Records from 2016 to 2026. Most recent: inspection, 9 February 2026.
Documentation record
Registered dimensions (L × B × D)543.4 ft × 78.0 ft × 42.0 ft
Registered tonnagegross 11,939 / net 11,939
ITC dimensions (L × B × D)543.4 ft × 78.0 ft × 42.0 ft
ITC tonnagegross 14,001 / net 8,129
BuilderFINCANTIERI BAY SHIPBUILDING COMPANY · STURGEON BAY, WI, UNITED STATES · built 2017
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portWILMINGTON, DE
Trade endorsementsCoastwise, charter, Registry
DocumentationValid · issued 5 December 2025 · expires 31 December 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8129 - Convention (Subpart B), Net Ton
11939 - Regulatory (Subpart C or D), Net Ton
26657 - Dead Weight, Ton
32529 - Displacement, Ton
14001 - Convention (Subpart B), Gross Ton
11939 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 27
9 February 2026
Periodic Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8296263
9 January 2026
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8293868
19 October 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8255168
23 May 2025
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8142172
19 May 2025
Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8139124
21 February 2025
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8064360
8 November 2024
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8032529
4 March 2024
Annual Inspection · MTSA Verification · MARPOL Annex II Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7873669
17 February 2024
Bulk Liquid Transfer Monitor
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7867030
11 March 2023
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7653757
18 November 2022
Examination of Repairs · COI Inspection · In-Service Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7580219
13 October 2022
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7576814
2 May 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7442443
8 February 2022
Annual Inspection · MTSA Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7389052
19 June 2021
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7233117
28 March 2021
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7167682
19 January 2021
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7128754
20 December 2020
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7116356
2 December 2020
MTSA/ISPS Verification · Administrative Inspection · Periodic Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7106116
27 January 2020
Administrative Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6896735
10 January 2020
Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6882307
3 December 2018
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6591311
21 November 2018
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6589230
15 March 2018
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6372962
19 January 2018
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6342058
21 December 2017
Ballast Water Examination · In-Service Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6328150
1 September 2016
Construction Oversight · Administrative Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey · COI Inspection · MARPOL Annex II Examination
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6051440
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 May 2022
Resolved
No extensive repairs to the machinery which affect the safety of the vessel shall be made without the knowledge of the OCMI.
Vessel rep reported the #1 generator has a failed cylinder and injectors.
46 CFR 31.10-25
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 June 2022
Resolved 8 July 2022
Resolution: Generator was overhauled/rebuilt by third party. Tested low lube oil, overspeed and reverse power relay.
Operations/Management › Ballast Water Managment › Ballast Water Discharge
Issued 23 January 2018
Resolved
Notified vessel had onboard untreated ballast water in tanks 1, 4, 6 totaling 4,426.2 m3. Water was loaded in Sturgeon Bay Wisconsin and requested an exchange be conducted more than 12nm from port.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 January 2018
Resolved 23 January 2018
Resolution: COTP authorization for ballast water exemption.
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 12 December 2017
Resolved
The approved ballast water treatment system is not fully operational as required. Make permanent repairs and demonstrate proper operation of the ballast water treatment system (both port and sbtd systems) to the satisfaction of an attending CG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 January 2018
Resolved 3 January 2018
Resolution: Accepted ABS Surveyor's attendance and report indicating proper repair and operation of system.
Operations/Management › Ballast Water Managment › Ballast Water Discharge
Issued 12 December 2017
Resolved
With the ballast water treatment system not being operational the vessel must comply with 33CFR151.2040. The vessel may employ other approved means of ballast water treatment and handling as described in 33CFR151.2025(a). Vessel is to report this condition to each Local COTP for where the vessel operates until this issue is resolved. Until permanent repairs are verified by an attending CG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 January 2018
Resolved 3 January 2018
Resolution: Accepted ABS Surveyor's attendance and report indicating proper repair and operation of system.