TIGRE is a 1976 towing vessel. The Coast Guard has recorded 24 inspections since 1995, most recently in March 2026, along with 22 deficiencies and 2 casualty investigations between 2005 and 2013.

Records from 1995 to 2026. Most recent: inspection, 18 March 2026.

Built
1976
Last inspected
18 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 18 March 2026
…with no type recorded12
Operational controls None recorded without a removal date
Years with a record 17 calendar years (1995–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK5655
142594
Flag
UNITED STATES
Maury page id
psix-142594

Documentation record

Registered dimensions (L × B × D)57.0 ft × 22.0 ft × 8.1 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSTEPHENSVILLE, LA, UNITED STATES · built 1976
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portDUBUQUE, IA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 May 2026 · expires 30 June 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ALLISON MARIE Towing Vessel · MISLE 206389 · 2 December 2013 · activity 4762747JEFFREY G Tank Barge · MISLE 52745 · 2 December 1999 · activity 113610DALE CATHORALL Towing Vessel · MISLE 72115 · 2 December 1999 · activity 113610

Inspection history · 24

18 March 2026 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8329345
27 October 2025 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 8258124
1 April 2025 Administrative Inspection · Periodic Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 8103863
22 December 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7862293
2 February 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7620016
10 December 2021 Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7366088
13 July 2020 Initial Certification · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7006931
23 April 2015 Industry Initiated Exam
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5112666
2 December 2013 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4762747
30 August 2012 Administration
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4426002
15 February 2012 Industry Initiated Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4243564
7 March 2011 Deficiency Check · Industry Initiated Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3959143
25 March 2008 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 3172995
16 May 2005 Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 2485258
25 September 2000 Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 282608
2 December 1999 Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 113610
2 December 1999 Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 216836
29 January 1999 Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 214999
13 May 1998 Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 415915
21 March 1998 Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 414158
15 August 1997 Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 407326
3 November 1996 Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 457682
24 November 1995 Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 60372
19 April 1995 Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 377554

Deficiency record · 22

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 March 2026 Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. Fuel leak was identified in machinery space originating at the sight glass on the starboard side of the fuel tank. 46 CFR 143.220
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 18 March 2026
Resolved 3 April 2026
Resolution: Operator repaired sight glass and cleaned leak.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 March 2026 Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Machinery space bilge contained an excessive amount of fuel. 46 CFR 142.220
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 18 March 2026
Resolved 3 April 2026
Resolution: Operator cleaned bilges.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 2 February 2023 Resolved
The master of a towing vessel must ensure that each crewmember participates in fire-fighting drills and receives instruction at least once each month. Found gaps in drills log. Instructed crew to log drills conducted during inspection.
Action required: 10 - Deficiency Rectified
Due 3 February 2023
Resolved 3 February 2023
Resolution: Crew logged inspection drills.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 February 2023 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Found breaker panel in engine room had missing door latch. Crew installed latching mechanism.
Action required: 10 - Deficiency Rectified
Due 3 February 2023
Resolved 3 February 2023
Resolution: Crew installed latching mechanism.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 February 2023 Resolved
Unless otherwise specified, all lifesaving equipment must be approved by the Commandant under the approval series specified in each section. Inspection found non-SOLAS reflective tape on life ring. Crew removed life ring. Vessel still has required number of life rings.
Action required: 10 - Deficiency Rectified
Due 3 February 2023
Resolved 3 February 2023
Resolution: Crew removed lifering as excess gear. Vessel has required number of liferings.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 February 2023 Resolved
All fire-detection systems must be inspected or tested at least once every 12 months. Prove to the attending inspector that the fire detection system has had annual servicing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2023
Resolution: Company provided fire servicing report.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 December 2021 Resolved
Power supply batteries for alarms and emergency lights must be tested every three months. There is no record of testing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 January 2022
Resolved 14 February 2022
Resolution: POC provided form for documentation.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 15 December 2021 Resolved
Each new crew member must receive a safety orientation. No records are available.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 January 2022
Resolved 25 February 2022
Resolution: Received document via email sufficient to clear def.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 15 December 2021 Resolved
Vessel must have an illuminated magnetic compass or swing meter. No compass or swing meter was installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 January 2022
Resolved 22 February 2022
Resolution: Received email containing photos sufficient to clear deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 December 2021 Resolved
Portable fire extinguishers must be Coast Guard approved and used with appropriate brackets. Multiple brackets were not approved type.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 January 2022
Resolved 14 February 2022
Resolution: All portable fire extinguishers were in approved brackets.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 December 2021 Resolved
Fire detection panel must be tested at least every 12 months. No testing was documented.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 January 2022
Resolved 14 February 2022
Resolution: Testing report provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 December 2021 Resolved
Machinery and electrical systems must be maintained to provide for safe operation. Hot water heater is not securely mounted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 January 2022
Resolved 14 February 2022
Resolution: Resolved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 December 2021 Resolved
A remote fuel shutoff valve must be installed in the fuel piping directly outside of a fuel tank. Valves are not in correct location.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 January 2022
Resolved 14 February 2022
Resolution: Shut off valve installed just outside of fuel tank.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 December 2021 Resolved
A towing vessel must undergo an annual inspection within 3 months before or after the COI anniversary. The COI anniversary date is September 4, 2021 and, to date, the vessel has not undergone an annual inspection. Vessel is prohibited from any operations previously authorized by the COI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2021
Resolution: Conducted COI exam.
Engineering
Issued 25 September 2000 Resolved
STBD gerator must have a protective guard over the pulley system.
Condition: Unknown
Due 27 September 2000
Resolved 27 September 2000
Electrical
Issued 25 September 2000 Resolved
All lights must have proper protective coverings
Condition: Unknown
Due 27 September 2000
Resolved 27 September 2000
Lifesaving
Issued 25 September 2000 Resolved
USCG approved life ring must be immediately availabe to throw, fabricate a mounting device.
Condition: Unknown
Due 27 September 2000
Resolved 27 September 2000
Fire Fighting
Issued 21 March 1998 Resolved
VESSEL'S FIRE EXTINGUISHERS NEED ANNUAL SERVICING.
Condition: Unknown
Due 13 May 1998
Resolved 13 May 1998
Documentation
Issued 15 August 1997 Resolved
VESSEL HAD NO TRANSFER PROCEDURES.
Condition: Unknown
Due 27 March 1998
Resolved 27 March 1998
Navigation
Issued 15 August 1997 Resolved
VESSEL WAS MISSING LOCAL NOTICE TO MARINERS.
Condition: Unknown
Due 27 March 1998
Resolved 27 March 1998
Navigation
Issued 15 August 1997 Resolved
VESSEL'S STERNLIGHT AND TOW LIGHTS WEREN'T OPERATIONAL.
Condition: Unknown
Due 13 May 1998
Resolved 13 May 1998
Navigation
Issued 15 August 1997 Resolved
VESSEL WAS MISSING MAGNETIC COMPASS.
Condition: Unknown
Due 27 March 1998
Resolved 27 March 1998

Casualty record · 2

16 May 2005Routine · role: Involved in a Marine Casualty · activity 2485258
2 December 2013Routine · role: Involved in a Marine Casualty · activity 4762747