BAILEY MATTHEW

Built
1976
Last inspected
23 October 2023
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 23 October 2023
…with no type recorded27
Operational controls None recorded without a removal date
Years with a record 23 calendar years (1985–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK5686
142015
Flag
UNITED STATES
Maury page id
psix-142015

Documentation record

Registered dimensions (L × B × D)62.4 ft × 24.0 ft × 8.6 ft
Registered tonnagegross 123 / net 83
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWALL SHIPYARD · HARVEY, LA, UNITED STATES · built 1976
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPITTSBURGH, PA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 5 January 2026 · expires 31 January 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it123 - Regulatory (Subpart C or D), Gross Ton
83 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 42 inspections, each with its date, unit and type; 31 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 15 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 15

Inspection history · 42

23 October 2023 In-Service Inspection · Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7813145
1 April 2021 Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7785872
24 February 2021 Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7137494
10 February 2020 MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6911573
1 December 2018 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6595663
21 November 2018 Deficiency Check · Initial Certification · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6585418
18 September 2018 In-Service Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6562547
22 September 2015 Industry Initiated Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5726104
28 September 2012 MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4454450
10 May 2010 Industry Initiated Exam · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3734854
25 August 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3576984
14 January 2009 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3394958
26 June 2008 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3295831
14 February 2008 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3150712
9 April 2007 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2904488
9 April 2007 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2904757
30 June 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2703368
6 July 2005 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2416630
5 August 2004 MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2157118
23 June 2004 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2107925
24 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1989431
23 February 2000 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 766197
10 February 2000 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 52371
10 February 2000 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 196572
27 January 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 25021
27 January 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 88074
27 November 1999 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 85131
9 June 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 163163
15 December 1997 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 18270
25 July 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 28071
29 May 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 89626
8 April 1997 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 147662
24 October 1996 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 851855
16 July 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 196573
16 July 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 765853
26 March 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 175485
11 November 1995 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 26720
12 August 1994 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 91827
10 February 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 661969
4 February 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 43111
26 April 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 308539
7 February 1985 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 300298

