to dry-dock vessel in the St. Louis area for repairs. Provide a transit plan to [email withheld] for review and approval prior to the vessel departing home-port.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 July 2020
Resolution: The deficiency was cleared to the satisfaction of a Coast Guard Marine Inspector.
Accommodation/Occupational Safety
Issued 14 October 1994
Resolved
MSD OVERBOARD DISCHARGE VALVE WAS IN THE OPEN POSITION ON A TYPE III SYSTEM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Navigation
Issued 14 October 1994
Resolved
VESSELS RADIO STATION LICENSE WAS EXPIRED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 November 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 14 October 1994
Resolved
RING BUOY DID NOT HAVE A COAST GUARD APPROVAL NUMBER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 October 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 14 October 1994
Resolved
VESSEL DID NOT HAVE AN OIL POLLUTION PLACARD POSTED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 October 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 14 October 1994
Resolved
VESSEL DID NOT HAVE A MARPOL PLACARD POSTED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 October 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 14 October 1994
Resolved
VESSEL HAD NO OIL TRANSFER PROCEDURES AND HAD A FUEL CAPACITY GREATER THAN 10,500 GALLONS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 October 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 14 October 1994
Resolved
VESSEL HAD NO INLAND NAVIGATION RULES ON BOARD.
Condition: Unknown
Due 30 October 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past