Records from 2017 to 2026. Most recent: inspection, 9 June 2026.
Documentation record
Registered dimensions (L × B × D)137.3 ft × 39.4 ft × 13.0 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)137.3 ft × 39.4 ft × 13.0 ft
ITC tonnagegross 726 / net 261
BuilderGULF CRAFT LLC · FRANKLIN, LA, UNITED STATES · built 2018
Hull materialAluminum
PropulsionJet Drive
Hull shapeShip
Hull configurationTwin Hull
Hailing portATLANTIC HIGHLANDS, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it726 - Convention (Subpart B), Gross Ton
99 - Regulatory (Subpart C or D), Gross Ton
261 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
9 June 2026
Annual Inspection · MSP Additional Oversight - Risk Assessment · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8395166
2 December 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8274882
10 June 2025
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8156558
17 July 2024
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7958485
12 December 2023
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7837678
24 October 2023
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7813740
5 May 2023
Administrative Inspection · Internal Structural Exam · Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7676107
11 February 2023
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7635341
10 February 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7638252
19 June 2022
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7483003
5 June 2021
Damage Survey · Internal Structural Exam · Drydock Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7216659
5 June 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7219151
1 December 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7105761
11 August 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7029777
4 May 2020
Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6947898
16 July 2019
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6751014
16 May 2018
In-Service Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6434751
15 September 2017
Construction Oversight · Initial Certification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6267139
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 June 2026
Resolved
Penetrations in A-Class fire control boundaries for electrical cables, pipes, trunks, ducts, etc. must be constructed to prevent the passage of flame and smoke for one hour. In addition, the penetration must be designed or insulated so that it will withstand the same temperature rise limits as the boundary penetrated.
MI observed wire penetration in port side lazarette with no fire stop. Secure penetration to the satisfaction of MI.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 June 2026
Resolved 16 June 2026
Resolution: Operator sent photo of fire block.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 June 2026
Resolved
The following spaces must be equipped with a fire detection and alarm system of an approved type that is installed in accordance with part 76 in subchapter H of this chapter, except when a fixed gas fire extinguishing system that is capable of automatic discharge upon heat detection is installed or when the space is manned:(1) A space containing propulsion machinery.
MI observed inoperable smoke detector in starboard side engine room. Fix smoke detector to the satisfaction of MI.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 June 2026
Resolved 10 June 2026
Resolution: Fire detection reconnected and confirmed with panel
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 June 2025
Resolved
Replace the bracket holding the Forward, STBD Portable Fire Extinguisher. The current bracket does not secure the extinguisher.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2025
Resolved 20 June 2025
Resolution: Vessel submitted photographic evidance of newly installed bracket.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 June 2025
Resolved
MIs observed vessel was unable to activate the port generator fuel shut off valve. Vessel repaired shutoff valve and was unable to secure.
Action required: 10 - Deficiency Rectified
Resolved 11 June 2025
Resolution: Vessel repaired the shutoff valve and was able to show repairs to MIs
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 June 2025
Resolved
Port Side Indicator Light for NOVEK (Fire Suppression System) did not illuminate. Fix w/ in 7 days.
Action required: 705 - Other - as specified
Due 18 June 2025
Resolved 20 June 2025
Resolution: Vessel repaired indicator light for Fixed Fire supression syste.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 October 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load.
Vessel reported that STBD side #4 transmission needed to be serviced, therefore, the transmission must be replaced. Replace transmission in kind and make repairs IAW approved repair plan. Conduct satisfactory sea trial in the presence of a Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2023
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 May 2023
Resolved
Penetrations [in fire control boundaries] must be designed or insulated so that it will withstand the same temperature rise limits as the boundary penetrated.
Two cable runs through the aftmost bulkhead in the fuel tank void, port side, lacked appropriate fire stop filling.
46 CFR 116.415, 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2023
Resolved 24 May 2023
Resolution: Resolved via pictures, uploaded.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 5 May 2023
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the cognizant OCMI.
The bracket for the portable fire extinguisher located on main deck port side forward near door was broken.
46 CFR 118.600, 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2023
Resolved 24 May 2023
Resolution: Resolved via pictures, uploaded.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 5 May 2023
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2023
Resolved 24 May 2023
Resolution: Resolved via pictures, uploaded.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 May 2023
Resolved
Suitable means, such as a manual damper, automatic damper, or vent cover, must be provided in an accessible location outside the space served by the ventilation duct for shutting off the passage of air through the ventilation duct in the event of fire.
Two dampers in port engine room failed to close fully upon initial testing. Rectified on the spot.
46 CFR 116.610(d), 10c
Action required: 10 - Deficiency Rectified
Resolved 5 May 2023
Resolution: Corrected on the spot
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 11 February 2023
Resolved
VSL ran aground. VSL to provide damage assesment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2023
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 5 June 2021
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Vessel ran a ground due to loss of steering, breaching the port engine room, port fuel void, and possible other spaces. Provide a salvage plan and tow plan prior to movement of vessel to Sector New York VTS.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 7 June 2021
Resolved 19 June 2022
Resolution: Complete.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 June 2021
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel experenced loss of manuberibility and speed control. Provide cause of failure report prior to carring passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 June 2021
Resolved 19 June 2022
Resolution: The investigation has been completed and a cause of failure has been determined.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 August 2020
Resolved
Penetrations in B-Class fire control boundaries for must be constructed to prevent the passage of flame for 30 minutes. STBD FWD window main deck adjacent to FWD passenger refuge area cracked, STBD window behind passenger embarkation area cracked. Replace windows within 30 days.
Action required: 705 - Other - as specified
Due 25 September 2020
Resolved 28 September 2020
Resolution: Received pictures confirmation of windows being replaced. Email uploaded as PDF.
Operations/Management › Drills/Instruction › Fire
Issued 4 May 2018
Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that a fire drill be held under simulated emergency conditions to be specified by the inspector. Once the vessel has arrived in New York OCMI zone, they shall coordinate with the local Coast Guard Office to perform a fire drill with the crew operating the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2018
Resolved 16 May 2018
Resolution: Completed drills with crew, all sat.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 4 May 2018
Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship drill or man overboard drill be held under simulated emergency conditions to be specified by the inspector. Once the vessel has arrived in New York OCMI zone, they shall coordinate with the local Coast Guard Office to perform a fire drill with the crew operating the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2018
Resolution: Completed drills with crew, all sat.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 4 May 2018
Resolved
Design Verification and Periodic Safety test procedure (DVTP) documents approve by the Coast Guard must be retained onboard the vessel. The vessel must obtain a final approve copy of the DVTPs
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 July 2018
Resolution: MSC issued final approval letter.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 4 May 2018
Resolved
All electrical installation plans shall be submitted by the owner of a vessel rquesting initial inspection for certification. These plans shall be approve by USCG Marine Safety Center (MSC). The vessel has one outstanding comment waiting for approval from MSC. See MSC letter, serial number: E2-1800996.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 July 2018
Resolution: MSC Issued final approval letter.