Deficiency record · 31

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 February 2021 Resolved
Propulsion machinery must be maintained to ensure proper operation. Prove proper operation of starboard main engine.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 October 2023
Resolution: Vessel repower/repairs complete 07Sep2023
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 24 February 2021 Resolved
Unable to test steering, as the port flanking rudder has been removed. Prove proper operation of steering system
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 October 2023
Resolution: Vessel repower/repairs complete 07Sep2023
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 February 2021 Resolved
Unable to determine fire pump pressure due to wasted gauge
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 October 2023
Resolution: Vessel repower/repairs complete 07Sep2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 February 2021 Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Measures must be in place to prevent flammable or combustible liquid piping leaks from coming into contact with these components. Replace missing lagging on port generator and port main engine exhaust.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 October 2023
Resolution: Vessel repower/repairs complete 07Sep2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 February 2021 Resolved
Secure flame locker in engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 October 2023
Resolution: Flammable storage locker removed from engine room.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 February 2021 Resolved
Flammable liquids in engine room must be stored in the flame locker.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 October 2023
Resolution: Flammable liquids properly stowed
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 February 2021 Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no opening in the sides or bottoms. Remove plastic garbage can from the engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 October 2023
Resolution: Plastic garbage can removed from engine room
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 February 2021 Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following: (a) All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Remove liquid and fuel from bilges.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 October 2023
Resolution: Liquid and fuel removed from bilges
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 24 February 2021 Resolved
Renew/replace forward deck light bracket that is broken and hanging by twine.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 October 2023
Resolution: Forward deck light sat
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 24 February 2021 Resolved
Renew/replace gaskets on watertight doors throughout the vessel
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 November 2023
Resolution: Gaskets renewed
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 24 February 2021 Resolved
Renew/replace door handle on 2nd deck door, as the door handle is missing and being held open with a tie-back.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 October 2023
Resolution: Door handle replaced
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 February 2020 Resolved
Each towing vessel must have a bilge alarm that has an audible and visible signal at the operating station. When tested, the bilge alarm did not alarm at the operating station. Repair so alarm has both audible and visual signal.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2020
Resolved 24 October 2023
Resolution: Both audible and visual signals operable at the operating station
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 10 February 2020 Resolved
Electrical systems and equipment must minimize fire and shock hazards. Found exposed wiring coming out of the bulkhead in the 2 staterooms on the 2nd deck. Properly secure wiring to minimize shock hazard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2020
Resolved 24 October 2023
Resolution: Wiring properly secured
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 February 2020 Resolved
Each type I lifejacket must be marked with the name of the vessel. Found type I lifejackets without markings. Mark as required.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 20 February 2020
Resolution: Corrected while on board.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 February 2020 Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires. The fire detection indicator panel in the pilothouse only allows silencing of alarms without allowing a reset unless vessel power is shutdown. Once the panel is silenced, if a fire in the same space triggers the alarm, it will not sound. Ensure panel in pilothouse is able to reset detection system to enable repeat fire detection alerts/alarms.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 February 2021
Resolution: Fire detection system alarming properly
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 November 2018 Resolved
Prove proper operation of audible and visual alarms in machinery space.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 10 February 2020
Resolution: Cleared during inspection
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 21 November 2018 Resolved
Remove diesel in bilges to eliminate fire hazard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 10 February 2020
Resolution: Cleared during 10Feb20 inspection
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 21 November 2018 Resolved
Install new oil discharge placard in engine room; old placard painted over on foward bulkhead of upper level of machinery space.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 10 February 2020
Resolution: Cleared during 10Feb20 inspection
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 November 2018 Resolved
Install rubber mat in way of electrical panels on forward bulkhead of machinery space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 10 February 2020
Resolution: Cleared during 10Feb20 inspection
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 21 November 2018 Resolved
Implement lock-out/tag-out procedures on equipment in machinery space that is under repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 10 February 2020
Resolution: Cleared during 10Feb20 inspection
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 November 2018 Resolved
Repair all loose and dead-end wiring throughout the vessel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 10 February 2020
Resolution: Cleared during 10Feb20 inspection
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 November 2018 Resolved
Ensure sufficient retro-reflective material is applied to all Type I PFDs.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 10 February 2020
Resolution: Cleared during 10Feb20 inspection
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 21 November 2018 Resolved
Label all deck hatches that access fuel tanks.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 10 February 2020
Resolution: Cleared during 10Feb20 inspection
03 - Water/Weathertight Conditions › N/A - No Subsystem › Overloading
Issued 21 November 2018 Resolved
Remove excess water in all voids throughout the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 10 February 2020
Resolution: Cleared during 10Feb20 inspection
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 November 2018 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 10 February 2020
Resolution: Cleared during 10Feb20 inspection
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 November 2018 Resolved
Provide FCC Safety Radio certificate and VHF-Bridge-to-Bridge certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 10 February 2020
Resolution: Cleared during 10Feb20 inspection
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 21 November 2018 Resolved
Prove proper operation of AIS.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 10 February 2020
Resolution: Cleared during inspection
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 November 2018 Resolved
Apply for EPA Vessel General Permit.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 7 January 2019
Resolution: Operator applied for EPA Vessel General Permit.
Engineering › Steering Gear System › Valve
Issued 9 April 2007 Resolved
Faulty pressure relief valve resulting in loss of hydraulic pressure.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2007
Resolved 9 April 2007
Resolution: Replaced old pressure valve with new valve, system works well, all sat.
Accommodation/Occupational Safety
Issued 26 April 1986 Resolved
THE VESSEL'S TYPE III MARINE SANITATION DEVICE WAS FILLED BEYOND CAPACITY ALLOWING RAW SEWAGE TO BE DISCHARGED DIRECTLY IN THE WATER THROUGH THE VENT PIPE IN VIOLATION OF 33CFR159.7(C).
Condition: Unknown
Due 26 April 1986
Resolved 26 April 1986
Fire Fighting
Issued 7 February 1985 Resolved
46CFR25.30-20 FIRE EXTINGUISHERS NOT CHECKED OR PROPER QUANITY. VESSEL NEEDS ONE BII FIRE EXTINGUISHER
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985

Recorded names · 1

STALLION (2006–2009). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.