Records from 2017 to 2026. Most recent: inspection, 31 March 2026.
Documentation record
Registered dimensions (L × B × D)80.4 ft × 26.2 ft × 9.2 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)80.4 ft × 26.2 ft × 9.2 ft
ITC tonnagegross 162 / net 59
BuilderGRAVOIS BOATS LLC · FRANKLIN, LA, UNITED STATES · built 2017
Hull materialAluminum
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 8 October 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it162 - Convention (Subpart B), Gross Ton
90 - Regulatory (Subpart C or D), Gross Ton
59 - Convention (Subpart B), Net Ton
61 - Regulatory (Subpart C or D), Net Ton
15 - Dead Weight, Ton
52 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 30
31 March 2026
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8333638
25 March 2026
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8331585
1 April 2025
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8103084
27 August 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7990026
20 August 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7985162
26 March 2024
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7883633
15 September 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7792133
28 March 2023
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7658177
13 September 2022
Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7558095
11 September 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7556468
19 May 2022
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7454659
24 March 2022
Internal Structural Exam · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7417789
14 December 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7367792
13 April 2021
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7174553
20 October 2020
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7078584
31 March 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6940193
20 November 2019
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6859404
5 November 2019
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6849384
20 March 2019
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6645986
16 November 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6581904
15 October 2018
Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6761682
23 March 2018
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6377138
22 March 2018
Administrative Inspection · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6376945
18 January 2018
Administrative Inspection · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6339656
17 December 2017
Examination of Repairs · Deficiency Check · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6350695
27 October 2017
Damage Survey · Deficiency Check · Examination of Repairs · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6313900
8 August 2017
Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6234511
26 June 2017
Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6188049
16 May 2017
In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6147156
18 January 2017
Construction Oversight · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6073001
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 March 2024
Resolved
Fresh water pipe for starboard main engine was found damaged and had a tact weld in center of piping section. Piping section needs to be replaced. "(a) Except as otherwise provided in paragraphs (b), (c), (d), and (e) of this section, all engines must be water cooled and meet the requirements of this paragraph. (1) The engine head, block, and exhaust manifold must be water-jacketed and cooled by water from a pump that operates whenever the engine is operating. (2) A suitable hull strainer must be installed in the circulating raw water intake line of an engine cooling water system. (3) A closed fresh water system may be used to cool the engine"
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2024
Resolved 9 April 2024
Resolution: MI inspected the replaced piping on the starboard fresh water piping.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 September 2022
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at a constant marine load. Vessel report a loss of propulsion due to port side engine being rendered inoperable causing an undue risk to the port of New York. In order to clear this deficiency the following actions must be carried out:
1. Provide a causal analysis report on the loss of propulsion and provide a repair proposal for port engine and other affected equipment.
2. Post-approval of repair proposal and upon completion of repairs, provide USCG a tech report delineating all repairs and pier side propulsion test satisfactory.
4. Vessel must undergo an underway sea trial to the satisfaction of an attending marine inspector prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2022
Resolved 13 September 2022
Resolution: MI conducted successful sea trial
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 14 December 2021
Resolved
Operator reported experiencing a loss of propulsion that reduced the maneuverability of the vessel. CG-835V to be cleared upon submission of causal analysis and tech report, list of repairs to be made, and satisfactory completion of a underway sea trial.
46CFR176.840
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 December 2021
Resolved 16 December 2021
Resolution: SPV Branch Chief received satisfactory technician report along with report of satisfactory sea trial. Vessel is cleared to conduct passenger operations.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 16 November 2018
Resolved
Vsl is not broadcasting dimension information (AIS Antenna Position ABCD values equals 0)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 29 March 2022
Resolution: MI witnessed satisfactoy test of AIS
Construction/Loadline › Hull › Hull Plating
Issued 28 November 2017
Resolved
DUE TO THE EXTENSIVE CORROSION IDENTIFIED ON THE H100 SERIES VESSELS, THE VESSEL'S HULL MUST BE MADE AVAILABLE FOR INSPECTION BY A COAST GUARD MARINE INSPECTOR. PRIOR TO STARTING ANY WORK, A REPAIR PROPOSAL SHALL BE SUBMITTED TO THE SECNY OFFICE FOR REVIEW AND APPROVAL. ALL REPAIRS MUST BE CONDUCTED IN ACCORDANCE WITH THE APPROVED REPAIR PLAN, AND INSPECTED BY THE ATTENDING MARINE INSPECTOR.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 December 2017
Resolution: Attened vessel to conduct in-service inspection of all repairs.
Engineering › Electric Propulsion System › Measurement Circuitry
Issued 8 August 2017
Resolved
Vessel's propulsion electronic control system shut down the stbd engine on high fuel pressure. Troubleshoot and repair.
Action required: 705 - Other - as specified
Due 8 August 2017
Resolved 8 August 2017
Resolution: Attended vessel, the operator determined air was present in the fuel line. The filters were replaced and the lines were primed. Conducted sea trials, engine parameters were within normal limits.
Engineering › Lubricating Oil Service System › Valve, Control
Issued 26 June 2017
Resolved
Repair damaged cylinders in STBD engine.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2017
Engineering › Lubricating Oil Service System › Valve
Issued 26 June 2017
Resolved
Conduct sea trials to the satisfaction of attending MI.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2017
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 17 April 2017
Resolved
PROVIDE ACCEPTABLE OVER CURRENT PROTECTION ON THE OUTPUT SIDE OF ALL ACCLAIM LIGHTING DRIVERS/ POWER SUPPLY'S FEEDING ALL ONBOARD LBD LIGHTING
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 June 2017
Resolved 18 May 2017
Resolution: New drivers installed.
Operations/Management › Vessel Safety Management › Company Verification/Review/Evaluation
Issued 17 April 2017
Resolved
CONDUCT NEW TO ZONE INSPECTION PRIOR TO OPERATING TO DETERMINE ZONE SPECIFIC OPERATIONAL CONSTRAINTS AND ROUTE LIMITATIONS
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 18 May 2017
Resolution: Completed NTZ.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 18 January 2017
Resolved
PROVE PROPER OPERATION OF INSTALLED MAGNA LOCK SYSTEM TO INCLUDE WHEN POWER FAILURE OCCURS, THE SYSTEM IS DE-ENERGIZED, ALLOWING ALL DOORS TO OPEN
Action required: 705 - Other - as specified
Resolved 13 November 2020
Resolution: Magna lock system was removed from the whole fleet.
Documentation › Certificates/Documents › Stability Letter
Issued 18 January 2017
Resolved
Vessel needs to have new stability letter onboard prior to operation as per COI.
Action required: 705 - Other - as specified
Due 4 June 2017
Resolved 18 May 2017
Resolution: Vessel has stability letter dated 16MAY2017.