Inspection history · 42
23 October 2023
In-Service Inspection · Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7813145
1 April 2021
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7785872
24 February 2021
Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7137494
10 February 2020
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6911573
1 December 2018
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6595663
21 November 2018
Deficiency Check · Initial Certification · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6585418
18 September 2018
In-Service Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6562547
22 September 2015
Industry Initiated Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5726104
28 September 2012
MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4454450
10 May 2010
Industry Initiated Exam · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3734854
25 August 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3576984
14 January 2009
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3394958
26 June 2008
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3295831
14 February 2008
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3150712
9 April 2007
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2904488
9 April 2007
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2904757
30 June 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2703368
6 July 2005
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2416630
5 August 2004
MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2157118
23 June 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2107925
24 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1989431
23 February 2000
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 766197
10 February 2000
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 52371
10 February 2000
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 196572
27 January 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 25021
27 January 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 88074
27 November 1999
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 85131
9 June 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 163163
15 December 1997
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 18270
25 July 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 28071
29 May 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 89626
8 April 1997
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 147662
24 October 1996
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 851855
16 July 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 196573
16 July 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 765853
26 March 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 175485
11 November 1995
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 26720
12 August 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 91827
10 February 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 661969
4 February 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 43111
26 April 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 308539
7 February 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 300298
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 February 2021
Resolved
Propulsion machinery must be maintained to ensure proper operation. Prove proper operation of starboard main engine.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 October 2023
Resolution: Vessel repower/repairs complete 07Sep2023
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 24 February 2021
Resolved
Unable to test steering, as the port flanking rudder has been removed. Prove proper operation of steering system
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 October 2023
Resolution: Vessel repower/repairs complete 07Sep2023
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 February 2021
Resolved
Unable to determine fire pump pressure due to wasted gauge
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 October 2023
Resolution: Vessel repower/repairs complete 07Sep2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 February 2021
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Measures must be in place to prevent flammable or combustible liquid piping leaks from coming into contact with these components. Replace missing lagging on port generator and port main engine exhaust.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 October 2023
Resolution: Vessel repower/repairs complete 07Sep2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 February 2021
Resolved
Secure flame locker in engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 October 2023
Resolution: Flammable storage locker removed from engine room.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 February 2021
Resolved
Flammable liquids in engine room must be stored in the flame locker.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 October 2023
Resolution: Flammable liquids properly stowed
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 February 2021
Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no opening in the sides or bottoms. Remove plastic garbage can from the engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 October 2023
Resolution: Plastic garbage can removed from engine room
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 February 2021
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following:
(a) All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Remove liquid and fuel from bilges.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 October 2023
Resolution: Liquid and fuel removed from bilges
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 24 February 2021
Resolved
Renew/replace forward deck light bracket that is broken and hanging by twine.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 October 2023
Resolution: Forward deck light sat
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 24 February 2021
Resolved
Renew/replace gaskets on watertight doors throughout the vessel
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 November 2023
Resolution: Gaskets renewed
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 24 February 2021
Resolved
Renew/replace door handle on 2nd deck door, as the door handle is missing and being held open with a tie-back.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 October 2023
Resolution: Door handle replaced
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 February 2020
Resolved
Each towing vessel must have a bilge alarm that has an audible and visible signal at the operating station. When tested, the bilge alarm did not alarm at the operating station. Repair so alarm has both audible and visual signal.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2020
Resolved 24 October 2023
Resolution: Both audible and visual signals operable at the operating station
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 10 February 2020
Resolved
Electrical systems and equipment must minimize fire and shock hazards. Found exposed wiring coming out of the bulkhead in the 2 staterooms on the 2nd deck. Properly secure wiring to minimize shock hazard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2020
Resolved 24 October 2023
Resolution: Wiring properly secured
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 February 2020
Resolved
Each type I lifejacket must be marked with the name of the vessel. Found type I lifejackets without markings. Mark as required.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 20 February 2020
Resolution: Corrected while on board.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 February 2020
Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires. The fire detection indicator panel in the pilothouse only allows silencing of alarms without allowing a reset unless vessel power is shutdown. Once the panel is silenced, if a fire in the same space triggers the alarm, it will not sound.
Ensure panel in pilothouse is able to reset detection system to enable repeat fire detection alerts/alarms.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 February 2021
Resolution: Fire detection system alarming properly
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 November 2018
Resolved
Prove proper operation of audible and visual alarms in machinery space.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 10 February 2020
Resolution: Cleared during inspection
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 21 November 2018
Resolved
Remove diesel in bilges to eliminate fire hazard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 10 February 2020
Resolution: Cleared during 10Feb20 inspection
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 21 November 2018
Resolved
Install new oil discharge placard in engine room; old placard painted over on foward bulkhead of upper level of machinery space.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 10 February 2020
Resolution: Cleared during 10Feb20 inspection
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 November 2018
Resolved
Install rubber mat in way of electrical panels on forward bulkhead of machinery space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 10 February 2020
Resolution: Cleared during 10Feb20 inspection
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 21 November 2018
Resolved
Implement lock-out/tag-out procedures on equipment in machinery space that is under repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 10 February 2020
Resolution: Cleared during 10Feb20 inspection
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 November 2018
Resolved
Repair all loose and dead-end wiring throughout the vessel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 10 February 2020
Resolution: Cleared during 10Feb20 inspection
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 November 2018
Resolved
Ensure sufficient retro-reflective material is applied to all Type I PFDs.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 10 February 2020
Resolution: Cleared during 10Feb20 inspection
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 21 November 2018
Resolved
Label all deck hatches that access fuel tanks.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 10 February 2020
Resolution: Cleared during 10Feb20 inspection
03 - Water/Weathertight Conditions › N/A - No Subsystem › Overloading
Issued 21 November 2018
Resolved
Remove excess water in all voids throughout the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 10 February 2020
Resolution: Cleared during 10Feb20 inspection
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 November 2018
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 10 February 2020
Resolution: Cleared during 10Feb20 inspection
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 November 2018
Resolved
Provide FCC Safety Radio certificate and VHF-Bridge-to-Bridge certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 10 February 2020
Resolution: Cleared during 10Feb20 inspection
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 21 November 2018
Resolved
Prove proper operation of AIS.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 10 February 2020
Resolution: Cleared during inspection
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 November 2018
Resolved
Apply for EPA Vessel General Permit.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 7 January 2019
Resolution: Operator applied for EPA Vessel General Permit.
Engineering › Steering Gear System › Valve
Issued 9 April 2007
Resolved
Faulty pressure relief valve resulting in loss of hydraulic pressure.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2007
Resolved 9 April 2007
Resolution: Replaced old pressure valve with new valve, system works well, all sat.
Accommodation/Occupational Safety
Issued 26 April 1986
Resolved
THE VESSEL'S TYPE III MARINE SANITATION DEVICE WAS FILLED BEYOND CAPACITY ALLOWING RAW SEWAGE TO BE DISCHARGED DIRECTLY IN THE WATER THROUGH THE VENT PIPE IN VIOLATION OF 33CFR159.7(C).
Condition: Unknown
Due 26 April 1986
Resolved 26 April 1986
Fire Fighting
Issued 7 February 1985
Resolved
46CFR25.30-20 FIRE EXTINGUISHERS NOT CHECKED OR PROPER QUANITY. VESSEL NEEDS ONE BII FIRE EXTINGUISHER
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985