Records from 2016 to 2026. Most recent: inspection, 28 April 2026.
Documentation record
Registered dimensions (L × B × D)80.4 ft × 26.2 ft × 9.2 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)80.4 ft × 26.2 ft × 9.2 ft
ITC tonnagegross 162 / net 59
BuilderHORIZON SHIPBUILDING · Bayou La Batre, AL, UNITED STATES · built 2017
Hull materialAluminum
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 3 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it162 - Convention (Subpart B), Gross Ton
90 - Regulatory (Subpart C or D), Gross Ton
59 - Convention (Subpart B), Net Ton
61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 29
28 April 2026
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8355330
17 March 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8326960
6 May 2025
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8129004
28 February 2025
Administrative Inspection · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8086515
28 February 2025
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8089963
7 May 2024
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7907532
12 March 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7877611
12 December 2023
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7837912
15 September 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7792130
9 May 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7684744
12 May 2022
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7449393
15 March 2022
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7412353
8 June 2021
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7219163
16 March 2021
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7157587
6 July 2020
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7003099
3 June 2020
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6967044
26 May 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6960929
17 March 2020
Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6955214
27 February 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6916815
12 December 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6873309
2 November 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6849396
20 September 2019
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6816493
8 May 2019
Annual Inspection · DAPI Audit
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6679441
9 May 2018
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6409772
9 April 2018
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6540577
27 December 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6329732
27 December 2017
Deficiency Check · In-Service Inspection · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6330001
10 July 2017
Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6207039
8 July 2016
Plan Review "T" Boat · Construction Oversight · Administrative Inspection · Internal Structural Exam · COI Inspection · Initial Certification · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5996652
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 April 2026
Resolved
"Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5 °C (150 °F), must be suitably insulated where necessary to prevent injuries. Lagging on exhaust piping needs replacing.
46CFR177.970
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 May 2026
Resolution: Email has been recieved.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 April 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to:Protect passengers, crew, other persons, and the vessel from electrical hazards. Port controller box was corroded.
46CFR183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 May 2026
Resolution: Email has been recieved.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 April 2026
Resolved
"...Each vessel must carry a certificate with a valid endorsement while subject to the Bridge-to-Bridge Act." Vessel's FCC Bridge to Bridge certificate has a typo, showing the certificate is expired.
47CFR80.1005
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 May 2026
Resolution: Email has been recieved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 May 2025
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load. Vessel ECU's for both port and starboard engines are inoperable, rendering both engines inoperable.
46CFR 182.200(a)
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2025
Resolution: Cleared, recieved tech report, see documents.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 7 May 2024
Resolved
The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. The fuel tank shut off did not close the valve on the port side. Ensure shut off valve works as intended.
46CFR182.455 (b)(4)
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 7 May 2024
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 May 2024
Resolved
Battery chargers must have an ammeter connected in the charging circuit. Both amp meters in port and staboard engine room are inoperable. Ensure ammmeters are working and installed.
46CFR183.350 (f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2024
Resolved 11 June 2024
Resolution: Vessel representative provide electrical one drawings of battery charger ammeter. Pictures of installed ammeter are uploaded under documents as well.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 December 2023
Resolved
Vessel experienced an loss of propulsion on the Starboard Engine on 11Dec2023. Provide causal analysis, repair proposal, and make repairs to the satisfaction of the USCG prior to the carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 December 2023
Resolved 14 December 2023
Resolution: Vessel provided casualty analysis for deficiency. Repairs have been completed and MI's have performed sea trial. Deficiency has been resolved.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 27 February 2020
Resolved
Vessel rep emailed stating IBA's will expire at the end of the month and will not be replaced for an undetermined amount of time. LBS route restricted to operating within 1NM from shore to facilitate continued operation.
Vessel rep will provide pictures and documentation of all serviced IBA's to restore full LBS route.
Action required: 705 - Other - as specified
Resolved 25 March 2020
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 28 December 2017
Resolved
Vessel damaged both propellers running aground. Vessel must repair or replace both propellers. 46CFR176.702
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 December 2017
Resolution: vessel replaced propellers in kind.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 28 December 2017
Resolved
Vessel must replace port shaft & seal. 46CFR176.702
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 December 2017
Resolution: Vessel replaced port shaft and seal in kind.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 28 December 2017
Resolved
Determine cause of 10 amp ground and make proper repairs. Vessel must demonstrate electrical ground is corrected. 46CFR183.200(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 December 2017
Resolution: Vessel ran down ground to a receptacle. Vessel replaced and proved ground to be cleared.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 28 December 2017
Resolved
Vessel must ensure all electrical equipment/fixtures that were submerged in oily water are clean and hazard free. Vessel must prove proper operation of electrical plant. 46CFR183.220
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 December 2017
Resolution: All electrical equipment/fixtures were cleaned and properly operate.
Engineering › Bilge Water Management System › Hose
Issued 28 December 2017
Resolved
Vessel must repair or replace the discharge hose to the portable electrical sub-pump. 46CFR176.830
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 December 2017
Resolution: Vessel replaced hose with new.
Engineering › Bilge Water Management System › Piping
Issued 28 December 2017
Resolved
Vessel has un-authorized nonmetallic piping in a vital system. Vessel must remove plastic piping and repair back to original material previously approved by MSC. 46CFR176.700/182.710
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 December 2017
Resolution: Vessel replaced pipe back to original.
Operations/Management › Vessel Activity › Other
Issued 28 December 2017
Resolved
Vessel must complete an In-Service Inspection following completion of all corrected deficiencies. 46CFR176.702
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 December 2017
Resolution: Vessel completed in service inspection.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 27 December 2017
Resolved
Vessel must follow approved salvage/transit plan and proceed directly to NYACK Shipyard. Vessel must maintain portable sub-pump in the port engine room at all times.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 December 2017
Resolution: Vessel safely arrived at NYACK Shipyard.
Operations/Management › Vessel Activity › Construction/Repair
Issued 27 December 2017
Resolved
Vessel must haul out and make available for inspection by a USCG MArine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 December 2017
Resolution: Vessel hauled out for inspection at NYACK Shipyard.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 30 June 2017
Resolved
Conduct new to zone inspection prior to operating to determine zone specific operational constraints and route limitations.
Condition: Invalid
Due 30 July 2017
Resolved 10 July 2017
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 30 June 2017
Resolved
Prove proper operation of the installed Magna Lock system to include when power failure occurs, the system is de-energized, allowing all doors to open.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 3 June 2020
Resolution: Vessel has removed all magna lock system from vessel